FCC ID 2ARMB-KO-202G
Smart GSM alarm host (main unit)
by Guangzhou Xinyang Electronic Technology Co. LTD
Grantee Code: 2ARMB Product Code: KO202G
Latest application date: 2019-05-29
FCC ID Device Details
| FCC ID | 2ARMB-KO-202G |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ARMB |
| Product Code | KO202G |
| Applicant Business | Guangzhou Xinyang Electronic Technology Co. LTD 🇨🇳 |
| Equipment Class | Smart GSM alarm host (main unit) |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2019-05-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2019-05-29 | PDF 408.6 KB |
| Internal photos | Internal Photos | 2019-05-29 | PDF 881.1 KB |
| External photos | External Photos | 2019-05-29 | PDF 463.3 KB |
| Label and label location | ID Label/Location Info | 2019-05-29 | PDF 128.7 KB |
| Letter of declaration label location | Cover Letter(s) | 2019-05-29 | PDF 116.7 KB |
| Test setup photos | Test Setup Photos | 2019-05-29 | PDF 210.2 KB |
| Test Report GSM | Test Report | 2019-05-29 | PDF 2 MB |
| Confidentiality request letter | Cover Letter(s) | 2019-05-29 | PDF 31.6 KB |
| RF exposure evaluation | RF Exposure Info | 2019-05-29 | PDF 216.4 KB |
| Block diagram Metadata only | Block Diagram | PDF 353.1 KB | |
| Schematic Metadata only | Schematics | PDF 331.7 KB | |
| Operation description Metadata only | Operational Description | PDF 78.2 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 51 KB |
Application Information
| Application ID | XiCm9BxYWMYtpBJY6DRhvg== |
|---|---|
| Final Action Date | 2019-05-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027951326 |
| Model | KO-202G |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Smart GSM alarm host (main unit) |
| Responsible Party | Meiying Chi, Manager, 2355708990@qq.com |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | tcb-essen@cetecom.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is ERP for Part 22H and EIRP for Part 24E. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. Integrators and End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| XiCm9BxYWMYtpBJY6DRhvg== | 2019-05-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application XiCm9BxYWMYtpBJY6DRhvg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CETECOM GmbH Im Teelbruch 116 45219 Essen, Germany |
Date of Grant: 05/29/2019 Application Dated: 05/29/2019 |
| Guangzhou Xinyang Electronic Technology Co. LTD |
| Room 3505, No. 5 Fuchang Road, Haizhu District |
| Guangzhou, 510000 China |
| Attention: Meiying Chi , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ARMB-KO-202G |
| Name of Grantee: | Guangzhou Xinyang Electronic Technology Co. LTD |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Smart GSM alarm host (main unit) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 0.9376 | 0.024 PM | 250KGXW | |
| 24E | 1850.2 - 1909.8 | 0.5929 | 0.006 PM | 248KGXW |
| Output power is ERP for Part 22H and EIRP for Part 24E. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. Integrators and End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application XiCm9BxYWMYtpBJY6DRhvg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Guangzhou Xinyang Electronic Technology Co. LTD Room 3505, No. 5 Fuchang Road, Haizhu District Guangzhou, 510000 China |
Date of Grant: 05/29/2019 Application Dated: 05/29/2019 |
| Attention: Meiying Chi , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ARMB-KO-202G |
| Name of Grantee: | Guangzhou Xinyang Electronic Technology Co. LTD |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Smart GSM alarm host (main unit) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 0.9376 | 0.024 PM | 250KGXW | |
| 24E | 1850.2 - 1909.8 | 0.5929 | 0.006 PM | 248KGXW |
| Output power is ERP for Part 22H and EIRP for Part 24E. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. Integrators and End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |