FCC ID 2ASE7-BIOHB02CTM10
Data Terminal module
by BioIntelliSense, Inc.
Grantee Code: 2ASE7 Product Code: BIOHB02CTM10
Latest application date: 2021-11-01
FCC ID Device Details
| FCC ID | 2ASE7-BIOHB02CTM10 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ASE7 |
| Product Code | BIOHB02CTM10 |
| Applicant Business | BioIntelliSense, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Data Terminal module |
| Test Firm | Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 699.7-715.3 MHz | Class II permissive change or modification of presently authorized equipment | 2021-11-01 |
| 663.1-697.9 MHz | Change in identification of presently authorized equipment. Original FCC ID: RI7ME910G1WW Grant Date: 04/22/2021 | 2021-09-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual_rev4 | Users Manual | 2022-04-30 | PDF 594.7 KB |
| Internal Photos rev2 | Internal Photos | 2022-04-30 | PDF 1.2 MB |
| External Photos | External Photos | 2022-04-30 | PDF 299.9 KB |
| External photos rev2 | External Photos | 2021-09-21 | PDF 299.9 KB |
| Label sample and label location | ID Label/Location Info | 2021-11-01 | PDF 222.4 KB |
| Label Sample and Label Location rev | ID Label/Location Info | 2021-09-21 | PDF 185.5 KB |
| Test setup photos | Test Setup Photos | 2022-04-30 | PDF 640.7 KB |
| Test Report (Part 24) rev | Test Report | 2021-11-01 | PDF 2.5 MB |
| Test Report (Part 90) rev | Test Report | 2021-11-01 | PDF 1 MB |
| Test report (Part 22) rev | Test Report | 2021-11-01 | PDF 2.8 MB |
| Test report (Part 27) rev | Test Report | 2021-11-01 | PDF 4 MB |
| Cover Letter (Declaration letter for host) rev | Attestation Statements | 2021-11-01 | PDF 163.4 KB |
| Declaration letter for bands rev | Attestation Statements | 2021-11-01 | PDF 310.5 KB |
| Confidentiality Request (Long term) rev | Cover Letter(s) | 2021-11-01 | PDF 105.1 KB |
| Confidentiality request (Short term) | Cover Letter(s) | 2021-11-01 | PDF 179.9 KB |
| Cover Letter (Agent Authorization) | Cover Letter(s) | 2021-11-01 | PDF 181.5 KB |
| Cover Letter (Description of Change) rev | Cover Letter(s) | 2021-11-01 | PDF 281.5 KB |
| Agent Authorization rev | Cover Letter(s) | 2021-09-21 | PDF 45.1 KB |
| Change ID Authorization rev | Cover Letter(s) | 2021-09-21 | PDF 109.4 KB |
| Request for Change ID rev3 | Cover Letter(s) | 2021-09-21 | PDF 89.2 KB |
| Operational Description (48RRSG02.0GA-gerber) Metadata only | Operational Description | PDF 1.1 MB | |
| Operational Description (48RRSG02.0GA_LTE_Module_BOM) Metadata only | Operational Description | PDF 240.5 KB | |
| Operational Description (Ant Trace KDB 996369 D02 Module QA) rev2 Metadata only | Operational Description | PDF 393.3 KB |
Application Information
| Application ID | 5tnCStyXuhul9d06Yh/PBw== |
|---|---|
| Final Action Date | 2021-11-01 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0029432325 |
| Model | BIOHB02CTM10 |
| Frequency Range | 699.7-715.3 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Data Terminal module |
| Responsible Party | Tracy Cheng, Head of Manufacturing, Tracy@biointellisense.com |
| Agent | Andrea Andrea Andrea, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, andrea.hsia@bureauveritas.com |
| Test Firm | Eric Lin, Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch, eric-wp.lin@tw.bureauveritas.com |
| TCB Email | certification@nacsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 04/30/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change for adding a new antenna and changing the antenna trace layout as described in this filing. Output power listed is conducted. This grant is valid only when the module is installed in the grantee’s own host product. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.0 dBi for Band 2 and Band 25, 5.0 dBi for Band 4 and Band 66, 9.4 dBi for Band 5, 8.7 dBi for Band 12, 9.1 dBi for Band 13, 9.3 dBi for Band 26, 8.6 dBi for Band 85, 6.9 dBi for GPRS/EDGE 824-849MHz Band, 2.5 dBi for GPRS/EDGE 1850-1910MHz Band. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 5tnCStyXuhul9d06Yh/PBw== | 2021-11-01 | Class II permissive change or modification of presently authorized equipment |
| D3fBixBzdbFdKG1Ckkm7PA== | 2021-09-21 | Change in identification of presently authorized equipment. Original FCC ID: RI7ME910G1WW Grant Date: 04/22/2021 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 663.1-697.9 MHz | 0.15 | 2.5ppm | 128KG7D | 27 |
| 663.1-697.9 MHz | 0.15 | 2.5ppm | 184KG7D | 27 |
| 698.1-715.9 MHz | 0.19 | 2.5ppm | 128KG7D | 27 |
| 698.1-715.9 MHz | 0.23 | 2.5ppm | 184KG7D | 27 |
| 699.1-715.9 MHz | 0.19 | 2.5ppm | 128KG7D | 27 |
| 699.1-715.9 MHz | 0.23 | 2.5ppm | 184KG7D | 27 |
| 699.7-715.3 MHz | 0.22 | 2.5ppm | 1M10G7D | 27 |
| 699.7-715.3 MHz | 0.2 | 2.5ppm | 938KW7D | 27 |
| 700.5-713.5 MHz | 0.21 | 2.5ppm | 1M10G7D | 27 |
| 700.5-713.5 MHz | 0.21 | 2.5ppm | 940KW7D | 27 |
| 777.1-786.9 MHz | 0.19 | 2.5ppm | 129KG7D | 27 |
| 777.1-786.9 MHz | 0.23 | 2.5ppm | 184KG7D | 27 |
| 779.5-784.5 MHz | 0.2 | 2.5ppm | 1M10G7D | 27 |
| 779.5-784.5 MHz | 0.2 | 2.5ppm | 939KW7D | 27 |
| 814.1-823.9 MHz | 0.2 | 2.5ppm | 127KG7D | 9 |
| 814.1-823.9 MHz | 0.21 | 2.5ppm | 190KG7D | 9 |
| 814.7-823.3 MHz | 0.22 | 2.5ppm | 1M10G7D | 9 |
| 814.7-823.3 MHz | 0.21 | 2.5ppm | 925KW7D | 9 |
| 824.1-848.9 MHz | 0.19 | 2.5ppm | 129KG7D | 22H |
| 824.1-848.9 MHz | 0.21 | 2.5ppm | 190KG7D | 22H |
| 824.1-848.9 MHz | 0.24 | 2.5ppm | 132KG7D | 22H |
| 824.1-848.9 MHz | 0.22 | 2.5ppm | 191KG7D | 22H |
| 824.7-848.3 MHz | 0.22 | 2.5ppm | 1M10W7D | 22H |
| 824.7-848.3 MHz | 0.22 | 2.5ppm | 1M10G7D | 22H |
| 824.7-848.3 MHz | 0.23 | 2.5ppm | 1M10G7D | 22H |
| 824.7-848.3 MHz | 0.24 | 2.5ppm | 931KW7D | 22H |
| 897.6-900.4 MHz | 0.288 | 2.5ppm | 80K2G7D | 27 |
| 897.6-900.4 MHz | 0.303 | 2.5ppm | 193KG7D | 27 |
| 898.2-899.8 MHz | 0.266 | 2.5ppm | 1M10G7D | 27 |
| 898.2-899.8 MHz | 0.225 | 2.5ppm | 912KW7D | 27 |
| 1710.1-1754.9 MHz | 0.23 | 2.5ppm | 191KG7D | 27 |
| 1710.1-1779.9 MHz | 0.23 | 2.5ppm | 128KG7D | 27 |
| 1710.1-1779.9 MHz | 0.24 | 2.5ppm | 189KG7D | 27 |
| 1710.1-1754.9 MHz | 0.22 | 2.5ppm | 130KG7D | 27 |
| 1710.7-1754.3 MHz | 0.24 | 2.5ppm | 1M10G7D | 27 |
| 1710.7-1754.3 MHz | 0.23 | 2.5ppm | 940KW7D | 27 |
| 1710.7-1779.3 MHz | 0.24 | 2.5ppm | 1M11G7D | 27 |
| 1710.7-1779.3 MHz | 0.23 | 2.5ppm | 1M10W7D | 27 |
| 1850.1-1914.9 MHz | 0.22 | 2.5ppm | 129KG7D | 24E |
| 1850.1-1914.9 MHz | 0.23 | 2.5ppm | 191KG7D | 24E |
| 1850.1-1909.9 MHz | 0.24 | 2.5ppm | 191KG7D | 24E |
| 1850.2-1909.8 MHz | 1.1 | 2.5ppm | 246KGXW | 24E |
| 1850.2-1909.8 MHz | 0.47 | 2.5ppm | 247KG7W | 24E |
| 1850.7-1914.3 MHz | 0.23 | 2.5ppm | 1M11G7D | 24E |
| 1850.7-1914.3 MHz | 0.24 | 2.5ppm | 936KW7D | 24E |
| 1850.7-1909.3 MHz | 0.23 | 2.5ppm | 1M10G7D | 24E |
| 1850.7-1909.3 MHz | 0.23 | 2.5ppm | 926KW7D | 24E |
Grants
TCB Grant - Application D3fBixBzdbFdKG1Ckkm7PA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
North American EMC Certification Services Inc 24889 Ferguson Ave Maple Ridge, BC, Canada |
Date of Grant: 09/21/2021 Application Dated: 09/21/2021 |
| BioIntelliSense, Inc. |
| 570 El Camino Real #200 |
| Redwood City, CA 94063 |
| Attention: Tracy Cheng , Head of Manufacturing |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ASE7-BIOHB02CTM10 |
| Name of Grantee: | BioIntelliSense, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Data Terminal module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.1 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.61 | 2.5 PM | 248KG7W | |
| 24E | 1850.2 - 1909.8 | 1.1 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.47 | 2.5 PM | 247KG7W | |
| 24E | 1850.1 - 1909.9 | 0.21 | 2.5 PM | 127KG7D | |
| 24E | 1850.1 - 1909.9 | 0.24 | 2.5 PM | 191KG7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 926KW7D | |
| 27 | 1710.1 - 1754.9 | 0.22 | 2.5 PM | 130KG7D | |
| 27 | 1710.1 - 1754.9 | 0.23 | 2.5 PM | 191KG7D | |
| 27 | 1710.7 - 1754.3 | 0.24 | 2.5 PM | 1M10G7D | |
| 27 | 1710.7 - 1754.3 | 0.23 | 2.5 PM | 940KW7D | |
| 22H | 824.1 - 848.9 | 0.19 | 2.5 PM | 129KG7D | |
| 22H | 824.1 - 848.9 | 0.21 | 2.5 PM | 190KG7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10W7D | |
| 27 | 699.1 - 715.9 | 0.19 | 2.5 PM | 128KG7D | |
| 27 | 699.1 - 715.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 699.7 - 715.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 27 | 699.7 - 715.3 | 0.2 | 2.5 PM | 938KW7D | |
| 27 | 777.1 - 786.9 | 0.19 | 2.5 PM | 129KG7D | |
| 27 | 777.1 - 786.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 1M10G7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 939KW7D | |
| 24E | 1850.1 - 1914.9 | 0.22 | 2.5 PM | 129KG7D | |
| 24E | 1850.1 - 1914.9 | 0.23 | 2.5 PM | 191KG7D | |
| 24E | 1850.7 - 1914.3 | 0.23 | 2.5 PM | 1M11G7D | |
| 24E | 1850.7 - 1914.3 | 0.24 | 2.5 PM | 936KW7D | |
| 90 | 814.1 - 823.9 | 0.2 | 2.5 PM | 127KG7D | |
| 90 | 814.1 - 823.9 | 0.21 | 2.5 PM | 190KG7D | |
| 90 | 814.7 - 823.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 90 | 814.7 - 823.3 | 0.21 | 2.5 PM | 925KW7D | |
| 22H | 824.1 - 848.9 | 0.24 | 2.5 PM | 132KG7D | |
| 22H | 824.1 - 848.9 | 0.22 | 2.5 PM | 191KG7D | |
| 22H | 824.7 - 848.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.24 | 2.5 PM | 931KW7D | |
| 27 | 1710.1 - 1779.9 | 0.23 | 2.5 PM | 128KG7D | |
| 27 | 1710.1 - 1779.9 | 0.24 | 2.5 PM | 189KG7D | |
| 27 | 1710.7 - 1779.3 | 0.24 | 2.5 PM | 1M11G7D | |
| 27 | 1710.7 - 1779.3 | 0.23 | 2.5 PM | 1M10W7D | |
| 27 | 663.1 - 697.9 | 0.15 | 2.5 PM | 128KG7D | |
| 27 | 663.1 - 697.9 | 0.15 | 2.5 PM | 184KG7D | |
| 27 | 698.1 - 715.9 | 0.19 | 2.5 PM | 128KG7D | |
| 27 | 698.1 - 715.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 1M10G7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 940KW7D | |
| 27 | 897.6 - 900.4 | 0.288 | 2.5 PM | 80K2G7D | |
| 27 | 897.6 - 900.4 | 0.303 | 2.5 PM | 193KG7D | |
| 27 | 898.2 - 899.8 | 0.266 | 2.5 PM | 1M10G7D | |
| 27 | 898.2 - 899.8 | 0.225 | 2.5 PM | 912KW7D |
| Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM integrators. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.0 dBi for Band 2 and Band 25, 5.0 dBi for Band 4 and Band 66, 9.4 dBi for Band 5, 8.7 dBi for Band 12, 9.1 dBi for Band 13, 8.9dBi for Band 8, 9.3 dBi for Band 26, 8.6 dBi for Band 85, 11.4 dBi for Band 71, 6.9 dBi for GPRS/EDGE 824-849MHz Band, 2.5 dBi for GPRS/EDGE 1850-1910MHz Band. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
EAS Grant - Application D3fBixBzdbFdKG1Ckkm7PA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BioIntelliSense, Inc. 570 El Camino Real #200 Redwood City, CA 94063 United States |
Date of Grant: 09/21/2021 Application Dated: 09/21/2021 |
| Attention: Tracy Cheng , Head of Manufacturing |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ASE7-BIOHB02CTM10 |
| Name of Grantee: | BioIntelliSense, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Data Terminal module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.1 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.61 | 2.5 PM | 248KG7W | |
| 24E | 1850.2 - 1909.8 | 1.1 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.47 | 2.5 PM | 247KG7W | |
| 24E | 1850.1 - 1909.9 | 0.21 | 2.5 PM | 127KG7D | |
| 24E | 1850.1 - 1909.9 | 0.24 | 2.5 PM | 191KG7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 926KW7D | |
| 27 | 1710.1 - 1754.9 | 0.22 | 2.5 PM | 130KG7D | |
| 27 | 1710.1 - 1754.9 | 0.23 | 2.5 PM | 191KG7D | |
| 27 | 1710.7 - 1754.3 | 0.24 | 2.5 PM | 1M10G7D | |
| 27 | 1710.7 - 1754.3 | 0.23 | 2.5 PM | 940KW7D | |
| 22H | 824.1 - 848.9 | 0.19 | 2.5 PM | 129KG7D | |
| 22H | 824.1 - 848.9 | 0.21 | 2.5 PM | 190KG7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10W7D | |
| 27 | 699.1 - 715.9 | 0.19 | 2.5 PM | 128KG7D | |
| 27 | 699.1 - 715.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 699.7 - 715.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 27 | 699.7 - 715.3 | 0.2 | 2.5 PM | 938KW7D | |
| 27 | 777.1 - 786.9 | 0.19 | 2.5 PM | 129KG7D | |
| 27 | 777.1 - 786.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 1M10G7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 939KW7D | |
| 24E | 1850.1 - 1914.9 | 0.22 | 2.5 PM | 129KG7D | |
| 24E | 1850.1 - 1914.9 | 0.23 | 2.5 PM | 191KG7D | |
| 24E | 1850.7 - 1914.3 | 0.23 | 2.5 PM | 1M11G7D | |
| 24E | 1850.7 - 1914.3 | 0.24 | 2.5 PM | 936KW7D | |
| 90 | 814.1 - 823.9 | 0.2 | 2.5 PM | 127KG7D | |
| 90 | 814.1 - 823.9 | 0.21 | 2.5 PM | 190KG7D | |
| 90 | 814.7 - 823.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 90 | 814.7 - 823.3 | 0.21 | 2.5 PM | 925KW7D | |
| 22H | 824.1 - 848.9 | 0.24 | 2.5 PM | 132KG7D | |
| 22H | 824.1 - 848.9 | 0.22 | 2.5 PM | 191KG7D | |
| 22H | 824.7 - 848.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.24 | 2.5 PM | 931KW7D | |
| 27 | 1710.1 - 1779.9 | 0.23 | 2.5 PM | 128KG7D | |
| 27 | 1710.1 - 1779.9 | 0.24 | 2.5 PM | 189KG7D | |
| 27 | 1710.7 - 1779.3 | 0.24 | 2.5 PM | 1M11G7D | |
| 27 | 1710.7 - 1779.3 | 0.23 | 2.5 PM | 1M10W7D | |
| 27 | 663.1 - 697.9 | 0.15 | 2.5 PM | 128KG7D | |
| 27 | 663.1 - 697.9 | 0.15 | 2.5 PM | 184KG7D | |
| 27 | 698.1 - 715.9 | 0.19 | 2.5 PM | 128KG7D | |
| 27 | 698.1 - 715.9 | 0.23 | 2.5 PM | 184KG7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 1M10G7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 940KW7D | |
| 27 | 897.6 - 900.4 | 0.288 | 2.5 PM | 80K2G7D | |
| 27 | 897.6 - 900.4 | 0.303 | 2.5 PM | 193KG7D | |
| 27 | 898.2 - 899.8 | 0.266 | 2.5 PM | 1M10G7D | |
| 27 | 898.2 - 899.8 | 0.225 | 2.5 PM | 912KW7D |
| Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM integrators. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.0 dBi for Band 2 and Band 25, 5.0 dBi for Band 4 and Band 66, 9.4 dBi for Band 5, 8.7 dBi for Band 12, 9.1 dBi for Band 13, 8.9dBi for Band 8, 9.3 dBi for Band 26, 8.6 dBi for Band 85, 11.4 dBi for Band 71, 6.9 dBi for GPRS/EDGE 824-849MHz Band, 2.5 dBi for GPRS/EDGE 1850-1910MHz Band. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
North American EMC Certification Services Inc 24889 Ferguson Ave Maple Ridge, BC, Canada |
Date of Grant: 11/01/2021 Application Dated: 10/29/2021 |
| BioIntelliSense, Inc. |
| 570 El Camino Real #200 |
| Redwood City, CA 94063 |
| Attention: Tracy Cheng , Head of Manufacturing |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ASE7-BIOHB02CTM10 |
| Name of Grantee: | BioIntelliSense, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Data Terminal module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.1 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.61 | 2.5 PM | 248KG7W | |
| 24E | 1850.2 - 1909.8 | 1.1 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.47 | 2.5 PM | 247KG7W | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 926KW7D | |
| 27 | 1710.7 - 1754.3 | 0.24 | 2.5 PM | 1M10G7D | |
| 27 | 1710.7 - 1754.3 | 0.23 | 2.5 PM | 940KW7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10W7D | |
| 27 | 699.7 - 715.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 27 | 699.7 - 715.3 | 0.2 | 2.5 PM | 938KW7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 1M10G7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 939KW7D | |
| 24E | 1850.7 - 1914.3 | 0.23 | 2.5 PM | 1M11G7D | |
| 24E | 1850.7 - 1914.3 | 0.24 | 2.5 PM | 936KW7D | |
| 90 | 814.7 - 823.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 90 | 814.7 - 823.3 | 0.21 | 2.5 PM | 925KW7D | |
| 22H | 824.7 - 848.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.24 | 2.5 PM | 931KW7D | |
| 27 | 1710.7 - 1779.3 | 0.24 | 2.5 PM | 1M11G7D | |
| 27 | 1710.7 - 1779.3 | 0.23 | 2.5 PM | 1M10W7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 1M10G7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 940KW7D |
| Class II Permissive Change for adding a new antenna and changing the antenna trace layout as described in this filing. Output power listed is conducted. This grant is valid only when the module is installed in the grantees own host product. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.0 dBi for Band 2 and Band 25, 5.0 dBi for Band 4 and Band 66, 9.4 dBi for Band 5, 8.7 dBi for Band 12, 9.1 dBi for Band 13, 9.3 dBi for Band 26, 8.6 dBi for Band 85, 6.9 dBi for GPRS/EDGE 824-849MHz Band, 2.5 dBi for GPRS/EDGE 1850-1910MHz Band. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
EAS Grant - Application 5tnCStyXuhul9d06Yh/PBw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BioIntelliSense, Inc. 570 El Camino Real #200 Redwood City, CA 94063 United States |
Date of Grant: 11/01/2021 Application Dated: 10/29/2021 |
| Attention: Tracy Cheng , Head of Manufacturing |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ASE7-BIOHB02CTM10 |
| Name of Grantee: | BioIntelliSense, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Data Terminal module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.1 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 848.8 | 0.61 | 2.5 PM | 248KG7W | |
| 24E | 1850.2 - 1909.8 | 1.1 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.47 | 2.5 PM | 247KG7W | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 24E | 1850.7 - 1909.3 | 0.23 | 2.5 PM | 926KW7D | |
| 27 | 1710.7 - 1754.3 | 0.24 | 2.5 PM | 1M10G7D | |
| 27 | 1710.7 - 1754.3 | 0.23 | 2.5 PM | 940KW7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.22 | 2.5 PM | 1M10W7D | |
| 27 | 699.7 - 715.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 27 | 699.7 - 715.3 | 0.2 | 2.5 PM | 938KW7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 1M10G7D | |
| 27 | 779.5 - 784.5 | 0.2 | 2.5 PM | 939KW7D | |
| 24E | 1850.7 - 1914.3 | 0.23 | 2.5 PM | 1M11G7D | |
| 24E | 1850.7 - 1914.3 | 0.24 | 2.5 PM | 936KW7D | |
| 90 | 814.7 - 823.3 | 0.22 | 2.5 PM | 1M10G7D | |
| 90 | 814.7 - 823.3 | 0.21 | 2.5 PM | 925KW7D | |
| 22H | 824.7 - 848.3 | 0.23 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.24 | 2.5 PM | 931KW7D | |
| 27 | 1710.7 - 1779.3 | 0.24 | 2.5 PM | 1M11G7D | |
| 27 | 1710.7 - 1779.3 | 0.23 | 2.5 PM | 1M10W7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 1M10G7D | |
| 27 | 700.5 - 713.5 | 0.21 | 2.5 PM | 940KW7D |
| Class II Permissive Change for adding a new antenna and changing the antenna trace layout as described in this filing. Output power listed is conducted. This grant is valid only when the module is installed in the grantees own host product. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.0 dBi for Band 2 and Band 25, 5.0 dBi for Band 4 and Band 66, 9.4 dBi for Band 5, 8.7 dBi for Band 12, 9.1 dBi for Band 13, 9.3 dBi for Band 26, 8.6 dBi for Band 85, 6.9 dBi for GPRS/EDGE 824-849MHz Band, 2.5 dBi for GPRS/EDGE 1850-1910MHz Band. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
| Mail To: |