FCC ID 2ASK2-SUTO-006

S431 Compressor Flow Meter

by SUTO iTEC (Asia) Co. Limited

Grantee Code: 2ASK2   Product Code: SUTO006
Latest application date: 2022-06-17

FCC ID Device Details

FCC ID2ASK2-SUTO-006
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASK2
Product CodeSUTO006
Applicant BusinessSUTO iTEC (Asia) Co. Limited 🇨🇳
Related Domains suto-itec.asia ntek.org.cn
Equipment ClassS431 Compressor Flow Meter
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-06-17

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-12-15PDF 4.3 MB
Internal photosInternal Photos2022-12-15PDF 966.9 KB
External photosExternal Photos2022-06-17PDF 536.2 KB
ID label and locationID Label/Location Info2022-06-17PDF 3.9 MB
Test setup photosTest Setup Photos2022-12-15PDF 286.8 KB
Test reportsTest Report2022-06-17PDF 2.1 MB
SDoCAttestation Statements2022-06-17PDF 124.5 KB
ConfidentialityCover Letter(s)2022-06-17PDF 114.6 KB
Letter AuthorizationCover Letter(s)2022-06-17PDF 60.9 KB
RF ExposureRF Exposure Info2022-06-17PDF 259.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 76.4 KB
Schematics Metadata onlySchematicsPDF 583.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 91.8 KB

Application Information

Application IDGeX3HseyxlqmZNI8CHQg2w==
Final Action Date2022-06-17
Application PurposeOriginal Equipment
Applicant FRN0028269603
ModelSUTO-006
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionS431 Compressor Flow Meter
Responsible PartyLecy Li, Quality Manager, Lecy.Li@suto-itec.asia , 8618938630093
Technical ContactAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., alex.li@ntek.org.cn , 86-755-6115 6588
Non-Technical ContactAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., alex.li@ntek.org.cn , 86-755-6115 6588
Test FirmAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn , +86-755-6115-9384
TCB Emailelabscert@applus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/15/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
GeX3HseyxlqmZNI8CHQg2w==2022-06-17Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000970015C

Grants

TCB Grant - Application GeX3HseyxlqmZNI8CHQg2w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 06/17/2022

Application Dated: 06/17/2022
SUTO iTEC (Asia) Co. Limited
Rm 10, 6/F, Block B, Cambridge Plaza,
188 San Wan Road, Sheung Shui, N.T.
Hong Kong,
China
 
Attention: Lecy Li , Quality Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASK2-SUTO-006
Name of Grantee:  SUTO iTEC (Asia) Co. Limited
Equipment Class: Digital Transmission System
Notes: S431 Compressor Flow Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00097  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application GeX3HseyxlqmZNI8CHQg2w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SUTO iTEC (Asia) Co. Limited
Rm 10, 6/F, Block B, Cambridge Plaza, 188 San Wan Road, Sheung Shui, N.T.
Hong Kong,
China
  Date of Grant: 06/17/2022

Application Dated: 06/17/2022
 
Attention: Lecy Li , Quality Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASK2-SUTO-006
Name of Grantee:  SUTO iTEC (Asia) Co. Limited
Equipment Class: Digital Transmission System
Notes: S431 Compressor Flow Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00097  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: