FCC ID 2AQYP-TRACK1100

TRACK1100

by Sensolus NV

Grantee Code: 2AQYP   Product Code: TRACK1100
Latest application date: 2022-06-08

FCC ID Device Details

FCC ID2AQYP-TRACK1100
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AQYP
Product CodeTRACK1100
Applicant BusinessSensolus NV 🇧🇪
Related Domains sensolus.com
Equipment ClassTRACK1100
Test FirmBureau Veritas CPS(H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-06-08
699.2-715.8 MHzOriginal Equipment2022-06-08

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2022-06-08PDF 170.1 KB
Users manualUsers Manual2022-06-08PDF 170.1 KB
Internal photosInternal Photos2022-06-08PDF 1.1 MB
External photosExternal Photos2022-06-08PDF 471.1 KB
Label Location revID Label/Location Info2022-06-08PDF 256.4 KB
Label SampleID Label/Location Info2022-06-08PDF 1.4 MB
Test setup photos revTest Setup Photos2022-06-08PDF 2.5 MB
Test Report (DTS-BTLE)Test Report2022-06-08PDF 626.9 KB
Test Report (PCB-Part 27) Part 1 rev2Test Report2022-06-08PDF 5.8 MB
Test Report (PCB-Part 27) Part 2 rev2Test Report2022-06-08PDF 3.3 MB
Test report (PCB-Part 24) rev2Test Report2022-06-08PDF 4.9 MB
Confidentiality Request (Long term)Cover Letter(s)2022-06-08PDF 113.1 KB
Confidentiality request(Long term)Cover Letter(s)2022-06-08PDF 113.1 KB
Cover Letter (Agent Authorization)Cover Letter(s)2022-06-08PDF 128 KB
RF Exposure Info (MPE) rev2RF Exposure Info2022-06-08PDF 174.6 KB
RF exposure info (MPE) rev2RF Exposure Info2022-06-08PDF 174.6 KB
Block diagram Metadata onlyBlock DiagramPDF 569.3 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 592.3 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 405.1 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 128.6 KB

Application Information

Application IDrZZoeqcaSTGKwtxsZDZHEg==
Final Action Date2022-06-08
Application PurposeOriginal Equipment
Applicant FRN0027786722
ModelTRACK1100
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionTRACK1100
Responsible PartyKoen Van Vlaenderen, HW Lead / Co-Fouder, koen@sensolus.com , +32486929594
AgentAndrea Andrea Andrea, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, andrea.hsia@bureauveritas.com , 886-3-264-1628
Test FirmEric Lin, Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch, eric-wp.lin@tw.bureauveritas.com , +886-3-2641570
TCB Emailcertification@nacsemc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is maximum conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
rZZoeqcaSTGKwtxsZDZHEg==2022-06-08Original Equipment
jG0Ji8N7hhYW8L+whRf4+Q==2022-06-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
699.2-715.8 MHz0.1850.006ppm58K6G7D27
699.2-715.8 MHz0.1830.006ppm181KG7D27
777.2-786.8 MHz0.1630.005ppm57K7G7D27
777.2-786.8 MHz0.1610.005ppm182KG7D27
1710.2-1754.8 MHz0.3960.002ppm60K8G7D27
1710.2-1754.8 MHz0.430.002ppm183KG7D27
1850.2-1909.8 MHz0.410.002ppm52K3G7D24E
1850.2-1909.8 MHz0.4290.002ppm181KG7D24E
2402-2480 MHz0.002000015C

Grants

TCB Grant - Application rZZoeqcaSTGKwtxsZDZHEg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  North American EMC Certification Services Inc
24889 Ferguson Ave
Maple Ridge, BC,
Canada
Date of Grant: 06/08/2022

Application Dated: 06/08/2022
Sensolus NV
Rijsenbergstraat 148 D
Gent, 9000
Belgium
 
Attention: Koen Van Vlaenderen , HW Lead / Co-Fouder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQYP-TRACK1100
Name of Grantee:  Sensolus NV
Equipment Class: Digital Transmission System
Notes: TRACK1100
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  

Power listed is maximum conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application rZZoeqcaSTGKwtxsZDZHEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensolus NV
Rijsenbergstraat 148 D
Gent, 9000
Belgium
  Date of Grant: 06/08/2022

Application Dated: 06/08/2022
 
Attention: Koen Van Vlaenderen , HW Lead / Co-Fouder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQYP-TRACK1100
Name of Grantee:  Sensolus NV
Equipment Class: Digital Transmission System
Notes: TRACK1100
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  

Power listed is maximum conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application jG0Ji8N7hhYW8L+whRf4+Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  North American EMC Certification Services Inc
24889 Ferguson Ave
Maple Ridge, BC,
Canada
Date of Grant: 06/08/2022

Application Dated: 06/08/2022
Sensolus NV
Rijsenbergstraat 148 D
Gent, 9000
Belgium
 
Attention: Koen Van Vlaenderen , HW Lead / Co-Fouder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQYP-TRACK1100
Name of Grantee:  Sensolus NV
Equipment Class: PCS Licensed Transmitter
Notes: TRACK1100
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.41 0.002  PM 52K3G7D
24E 1850.2  -  1909.8 0.429 0.002  PM 181KG7D
27 1710.2  -  1754.8 0.396 0.002  PM 60K8G7D
27 1710.2  -  1754.8 0.43 0.002  PM 183KG7D
27 699.2  -  715.8 0.185 0.006  PM 58K6G7D
27 699.2  -  715.8 0.183 0.006  PM 181KG7D
27 777.2  -  786.8 0.163 0.005  PM 57K7G7D
27 777.2  -  786.8 0.161 0.005  PM 182KG7D

Power listed is maximum EIRP/ERP for above and below 1 GHz respectively. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

This device supports NB-IoT Bands 2, 4, 12, and 13 with sub-carrier spacings of 3.75 kHz & 15 kHz.


EAS Grant - Application jG0Ji8N7hhYW8L+whRf4+Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensolus NV
Rijsenbergstraat 148 D
Gent, 9000
Belgium
  Date of Grant: 06/08/2022

Application Dated: 06/08/2022
 
Attention: Koen Van Vlaenderen , HW Lead / Co-Fouder

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQYP-TRACK1100
Name of Grantee:  Sensolus NV
Equipment Class: PCS Licensed Transmitter
Notes: TRACK1100
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.41 0.002  PM 52K3G7D
24E 1850.2  -  1909.8 0.429 0.002  PM 181KG7D
27 1710.2  -  1754.8 0.396 0.002  PM 60K8G7D
27 1710.2  -  1754.8 0.43 0.002  PM 183KG7D
27 699.2  -  715.8 0.185 0.006  PM 58K6G7D
27 699.2  -  715.8 0.183 0.006  PM 181KG7D
27 777.2  -  786.8 0.163 0.005  PM 57K7G7D
27 777.2  -  786.8 0.161 0.005  PM 182KG7D

Power listed is maximum EIRP/ERP for above and below 1 GHz respectively. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

This device supports NB-IoT Bands 2, 4, 12, and 13 with sub-carrier spacings of 3.75 kHz & 15 kHz.



Mail To: