AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD

AUTOSLIDE PTY LTD Pedestrian AUTOSLIDE Sliding Door Operator

Page 1 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 2 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 3 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 4 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 5 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 6 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 7 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 8 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 9 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 10 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 11 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 12 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 13 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 14 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 15 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 16 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 17 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 18 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 19 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 20 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 21 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 22 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 23 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Page 24 of AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD

FCC Part15 Subpart B
TEST REPORT
For
Pedestrian AUTOSLIDE Sliding Door Operator
MODEL NUMBER: AUTOSLIDE AS5
REPORT NUMBER: 4788771104.1.2
ISSUE DATE: Dec 18, 2018
FCC ID No.: 2ARVQ-AS5
Prepared for
AUTOSLIDE PTY LTD
Unit 3/413, Wetherill Park, 2164 NSW, Australia
Prepared by
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
Room 101, Building 10, Innovation Technology Park, Song Shan Lake Hi tech
Development Zone, Dongguan, 523808, China
Tel: +86 769 33817100
Fax: +86 769 33244054
Website: www.ul.com
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other
similar products. This report does not imply that the product(s) has met the criteria for certification.
REPORT NO.: 4788771104.1.2
Page 2 of 24
Revision History
Rev.
Issue Date
Revisions
--
12/18/2018
Initial Issue
Revised By
--
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 3 of 24
Summary of Test Results
Standard
FCC Part15, Subpart B
ANSI C63.4-2014
Test Item
Limit
Result
Conducted Disturbance
Class B
PASS
Radiated Disturbance below 1 GHz
Class B
PASS
Radiated Disturbance above 1 GHz
Class B
PASS
Remark
NOTE (1)
NOTE (2)
Note:
(1) “N/A” denotes test is not applicable in this Test Report
(2) If the highest frequency of the internal sources of the EUT is less than 108 MHz, the
measurement shall only be made up to 1 GHz. If the highest frequency of the internal sources of
the EUT is between 108 MHz and 500 MHz, the measurement shall only be made up to 2 GHz. If
the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz,
measurement shall only be made up to 5 GHz. If the highest frequency of the internal sources of
the EUT is above 1 GHz, the measurement shall be made up to 5 times the highest frequency or
40 GHz, whichever is less.
The highest internal frequency is 433MHz.
This report does not include a test of the intentional part.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 4 of 24
CONTENTS
1.
ATTESTATION OF TEST RESULTS ..................................................................................... 5
2.
TEST METHODOLOGY......................................................................................................... 6
3.
FACILITIES AND ACCREDITATION..................................................................................... 6
4.
CALIBRATION AND UNCERTAINTY ................................................................................... 7
5.
4.1.
Measuring Instrument Calibration ............................................................................. 7
4.2.
Measurement Uncertainty ......................................................................................... 7
EQUIPMENT UNDER TEST .................................................................................................. 8
5.1.
Description of EUT .................................................................................................... 8
5.2.
Test Mode ................................................................................................................ 8
5.3.
EUT Accessory ......................................................................................................... 8
5.4.
Block Diagram Showing the Configuration of System Tested .................................... 9
6.
MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 10
7.
EMISSION TEST ................................................................................................................. 11
7.1.
7.1.1.
7.1.2.
7.1.3.
7.1.4.
7.1.5.
7.1.6.
Conducted Disturbance Measurement .................................................................... 11
Limits of conducted disturbance voltage ................................................................. 11
Test Procedure ....................................................................................................... 11
Test Setup .............................................................................................................. 12
Test Environment .................................................................................................... 12
Test Mode ............................................................................................................... 12
Test Results ............................................................................................................ 13
7.2.
7.2.1.
7.2.2.
7.2.3.
7.2.4.
7.2.5.
7.2.6.
7.2.7.
Radiated Disturbance Measurement ....................................................................... 15
Limits of radiated disturbance measurement ........................................................... 15
Test Procedure ....................................................................................................... 16
Test Setup .............................................................................................................. 16
Test Environment .................................................................................................... 17
Test Mode ............................................................................................................... 17
Test Results – below 1GHz ..................................................................................... 18
Test Results – Above 1GHz .................................................................................... 20
Appendix I: Photographs of EMC Test Configuration ............................................................ 22
Appendix II: Photographs of the EUT ...................................................................................... 24
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 5 of 24
1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:
Address:
Manufacturer Information
Company Name:
Address:
Factory Information
Company Name:
Address:
EUT Information
EUT Name:
Model:
Brand:
Sample Status:
Sample ID:
Sample Received Date:
Date of Tested:
AUTOSLIDE PTY LTD
Unit 3/413, Wetherill Park, 2164 NSW, Australia
Same as the applicant
Same as the applicant
Qingdao Autoslide Smart Door System Co. Ltd
No.26, Xianshan Dong Road, Chengyang District, Qingdao
Qingdao 266107,China
Pedestrian AUTOSLIDE Sliding Door Operator
AUTOSLIDE AS5
Autoslide
Normal
#1
Dec 07, 2018
Dec 07, 2018 ~ Dec 14, 2018
APPLICABLE STANDARDS
STANDARDS
TEST RESULTS
FCC Part15, Subpart B
ANSI C63.4-2014
PASS
Tested By:
Checked By:
Chris Chen
Engineer Project Associate
Approved By:
Shawn Wen
Laboratory Leader
Stephen Guo
Laboratory Manager
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 6 of 24
2. TEST METHODOLOGY
All tests were performed in accordance with the standard FCC Part15 Subpart B and ANSI
C63.4-2014.
3. FACILITIES AND ACCREDITATION
Accreditation
Certificate
A2LA (Certificate No.: 4338.01)
Shenzhen STS Test Services Co., Ltd.
has been assessed and proved to be in compliance with A2LA.
CNAS (Registration No.: L7649)
Shenzhen STS Test Services Co., Ltd.
has been assessed and proved to be in compliance with CNAS.
FCC (FCC Designation No.: 625569)
Shenzhen STS Test Services Co., Ltd.
has been recognized to perform compliance testing on equipment subject to
the Commission's Declaration of Conformity (DoC) and Certification rules
IC (Company No.: 12108A)
Shenzhen STS Test Services Co., Ltd.
has been registered and fully described in a report filed with Industry
Canada. The Company Number is 12108A.
Note: All tests measurement facilities use to collect the measurement data are located at
1/F., Building B, Zhuoke Science Park, No.190, Chongqing Road, Fuyong Street, Bao’an District,
Shenzhen, Guangdong, China
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 7 of 24
4. CALIBRATION AND UNCERTAINTY
4.1. Measuring Instrument Calibration
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.
4.2. Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:
Test Item
Conducted disturbance at mains
terminals ports
Radiated disturbance Test
Measurement Frequency
Range
U(dB)
0.15MHz ~ 30MHz
2.67 dB
Below 1GHz
3.92 dB
Radiated disturbance Test
Above 1GHz
3.31 dB
Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 8 of 24
5. EQUIPMENT UNDER TEST
5.1. Description of EUT
EUT Name
Pedestrian AUTOSLIDE Sliding Door Operator
EUT Description
Model
The device is an Electronic Sliding Door Operator with RF receiver
AUTOSLIDE AS5
Series Model
--
Model Difference
--
Rated Input
AC 120V 60Hz
Power Supply
AC 120V 60Hz
5.2. Test Mode
Test Mode
Mode 1
Description
Normal Working .
5.3. EUT Accessory
Item
Accessory
Brand Name
Model Name
Description
--
--
--
--
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 9 of 24
5.4. Block Diagram Showing the Configuration of System Tested
AC
EUT
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Mfr/Brand
Model/Type No.
Specification
Series No.
--
--
--
--
--
--
Item
Type of cable
Shielded Type
Ferrite Core
Length
--
--
--
--
--
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 10 of 24
6. MEASURING EQUIPMENT AND SOFTWARE USED
Conducted Emissions
Used
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Next Cal.

Test Receiver
R&S
ESCI
101427
2018.10.15
2019.10.14

LISN
R&S
ENV216
101242
2018.10.15
2019.10.14

Conduction Cable
EM
C01
N/A
2018.10.18
2019.10.17

Temperature & Humidity
Mieo
HH660
N/A
2018.10.15
2019.10.14
Radiated Emissions
Used
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Next Cal.

EMI Test Receiver
R&S
ESW
101535
2018.06.01
2019.05.31

Bilog Antenna
TESEQ
CBL6111D
34678
2018.10.30
2019.10.29

Horn Antenna
Schwarzbeck
BBHA 9120D
9120D-1343
2018.10.27
2019.10.26

SHF-EHF Horn Antenna
(15G-40GHz)
BBHA 9170
SCHWARZBECK
BBHA917036
2018.05.02
2019.05.01

Temperature & Humidity
HH660
Mieo
N/A
2018.10.15
2019.10.14

Temperature & Humidity
HH660
Mieo
N/A
2018.10.15
2019.10.14

Pre-Amplifier
(0.1M-3GHz)
Pre Amplifier (1G26.5GHz)
Operational Manual
Passive Loop (9K--30MHz)
EM
EM330
60538
2018.10.28
2019.10.27
Agilent
8449B
60538
2018.10.15
2019.10.14
ETS
6512
00165355
2018.10.18
2019.10.17

Low Frequency Cable
EM
R01
N/A
2018.10.18
2019.10.17

Low Frequency Cable
EM
R06
N/A
2018.10.18
2019.10.17

High Frequency Cable
SCHWARZBECK
R04
N/A
2018.10.18
2019.10.17

High Frequency Cable
SCHWARZBECK
R02
N/A
2018.10.18
2019.10.17

Semi-anechoic Chamber
Changling
966
N/A
2018.10.15
2019.10.14

Turn Table
EM
SC100_1
60531
N/A
N/A

Antenna Mast
EM
SC100
N/A
N/A
N/A

Max-full Antenna Corp
MF
MFA-440H
N/A
N/A
N/A


UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 11 of 24
7. EMISSION TEST
7.1. Conducted Disturbance Measurement
7.1.1.
Limits of conducted disturbance voltage
Class A (dBμV)
Class B (dBμV)
FREQUENCY
(MHz)
Quasi-peak
Average
Quasi-peak
Average
0.15 -0.5
79.00
66.00
66 - 56 *
56 - 46 *
0.50 -5.0
73.00
60.00
56.00
46.00
5.0 -30.0
73.00
60.00
60.00
50.00
Note:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the
logarithm of the frequency in the range.
(3) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor
Margin Level = Measurement Value - Limit Value
The following table is the setting of the receiver
Receiver Parameters
Attenuation
Start Frequency
Stop Frequency
IF Bandwidth
7.1.2.
Setting
10 dB
0.15 MHz
30 MHz
9 kHz
Test Procedure
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being
connected to the power mains through a line impedance stabilization network (LISN). All
other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/
50uH of coupling impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end
of the cable may be terminated, if required, using the correct terminating impedance. The
overall length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item:EUT Test Photos.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 12 of 24
7.1.3.
Test Setup
Receiver
40cm
EUT
80cm
AMN
80/10
cm
For the actual test configuration, please refer to Appendix I: Photographs of the Test
Configuration.
7.1.4.
Test Environment
Temperature:
25.2℃
Humidity:
60%
ATM pressure:
101kPa
7.1.5.
Test Mode
Pre-test Mode:
Mode 1
Final Test Mode:
Mode 1
Note: According to pre-test results, the final test mode is each independent function's worst case
and only shown in the report.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 13 of 24
7.1.6.
Test Results
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Phase: Line
No.
Frequency
(MHz)
Reading
(dBuV)
Correct
Factor(dB)
Result
(dBuV)
Limit
(dBuV)
Margin
(dB)
Remark
10
11
12
0.1580
0.1580
0.4700
0.4700
0.7820
0.7820
1.0940
1.0940
4.5580
4.5580
23.6340
23.6340
28.54
15.05
24.95
22.78
23.55
21.90
22.97
21.59
16.65
9.60
17.72
13.44
20.23
20.23
20.48
20.48
20.23
20.23
20.15
20.15
19.95
19.95
19.51
19.51
48.77
35.28
45.43
43.26
43.78
42.13
43.12
41.74
36.60
29.55
37.23
32.95
65.57
55.57
56.51
46.51
56.00
46.00
56.00
46.00
56.00
46.00
60.00
50.00
-16.80
-20.29
-11.08
-3.25
-12.22
-3.87
-12.88
-4.26
-19.40
-16.45
-22.77
-17.05
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
Remark:
Result = Reading +Correct
Margin = Result - Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 14 of 24
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Phase: Neutral
No.
Frequency
(MHz)
Reading
(dBuV)
Correct
Factor(dB)
Result
(dBuV)
Limit
(dBuV)
Margin
(dB)
Remark
10
11
12
0.1580
0.1580
0.4380
0.4380
0.6260
0.6260
1.6860
1.6860
4.2460
4.2460
25.6620
25.6620
29.32
15.62
25.47
23.05
24.74
22.32
22.29
19.81
16.32
10.54
18.80
14.66
20.23
20.23
20.49
20.49
20.34
20.34
20.10
20.10
19.95
19.95
19.36
19.36
49.55
35.85
45.96
43.54
45.08
42.66
42.39
39.91
36.27
30.49
38.16
34.02
65.57
55.57
57.10
47.10
56.00
46.00
56.00
46.00
56.00
46.00
60.00
50.00
-16.02
-19.72
-11.14
-3.56
-10.92
-3.34
-13.61
-6.09
-19.73
-15.51
-21.84
-15.98
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
Remark:
Result = Reading +Correct
Margin = Result – Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 15 of 24
7.2. Radiated Disturbance Measurement
7.2.1.
Limits of radiated disturbance measurement
Below 1 GHz
Measurement Method and Applied Limits:
ANSI C63.4:
Class A
Frequency
Field strength
Field strength
(MHz)
(uV/m) ( at 10m)
(dBuV/m) (at 3m)
30 - 88
90
49.5
Class B
Field strength
(dBuV/m) (at 3m)
40
88 - 216
150
53.9
43.5
216 - 960
210
56.9
46
Above 960
300
60
54
Above 1 GHz
Measurement Method and Applied Limits:
ANSI C63.4:
Class A
Frequency
(dBuV/m) (at 3m)
(dBuV/m) (at 10m)
(MHz)
Peak
Average
Peak
Average
Above 1000
80
60
69.5
49.5
Class B
(dBuV/m) (at 3m)
Peak
Average
74
54
Frequency Range of Radiated Disturbance Measurement
Highest frequency generated or Upper
frequency of measurement used in the device
or on which the device operates or tunes
(MHz)
Below 1.705
1.705 - 108
108 - 500
500 - 1000
Above 1000
Range (MHz)
30
1000
2000
5000
5th harmonic of the highest frequency or
40 GHz, whichever is lower
NOTE:
(1) The limit for radiated test was performed according to FCC Part 15, Subpart B;
(2) The tighter limit applies at the band edges;
(3) Emission level (dBuV/m) = 20log Emission level (uV/m),
3m Emission level = 10m Emission level + 20log(10m/3m);
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor,
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use),
Margin Level = Measurement Value - Limit Value.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 16 of 24
7.2.2.
Test Procedure
a. The measuring distance of at 3m shall be used for measurements at frequency up to
1GHz.
b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3
meter chamber. The table was rotated 360 degrees to determine the position of the
highest radiation.
c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the
test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of
the antenna are set to make the measurement.
d. For the actual test configuration, please refer to the related Item:EUT Test Photos.
7.2.3.
Test Setup
(a) Radiated Disturbance Test Set-Up Frequency 30MHz - 1GHz
Cabinet
Semi Anechoic Chamber
Antenna Tower
Receiver
3m
360°
Position
Controller
1m~4m
EUT
Turntable
0.8/0.1m
Antenna
Preamplifier
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 17 of 24
(b) Radiated Disturbance Test Set-Up Frequency above 1GHz
Cabinet
Semi Anechoic Chamber
Antenna Mount
360°
Receiver
Position
Controller
1m~4m
3m
EUT
0.8/0.1m
Preamplifier
For the actual test configuration, please refer to Appendix I: Photographs of the Test
Configuration.
7.2.4.
Test Environment
Radiated Disturbance - below 1 GHz
Radiated Disturbance - above 1 GHz
Temperature:
25.3℃
Temperature:
N/A
Humidity:
51%
Humidity:
N/A
ATM pressure:
101kPa
ATM pressure:
N/A
7.2.5.
Test Mode
Radiated Disturbance - below 1 GHz
Radiated Disturbance - above 1 GHz
Pre-test Mode:
Mode 1
Pre-test Mode:
N/A
Final Test Mode:
Mode 1
Final Test Mode:
N/A
Note: According to pre-test results, the final test mode is each independent function's worst case
and only shown in the report.
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 18 of 24
7.2.6.
Test Results – below 1GHz
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Polarization: Vertical
No.
Frequency
(MHz)
Reading
(dBuV)
Correct
Factor(dB/m)
Result
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Remark
40.9881
60.9176
86.5030
152.1297
239.9873
890.7278
49.74
54.12
47.37
39.54
40.30
29.89
-16.84
-24.32
-21.07
-18.08
-17.76
-2.38
32.90
29.80
26.30
21.46
22.54
27.51
40.00
40.00
40.00
43.50
46.00
46.00
-7.10
-10.20
-13.70
-22.04
-23.46
-18.49
QP
QP
QP
QP
QP
QP
Remark:
Result = Reading +Correct
Margin = Result – Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 19 of 24
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Polarization: Horizontal
No.
Frequency
(MHz)
Reading
(dBuV)
Correct
Factor(dB/m)
Result
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Remark
40.1347
54.8348
133.1511
206.3976
633.9073
982.6200
40.04
48.84
45.11
47.09
28.94
28.18
-16.40
-22.86
-17.54
-19.89
-6.39
-0.14
23.64
25.98
27.57
27.20
22.55
28.04
40.00
40.00
43.50
43.50
46.00
54.00
-16.36
-14.02
-15.93
-16.30
-23.45
-25.96
QP
QP
QP
QP
QP
QP
Remark:
Result = Reading +Correct
Margin = Result – Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 20 of 24
7.2.8.
Test Results – Above 1GHz
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Polarization: Vertical
No.
1**
2**
3**
4**
5**
6**
Frequency
(MHz)
1968.000
1968.000
2412.000
2412.000
8170.000
8170.000
14356.000
14356.000
21856.000
21856.000
24304.001
24304.001
Results
(dBuV/m)
28.63
37.99
28.12
37.29
24.11
34.67
41.39
50.89
44.72
55.26
46.05
57.11
Factor (dB)
-0.55
-0.55
-1.23
-1.23
10.28
10.28
25.12
25.12
23.92
23.92
23.21
23.21
Limit
(dBuV/m)
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
Over Limit
(dB)
-25.37
-36.01
-25.88
-36.71
-29.89
-39.33
-12.61
-23.11
-9.28
-18.74
-7.95
-16.89
Detector
ANT
Verdict
AV
Peak
AV
Peak
AV
Peak
AV
Peak
AV
Peak
AV
Peak
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Remark:
Result = Reading +Correct
Margin = Result – Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 21 of 24
Test Mode:
Mode 1
Test Voltage:
AC 120V/60Hz
Model:
AUTOSLIDE AS5
Polarization: Horizontal
No.
1**
2**
3**
4**
5**
6**
Frequency
(MHz)
1932.000
1932.000
2414.000
2414.000
7990.000
7990.000
14368.000
14368.000
21376.000
21376.000
24352.000
24352.000
Results
(dBuV/m)
27.92
37.81
28.58
38.24
24.57
34.89
41.72
50.24
43.84
54.90
46.00
56.64
Factor (dB)
-0.95
-0.95
-1.25
-1.25
10.65
10.65
24.92
24.92
24.04
24.04
23.19
23.19
Limit
(dBuV/m)
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
54.0
74.0
Over Limit
(dB)
-26.08
-36.19
-25.42
-35.76
-29.43
-39.11
-12.28
-23.76
-10.16
-19.10
-8.00
-17.36
Detector
ANT
Verdict
AV
Peak
AV
Peak
AV
Peak
AV
Peak
AV
Peak
AV
Peak
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Remark:
Result = Reading +Correct
Margin = Result – Limit
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 22 of 24
Appendix I: Photographs of EMC Test Configuration
Conducted Disturbance
Radiated Disturbance Below 1 GHz
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 23 of 24
Radiated Disturbance Above 1 GHz
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
REPORT NO.: 4788771104.1.2
Page 24 of 24
Appendix II: Photographs of the EUT
Refer to appendix report No.:4788771104.1.2-A1 & 4788771104.1.2-A2
END OF REPORT
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
Co., Ltd, Song Shan Lake Branch.
Download: AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Mirror Download [FCC.gov]AS5 Pedestrian AUTOSLIDE Sliding Door Operator Test Report 1 AUTOSLIDE PTY LTD
Document ID4115186
Application ID93B7+zfGL1YjlMejtA89tQ==
Document DescriptionFCC Part 15B report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize70.82kB (885285 bits)
Date Submitted2018-12-24 00:00:00
Date Available2018-12-24 00:00:00
Creation Date2018-12-21 15:45:55
Producing SoftwareMicrosoft? Office Word 2007
Document Lastmod2018-12-21 15:45:55
Document TitleTest Report 1
Document CreatorMicrosoft? Office Word 2007
Document Author: Mike Heckrotte

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Language                        : zh-CN
Tagged PDF                      : Yes
Title                           : 1
Author                          : Mike Heckrotte
Creator                         : Microsoft? Office Word 2007
Create Date                     : 2018:12:21 15:45:55+08:00
Modify Date                     : 2018:12:21 15:45:55+08:00
Producer                        : Microsoft? Office Word 2007