FCC ID 2AS9403
SGW6008 BLE WiFi Gateway
by SG Wireless Limited
Grantee Code: 2AS94 Product Code: 03
Latest application date: 2020-05-11
FCC ID Device Details
| FCC ID | 2AS9403 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AS94 |
| Product Code | 03 |
| Applicant Business | SG Wireless Limited |
| Related Domains | |
| Equipment Class | SGW6008 BLE WiFi Gateway |
| Test Firm | Shenzhen BALUN Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2020-05-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User_Manual | Users Manual | 2020-11-07 | PDF 1.8 MB |
| Internal_Photos | Internal Photos | 2020-11-07 | PDF 962.4 KB |
| External_Photos | External Photos | 2020-11-07 | PDF 582.1 KB |
| Label and Label_Location | ID Label/Location Info | 2020-05-11 | PDF 99.2 KB |
| Test_Setup_Photos | Test Setup Photos | 2020-11-07 | PDF 699.3 KB |
| BL-SZ2030185-601 DTS test report_BLE_rev1 | Test Report | 2020-05-11 | PDF 2.5 MB |
| BL-SZ2030185-602 DTS test report_2.4G WLAN | Test Report | 2020-05-11 | PDF 4.9 MB |
| Agent_Authorization_Rev_1.0 | Cover Letter(s) | 2020-05-11 | PDF 17.3 KB |
| FCC AuthorizationLetter | Cover Letter(s) | 2020-05-11 | PDF 73 KB |
| FCC_Long_Term_Only_Confidentiality_Request | Cover Letter(s) | 2020-05-11 | PDF 120 KB |
| BL-SZ2030185-701 FCC Exposure Evaluation_rev1 | RF Exposure Info | 2020-05-11 | PDF 110.6 KB |
| Block_diagram Metadata only | Block Diagram | PDF 292.9 KB | |
| SCH Metadata only | Schematics | PDF 170 KB | |
| Operational_Description Metadata only | Operational Description | PDF 112.1 KB |
Application Information
| Application ID | +SfgDsVNOEj7SU9la6BwOg== |
|---|---|
| Final Action Date | 2020-05-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028467744 |
| Model | 03 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | SGW6008 BLE WiFi Gateway |
| Responsible Party | Kenneth Wong, VP of Design and Development, KEN.WONG@SGWIRELESS.COM |
| Technical Contact | SG Wireless Limited, KEN.WONG@SGWIRELESS.COM |
| Test Firm | Hanson Lin, Shenzhen BALUN Technology Co., Ltd., Hanson.Lin@baluntek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 11/07/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| +SfgDsVNOEj7SU9la6BwOg== | 2020-05-11 | Original Equipment |
Grants
TCB Grant - Application +SfgDsVNOEj7SU9la6BwOg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/11/2020 Application Dated: 05/11/2020 |
| SG Wireless Limited |
| Unit 4, 5/F, Sun Fung Industrial Building |
| 8 Ma Kok Street, Tsuen Wan, New Territories |
| Hong Kong, Hong Kong |
| Attention: Kenneth Wong , VP of Design and Development |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AS9403 |
| Name of Grantee: | SG Wireless Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | SGW6008 BLE WiFi Gateway |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.01054 | |||
| 15C | 2412.0 - 2462.0 | 0.02748 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application +SfgDsVNOEj7SU9la6BwOg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SG Wireless Limited Unit 4, 5/F, Sun Fung Industrial Building 8 Ma Kok Street, Tsuen Wan, New Territories Hong Kong, Hong Kong |
Date of Grant: 05/11/2020 Application Dated: 05/11/2020 |
| Attention: Kenneth Wong , VP of Design and Development |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AS9403 |
| Name of Grantee: | SG Wireless Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | SGW6008 BLE WiFi Gateway |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.01054 | |||
| 15C | 2412.0 - 2462.0 | 0.02748 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |