FCC ID 2ASK2-SUTO-002

S415 Thermal Mass Flow Sensor

by SUTO iTEC (Asia) Co. Limited

Grantee Code: 2ASK2   Product Code: SUTO002
Latest application date: 2019-05-15

FCC ID Device Details

FCC ID2ASK2-SUTO-002
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASK2
Product CodeSUTO002
Applicant BusinessSUTO iTEC (Asia) Co. Limited 🇨🇳
Related Domains suto-itec.asia
Equipment ClassS415 Thermal Mass Flow Sensor
Test FirmShenzhen BALUN Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-05-15

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2019-05-15PDF 768 KB
Internal PhotosInternal Photos2019-05-15PDF 4.1 MB
External PhotosExternal Photos2019-05-15PDF 446.5 KB
labelID Label/Location Info2019-05-15PDF 84.6 KB
test setup photosTest Setup Photos2019-05-15PDF 802.5 KB
Test ReportTest Report2019-05-15PDF 2.3 MB
POACover Letter(s)2019-05-15PDF 1.3 MB
confidentiality request letterCover Letter(s)2019-05-15PDF 1.4 MB
rf exposureRF Exposure Info2019-05-15PDF 118.8 KB

Application Information

Application IDLp8kIbBP/iEnPxbQ2LeVZg==
Final Action Date2019-05-15
Application PurposeOriginal Equipment
Applicant FRN0028269603
Model-SUTO-002
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionS415 Thermal Mass Flow Sensor
Responsible PartyLecy Li, Quality Manager, Lecy.Li@suto-itec.asia , 8618938630093
Test FirmHao Qi, Shenzhen BALUN Technology Co., Ltd., qih@baluntek.com , 086-755-66833407
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum conducted output power. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing.

Applications

Application IDDatePurpose
Lp8kIbBP/iEnPxbQ2LeVZg==2019-05-15Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000870015C

Grants

TCB Grant - Application Lp8kIbBP/iEnPxbQ2LeVZg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 05/15/2019

Application Dated: 05/15/2019
SUTO iTEC (Asia) Co. Limited
Rm 10, 6/F, Block B, Cambridge Plaza,
188 San Wan Road, Sheung Shui, N.T.
Hong Kong,
China
 
Attention: Lecy Li , Quality Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASK2-SUTO-002
Name of Grantee:  SUTO iTEC (Asia) Co. Limited
Equipment Class: Digital Transmission System
Notes: S415 Thermal Mass Flow Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00087  

Output Power listed is the maximum conducted output power. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing.

EAS Grant - Application Lp8kIbBP/iEnPxbQ2LeVZg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SUTO iTEC (Asia) Co. Limited
Rm 10, 6/F, Block B, Cambridge Plaza, 188 San Wan Road, Sheung Shui, N.T.
Hong Kong,
China
  Date of Grant: 05/15/2019

Application Dated: 05/15/2019
 
Attention: Lecy Li , Quality Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASK2-SUTO-002
Name of Grantee:  SUTO iTEC (Asia) Co. Limited
Equipment Class: Digital Transmission System
Notes: S415 Thermal Mass Flow Sensor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00087  

Output Power listed is the maximum conducted output power. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing.



Mail To: