FCC ID 2ARRW-AO00059
Lora Remote Control RF Link AO00059
by Airobotics Inc.
Grantee Code: 2ARRW Product Code: AO00059
Latest application date: 2019-01-30
FCC ID Device Details
| FCC ID | 2ARRW-AO00059 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ARRW |
| Product Code | AO00059 |
| Applicant Business | Airobotics Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Lora Remote Control RF Link AO00059 |
| Test Firm | ITL PRODUCT TESTING LTD |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 903-927 MHz | Original Equipment | 2019-01-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-01-30 | PDF 1.4 MB |
| Int Photo | Internal Photos | 2019-01-30 | PDF 1.4 MB |
| External Photo | External Photos | 2019-01-30 | PDF 1.4 MB |
| Label Loc | ID Label/Location Info | 2019-01-30 | PDF 195.1 KB |
| Label Smpl | ID Label/Location Info | 2019-01-30 | PDF 461.9 KB |
| Test Setup Photos | Test Setup Photos | 2019-01-30 | PDF 1.1 MB |
| Test Report | Test Report | 2019-01-30 | PDF 2.7 MB |
| Authorization-Letter | Cover Letter(s) | 2019-01-30 | PDF 91.5 KB |
| Confidentiality-Request-Letter | Cover Letter(s) | 2019-01-30 | PDF 149 KB |
| Form-731-Signature-Authorization-Letter | Cover Letter(s) | 2019-01-30 | PDF 93.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 102.1 KB | |
| Schematics Metadata only | Schematics | PDF 1.7 MB | |
| Operational Description Metadata only | Operational Description | PDF 202.8 KB | |
| Part List Metadata only | Parts List/Tune Up Info | PDF 35 KB |
Application Information
| Application ID | s58X/0crnRTyKpNfVg4ppw== |
|---|---|
| Final Action Date | 2019-01-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027371491 |
| Model | AO00059 |
| Frequency Range | 903-927 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Lora Remote Control RF Link AO00059 |
| Responsible Party | Issac Sela, isela@airoboticsdrones.com |
| Test Firm | Ilan Cohen, ITL PRODUCT TESTING LTD, icohen@itl.co.il |
| TCB Email | tei@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power listed is the maximum conducted output power. This device must be installed to provide a separation distance of at least 6 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| s58X/0crnRTyKpNfVg4ppw== | 2019-01-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 903-927 MHz | 0.1120000 | 15C |
Grants
TCB Grant - Application s58X/0crnRTyKpNfVg4ppw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 01/30/2019 Application Dated: 01/30/2019 |
| Airobotics Inc. |
| 8340 E Raintree Dr. Building E |
| Scottsdale, AZ 85260 |
| Attention: Issac Sela |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ARRW-AO00059 |
| Name of Grantee: | Airobotics Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Lora Remote Control RF Link AO00059 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 903.0 - 927.0 | 0.112 |
| Output Power listed is the maximum conducted output power. This device must be installed to provide a separation distance of at least 6 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. |
EAS Grant - Application s58X/0crnRTyKpNfVg4ppw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Airobotics Inc. 8340 E Raintree Dr. Building E Scottsdale, AZ 85260 United States |
Date of Grant: 01/30/2019 Application Dated: 01/30/2019 |
| Attention: Issac Sela |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ARRW-AO00059 |
| Name of Grantee: | Airobotics Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Lora Remote Control RF Link AO00059 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 903.0 - 927.0 | 0.112 |
| Output Power listed is the maximum conducted output power. This device must be installed to provide a separation distance of at least 6 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. |
| Mail To: |