FCC ID 2ASKHBT01

DoorSense

by PHILLIPS CONNECT TECHNOLOGIES LLC

Grantee Code: 2ASKH   Product Code: BT01
Latest application date: 2020-07-14

FCC ID Device Details

FCC ID2ASKHBT01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASKH
Product CodeBT01
Applicant BusinessPHILLIPS CONNECT TECHNOLOGIES LLC 🇺🇸
Related Domains phillips-connect.com
Equipment ClassDoorSense
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2020-07-14

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2020-07-14PDF 71.6 KB
Internal PhotosInternal Photos2020-07-14PDF 945.7 KB
External PhotosExternal Photos2020-07-14PDF 460.2 KB
Label & Label LocationID Label/Location Info2020-07-14PDF 84.6 KB
Test setup photosTest Setup Photos2020-07-14PDF 222.9 KB
Appendix A Test Data for BLETest Report2020-07-14PDF 2 MB
Test Report-DTS-BLETest Report2020-07-14PDF 1.1 MB
Declaration Letter of Model DifferenceCover Letter(s)2020-07-14PDF 26.9 KB
FCC Confidentiality request letterCover Letter(s)2020-07-14PDF 99.8 KB
FCC POACover Letter(s)2020-07-14PDF 65.6 KB
RF Exposure Info-MPERF Exposure Info2020-07-14PDF 254.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 37.4 KB
Schematic Metadata onlySchematicsPDF 172 KB
Declaration concerning Antenna Specification Metadata onlyOperational DescriptionPDF 71.2 KB
Operation Description Metadata onlyOperational DescriptionPDF 194 KB

Application Information

Application IDwihtsZCOu6ojPhtqP4CRNQ==
Final Action Date2020-07-14
Application PurposeOriginal Equipment
Applicant FRN0028264505
ModelBT01
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionDoorSense
Responsible PartyDoug Reauso, Project Manager, dreauso@phillips-connect.com , +17149316998
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailjoergkusig@eurofins.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
wihtsZCOu6ojPhtqP4CRNQ==2020-07-14Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001200015C

Grants

TCB Grant - Application wihtsZCOu6ojPhtqP4CRNQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 07/14/2020

Application Dated: 07/14/2020
PHILLIPS CONNECT TECHNOLOGIES LLC
5231 California Avenue, Suite 110
Irvine, CA 92617
 
Attention: Doug Reauso , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASKHBT01
Name of Grantee:  PHILLIPS CONNECT TECHNOLOGIES LLC
Equipment Class: Digital Transmission System
Notes: DoorSense
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output Power listed is peak conducted.

RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.


EAS Grant - Application wihtsZCOu6ojPhtqP4CRNQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PHILLIPS CONNECT TECHNOLOGIES LLC
5231 California Avenue, Suite 110
Irvine, CA 92617
United States
  Date of Grant: 07/14/2020

Application Dated: 07/14/2020
 
Attention: Doug Reauso , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASKHBT01
Name of Grantee:  PHILLIPS CONNECT TECHNOLOGIES LLC
Equipment Class: Digital Transmission System
Notes: DoorSense
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output Power listed is peak conducted.

RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: