W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.

Hyco Genyong Technology Co., Ltd. Smart Watch ( with BT,WIFI)

Page 1 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 2 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 3 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 4 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 5 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 6 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 7 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 8 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Page 9 of W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.

REPORT No.:SZ18100034S01
Annex C Plots of System Performance Check
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.10.18
System Check_2450MHz_Head_181018
Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: HSL_2450_181018 Medium parameters used: f = 2450 MHz; σ = 1.86 S/m; εr = 40.045; ρ
= 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: ES3DV3 - SN3154; ConvF(4.61, 4.61, 4.61); Calibrated: 2017.10.30;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW2450/Area Scan (71x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 15.6 W/kg
CW2450/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 89.51 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 30.1 W/kg
SAR(1 g) = 13.13 W/kg; SAR(10 g) = 6.16 W/kg
Maximum value of SAR (measured) = 14.8 W/kg
0 dB = 15.7 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5200MHz_Head_181115
DUT: Dipole 5GHz
Communication System: UID 0, CW (0); Frequency: 5200 MHz;Duty Cycle: 1:1
Medium: HSL_5200_181115 Medium parameters used: f = 5200 MHz; σ = 4.695 S/m; εr = 37.042; ρ
= 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(5.28, 5.28, 5.28); Calibrated: 2018.11.12;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5200/Area Scan (201x201x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 8.39 W/kg
CW5200/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=4mm
Reference Value = 34.81 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 45.7 W/kg
SAR(1 g) = 8.16 W/kg; SAR(10 g) = 2.22 W/kg
Maximum value of SAR (measured) = 8.00 W/kg
0 dB = 8.39 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5300MHz_Head_181115
DUT: Dipole 5GHz
Communication System: UID 0, CW (0); Frequency: 5300 MHz;Duty Cycle: 1:1
Medium: HSL_5300_181115 Medium parameters used: f = 5300 MHz; σ = 4.817 S/m; εr = 36.838; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(5.28, 5.28, 5.28); Calibrated: 2018.11.12;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5300/Area Scan (201x201x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 8.05 W/kg
CW5300/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 35.74 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 35.4 W/kg
SAR(1 g) = 7.83 W/kg; SAR(10 g) = 2.26 W/kg
Maximum value of SAR (measured) = 16.1 W/kg
0 dB = 8.05 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5800MHz_Head_181115
DUT: Dipole 5GHz
Communication System: UID 0, CW (0); Frequency: 5800 MHz;Duty Cycle: 1:1
Medium: HSL_5800_181115 Medium parameters used: f = 5800 MHz; σ = 5.432 S/m; εr = 35.732; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(4.60, 4.60, 4.60); Calibrated: 2018.11.12;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5800/Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 16.6 W/kg
CW5800/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 34.60 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 44.2 W/kg
SAR(1 g) = 8.13 W/kg; SAR(10 g) = 2.25 W/kg
Maximum value of SAR (measured) = 17.5 W/kg
0 dB = 16.6 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.10.18
System Check_2450MHz_Body_181018
Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450_181018 Medium parameters used: f = 2450 MHz; σ = 2.039 S/m; εr = 50.603; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: ES3DV3 - SN3154; ConvF(4.28, 4.28, 4.28); Calibrated: 2017.10.30;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW 2450/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 15.6 W/kg
CW 2450/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 87.40 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 28.3 W/kg
SAR(1 g) = 13.4 W/kg; SAR(10 g) = 6.15 W/kg
Maximum value of SAR (measured) = 15.3 W/kg
0 dB = 15.3 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5200MHz_Body_181115
Communication System: UID 0, CW (0); Frequency: 5200 MHz;Duty Cycle: 1:1
Medium: MSL_5200_181115 Medium parameters used: f = 5200 MHz; σ = 5.364 S/m; εr = 48.458; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(4.73, 4.73, 4.73); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5200/Area Scan (201x201x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 9.05 W/kg
CW5200/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=4mm
Reference Value = 36.95 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 43.9 W/kg
SAR(1 g) = 7.61 W/kg; SAR(10 g) = 2.20 W/kg
Maximum value of SAR (measured) = 14.91 W/kg
0 dB = 14.91W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5300MHz_Body_181115
Communication System: UID 0, CW (0); Frequency: 5300 MHz;Duty Cycle: 1:1
Medium: MSL_5300_181115 Medium parameters used: f = 5300 MHz; σ = 5.503 S/m; εr = 48.195; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(4.73, 4.73, 4.73); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5300/Area Scan (201x201x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 8.5 W/kg
CW5300/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 38.52 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 42.2 W/kg
SAR(1 g) = 7.74 W/kg; SAR(10 g) = 2.21 W/kg
Maximum value of SAR (measured) = 18.5 W/kg
0 dB = 18.5 W/kg
Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.
Date: 2018.11.15
System Check_5800MHz_Body_181115
Communication System: UID 0, CW (0); Frequency: 5800 MHz;Duty Cycle: 1:1
Medium: MSL_5800_181115 Medium parameters used: f = 5800 MHz; σ = 6.182 S/m; εr = 47.417; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:21.1 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(3.98, 3.98, 3.98); Calibrated: 2018.11.12;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1516; Calibrated: 2018.07.14
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
CW5800/Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of Total (interpolated) = 8.60 W/kg
CW5800/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 37.03 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 48.6 W/kg
SAR(1 g) = 7.81 W/kg; SAR(10 g) = 2.22 W/kg
Maximum value of SAR (measured) = 18.3 W/kg
0 dB = 18.30 V/m
Download: W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Mirror Download [FCC.gov]W562 Smart Watch ( with BT,WIFI) RF Exposure Info RF_Annex C Plots of System Performance Check Hyco Genyong Technology Co., Ltd.
Document ID4114580
Application IDGaFhMNlI4XYPjxBhOmy5MA==
Document DescriptionRF_Annex C Plots of System Performance Check
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize102.34kB (1279263 bits)
Date Submitted2018-12-23 00:00:00
Date Available2018-12-24 00:00:00
Creation Date2018-11-06 15:53:56
Producing SoftwareAcrobat Distiller 9.3.2 (Windows)
Document Lastmod2018-12-11 14:06:39
Document TitleRF_Annex C Plots of System Performance Check
Document CreatorPScript5.dll Version 5.2.2

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : 
Create Date                     : 2018:11:06 15:53:56+08:00
Creator                         : PScript5.dll Version 5.2.2
Modify Date                     : 2018:12:11 14:06:39+08:00
Title                           : 
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2018:12:11 14:06:39+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Document ID                     : uuid:fdc60389-c96b-4568-896a-dc0f3fb2ac94
Instance ID                     : uuid:52a35d34-6435-4f55-bd7c-759a802c33a1
Producer                        : Acrobat Distiller 9.3.2 (Windows)
Page Count                      : 9