FCC ID 2AQV3-GEM100
Point of care Whole Blood Microcoagulation System with WLAN functionality
by Accriva Diagnostics
Grantee Code: 2AQV3 Product Code: GEM100
Latest application date: 2018-11-05
Documents for this grantee are blocked from local display. Public filing metadata and document detail pages remain available, with links to the FCC attachment forwarder and document sources.
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2018-11-05 |
| 2412-2462 MHz | Original Equipment | 2018-11-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual Privacy/DMCA removed | Users Manual | 2019-05-01 | PDF 3.8 MB |
| Usermanual Blocked | Users Manual | 2019-05-01 | PDF 3.8 MB |
| Internal Photos Blocked | Internal Photos | 2019-05-01 | PDF 634 KB |
| External Photos Blocked | External Photos | 2019-05-01 | PDF 761.4 KB |
| External photos Blocked | External Photos | 2019-05-01 | PDF 761.4 KB |
| Label Blocked | ID Label/Location Info | 2018-11-05 | PDF 76.9 KB |
| Label Location Blocked | ID Label/Location Info | 2018-11-05 | PDF 96.8 KB |
| SAR Test Setup Photos Blocked | Test Setup Photos | 2019-05-01 | PDF 247.9 KB |
| Test Setup Photos Blocked | Test Setup Photos | 2019-05-01 | PDF 269.3 KB |
| SAR Test Report Metadata only | Test Report | 2018-11-05 | PDF 5.1 MB |
| SAR Test Report Blocked | RF Exposure Info | 2018-11-05 | PDF 5.1 MB |
| SAR test report Blocked | RF Exposure Info | 2018-11-05 | PDF 5.1 MB |
| Test Report Blocked | Test Report | 2018-11-05 | PDF 2.8 MB |
| Test Report I Blocked | Test Report | 2018-11-05 | PDF 4 MB |
| Test Report II Part 1 Blocked | Test Report | 2018-11-05 | PDF 1.4 MB |
| Test Report II Part 2 Blocked | Test Report | 2018-11-05 | PDF 1.9 MB |
| Test Report II Part 3 Blocked | Test Report | 2018-11-05 | PDF 2 MB |
| Test Report II Part 4 Blocked | Test Report | 2018-11-05 | PDF 1.5 MB |
| Test Report II Part 5 Blocked | Test Report | 2018-11-05 | PDF 1.9 MB |
| Test Report II Part 6 Blocked | Test Report | 2018-11-05 | PDF 1.4 MB |
| Test Report II Part 7 Blocked | Test Report | 2018-11-05 | PDF 2 MB |
| Confidentiality Letter Blocked | Cover Letter(s) | 2018-11-05 | PDF 134 KB |
| Block Diagram Metadata only | Block Diagram | PDF 241.1 KB | |
| Schematics I Metadata only | Schematics | PDF 5.1 MB | |
| Schematics II Metadata only | Schematics | PDF 135.8 KB | |
| Operating Description 1 Metadata only | Operational Description | PDF 99.7 KB | |
| Operating Description 2 Metadata only | Operational Description | PDF 339.2 KB | |
| Operating Description 3 Metadata only | Operational Description | PDF 30.3 KB | |
| Operating Description 4 Metadata only | Operational Description | PDF 1 MB | |
| Part List 1 Metadata only | Parts List/Tune Up Info | PDF 14.3 KB | |
| Part List 2 Metadata only | Parts List/Tune Up Info | PDF 12.6 KB | |
| Part List 3 Metadata only | Parts List/Tune Up Info | PDF 54.4 KB | |
| Part List 4 Metadata only | Parts List/Tune Up Info | PDF 24.6 KB | |
| Tune Up Metadata only | Parts List/Tune Up Info | PDF 177 KB |
Application Information
| Application ID | szMeOVw659uMuHFjSaNu4g== |
|---|---|
| Final Action Date | 2018-11-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027765122 |
| Model | GEM100 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Point of care Whole Blood Microcoagulation System with WLAN functionality |
| Responsible Party | Thomas J Vaccaro, Principal R&D; Systems Engineer, tvaccaro@ilww.com |
| Test Firm | Mac Elliott, TUV SUD America Inc., William.Elliott@tuvsud.com |
| TCB Email | vina.kerai@tuvsud.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 05/01/2019 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 1.02 W/kg and 1.45 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| szMeOVw659uMuHFjSaNu4g== | 2018-11-05 | Original Equipment |
| 9kWno1a3j58dX+tge7QbqA== | 2018-11-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application szMeOVw659uMuHFjSaNu4g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 11/05/2018 Application Dated: 11/05/2018 |
| Accriva Diagnostics |
| 6260 Sequence Drive |
| SAN DIEGO, CA 92121 |
| Attention: Thomas Vaccaro , Principal R&D Systems Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQV3-GEM100 |
| Name of Grantee: | Accriva Diagnostics |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Point of care Whole Blood Microcoagulation System with WLAN functionality |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.028 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.028 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.039 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.039 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.053 | ||
| CC MO ND | 15E | 5510.0 - 5710.0 | 0.053 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.042 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.042 |
| Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 1.02 W/kg and 1.45 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application szMeOVw659uMuHFjSaNu4g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Accriva Diagnostics 6260 Sequence Drive SAN DIEGO, CA 92121 United States |
Date of Grant: 11/05/2018 Application Dated: 11/05/2018 |
| Attention: Thomas Vaccaro , Principal R&D Systems Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQV3-GEM100 |
| Name of Grantee: | Accriva Diagnostics |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Point of care Whole Blood Microcoagulation System with WLAN functionality |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.028 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.028 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.039 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.039 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.053 | ||
| CC MO ND | 15E | 5510.0 - 5710.0 | 0.053 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.042 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.042 |
| Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 1.02 W/kg and 1.45 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 11/05/2018 Application Dated: 11/05/2018 |
| Accriva Diagnostics |
| 6260 Sequence Drive |
| SAN DIEGO, CA 92121 |
| Attention: Thomas Vaccaro , Principal R&D Systems Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQV3-GEM100 |
| Name of Grantee: | Accriva Diagnostics |
| Equipment Class: | Digital Transmission System |
| Notes: | Point of care Whole Blood Microcoagulation System with WLAN functionality |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.108 |
| Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 0.81 W/kg and 1.45 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 9kWno1a3j58dX+tge7QbqA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Accriva Diagnostics 6260 Sequence Drive SAN DIEGO, CA 92121 United States |
Date of Grant: 11/05/2018 Application Dated: 11/05/2018 |
| Attention: Thomas Vaccaro , Principal R&D Systems Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQV3-GEM100 |
| Name of Grantee: | Accriva Diagnostics |
| Equipment Class: | Digital Transmission System |
| Notes: | Point of care Whole Blood Microcoagulation System with WLAN functionality |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.108 |
| Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 0.81 W/kg and 1.45 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |