FCC ID 2AR2V-PDA-5501
Intelligent Handheld Terminal
by CLINICAL LABORATORY TECHNOLOGY
Grantee Code: 2AR2V Product Code: PDA5501
Latest application date: 2019-01-21
FCC ID Device Details
| FCC ID | 2AR2V-PDA-5501 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AR2V |
| Product Code | PDA5501 |
| Applicant Business | CLINICAL LABORATORY TECHNOLOGY 🇨🇴 |
| Related Domains | |
| Equipment Class | Intelligent Handheld Terminal |
| Test Firm | Waltek Testing Group (Shenzhen) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 826.4-846.6 MHz | Original Equipment | 2019-01-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-01-21 | PDF 305.4 KB |
| Internal photos | Internal Photos | 2019-01-21 | PDF 520.7 KB |
| External photos | External Photos | 2019-01-21 | PDF 219.4 KB |
| Label and location | ID Label/Location Info | 2019-01-21 | PDF 62.8 KB |
| RF Test set-up photo | Test Setup Photos | 2019-01-21 | PDF 619.5 KB |
| RF Test Report -LTE | Test Report | 2019-01-21 | PDF 356.2 KB |
| RF Test Report-Appendix LTE B2-1 | Test Report | 2019-01-21 | PDF 4.8 MB |
| RF Test Report-Appendix LTE B2-2 | Test Report | 2019-01-21 | PDF 3.2 MB |
| RF Test Report-Appendix LTE B2-3 | Test Report | 2019-01-21 | PDF 2.9 MB |
| RF Test Report-Appendix LTE B2-4 | Test Report | 2019-01-21 | PDF 5.4 MB |
| RF Test Report-Appendix LTE B2-5 | Test Report | 2019-01-21 | PDF 4 MB |
| RF Test Report-Appendix LTE B2-6 | Test Report | 2019-01-21 | PDF 4.4 MB |
| RF Test Report-Appendix LTE B2-7 | Test Report | 2019-01-21 | PDF 5.7 MB |
| RF Test Report-Appendix LTE B7-1 | Test Report | 2019-01-21 | PDF 4.8 MB |
| RF Test Report-Appendix LTE B7-2 | Test Report | 2019-01-21 | PDF 4.7 MB |
| RF Test Report-Appendix LTE B7-3 | Test Report | 2019-01-21 | PDF 5.6 MB |
| RF Test Report-Appendix LTE B7-4 | Test Report | 2019-01-21 | PDF 5.1 MB |
| RF Test Report-Appendix LTE B7-5 | Test Report | 2019-01-21 | PDF 4.7 MB |
| RF Test Report-Appendix LTE B7-6 | Test Report | 2019-01-21 | PDF 4.9 MB |
| RF Test Report-Appendix LTE B7-7 | Test Report | 2019-01-21 | PDF 3.8 MB |
| RF Test Report-Appendix LTE B7-8 | Test Report | 2019-01-21 | PDF 2.1 MB |
| RF Test Report-WCDMA | Test Report | 2019-01-21 | PDF 849.8 KB |
| SAR Test Report | RF Exposure Info | 2019-01-21 | PDF 1.9 MB |
| SAR Test Report-Appendix | RF Exposure Info | 2019-01-21 | PDF 1.3 MB |
| Authorization Letter | Cover Letter(s) | 2019-01-21 | PDF 33.7 KB |
| Family model letter | Cover Letter(s) | 2019-01-21 | PDF 12.2 KB |
| LTC Letter | Cover Letter(s) | 2019-01-21 | PDF 20.6 KB |
| LTE Band description letter | Cover Letter(s) | 2019-01-21 | PDF 42.6 KB |
| Block Diagram Metadata only | Block Diagram | PDF 557.1 KB | |
| Schematics-1 Metadata only | Schematics | PDF 4.3 MB | |
| Schematics-2 Metadata only | Schematics | PDF 4 MB | |
| Schematics-3 Metadata only | Schematics | PDF 4.5 MB | |
| Schematics-4 Metadata only | Schematics | PDF 3.6 MB | |
| Schematics-5 Metadata only | Schematics | PDF 2.6 MB | |
| Schematics-6 Metadata only | Schematics | PDF 3.2 MB | |
| Operational Description Metadata only | Operational Description | PDF 147.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 125.7 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 38 KB |
Application Information
| Application ID | mSYAogHzQ9NGKs6mbSV3dQ== |
|---|---|
| Final Action Date | 2019-01-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028068286 |
| Model | PDA-5501 |
| Frequency Range | 826.4-846.6 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Intelligent Handheld Terminal |
| Responsible Party | Carlos Gomez, manager, cgomez@cltech.net |
| Test Firm | Jandy So, Waltek Testing Group (Shenzhen) Co., Ltd., jandyso@semtest.com.cn |
| TCB Email | tcb@siemic.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is ERP for Part 22 and EIRP for Part 24. 27. Highest reported SAR for Body, Extremity are: 0.45 W/kg, 0.62 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| mSYAogHzQ9NGKs6mbSV3dQ== | 2019-01-21 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 826.4-846.6 MHz | 0.0859 | 0.197ppm | 4M92F9W | 22H |
| 1850.7-1909.3 MHz | 0.13366 | 0.003ppm | 4M85G7D | 24E |
| 1850.7-1909.3 MHz | 0.13335 | 0.003ppm | 9M45G7D | 24E |
| 1850.7-1909.3 MHz | 0.13964 | 0.003ppm | 9M51W7D | 24E |
| 1852.4-1907.6 MHz | 0.11535 | 0.09ppm | 4M95F9W | 24E |
| 2500-2570 MHz | 0.14223 | 0.002ppm | 18M8G7D | 27 |
| 2500-2570 MHz | 0.12942 | 0.002ppm | 9M54W7D | 27 |
| 2500-2570 MHz | 0.12417 | 0.002ppm | 18M7W7D | 27 |
Grants
TCB Grant - Application mSYAogHzQ9NGKs6mbSV3dQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bureau Veritas Consumer Products Services, Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 01/21/2019 Application Dated: 01/20/2019 |
| CLINICAL LABORATORY TECHNOLOGY |
| Street 26 # 59 51 Office 201 Building Argos |
| Bogota, Colombia |
| Attention: Carlos Gomez , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AR2V-PDA-5501 |
| Name of Grantee: | CLINICAL LABORATORY TECHNOLOGY |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Intelligent Handheld Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.0859 | 0.197 PM | 4M92F9W | |
| 24E | 1852.4 - 1907.6 | 0.11535 | 0.09 PM | 4M95F9W | |
| 24E | 1850.7 - 1909.3 | 0.13366 | 0.003 PM | 4M85G7D | |
| 24E | 1850.7 - 1909.3 | 0.13335 | 0.003 PM | 9M45G7D | |
| 24E | 1850.7 - 1909.3 | 0.13964 | 0.003 PM | 9M51W7D | |
| 27 | 2500.0 - 2570.0 | 0.14223 | 0.002 PM | 18M8G7D | |
| 27 | 2500.0 - 2570.0 | 0.12942 | 0.002 PM | 9M54W7D | |
| 27 | 2500.0 - 2570.0 | 0.12417 | 0.002 PM | 18M7W7D |
| Output power listed is ERP for Part 22 and EIRP for Part 24. 27. Highest reported SAR for Body, Extremity are: 0.45 W/kg, 0.62 W/kg. |
EAS Grant - Application mSYAogHzQ9NGKs6mbSV3dQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
CLINICAL LABORATORY TECHNOLOGY Street 26 # 59 51 Office 201 Building Argos Bogota, Colombia |
Date of Grant: 01/21/2019 Application Dated: 01/20/2019 |
| Attention: Carlos Gomez , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AR2V-PDA-5501 |
| Name of Grantee: | CLINICAL LABORATORY TECHNOLOGY |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Intelligent Handheld Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.0859 | 0.197 PM | 4M92F9W | |
| 24E | 1852.4 - 1907.6 | 0.11535 | 0.09 PM | 4M95F9W | |
| 24E | 1850.7 - 1909.3 | 0.13366 | 0.003 PM | 4M85G7D | |
| 24E | 1850.7 - 1909.3 | 0.13335 | 0.003 PM | 9M45G7D | |
| 24E | 1850.7 - 1909.3 | 0.13964 | 0.003 PM | 9M51W7D | |
| 27 | 2500.0 - 2570.0 | 0.14223 | 0.002 PM | 18M8G7D | |
| 27 | 2500.0 - 2570.0 | 0.12942 | 0.002 PM | 9M54W7D | |
| 27 | 2500.0 - 2570.0 | 0.12417 | 0.002 PM | 18M7W7D |
| Output power listed is ERP for Part 22 and EIRP for Part 24. 27. Highest reported SAR for Body, Extremity are: 0.45 W/kg, 0.62 W/kg. |
| Mail To: |