FCC ID 2ASR8SC3832

Touch screen main control board

by Qingdao Haier Biomedical Co Ltd

Grantee Code: 2ASR8   Product Code: SC3832
Latest application date: 2019-05-08

FCC ID Device Details

FCC ID2ASR8SC3832
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASR8
Product CodeSC3832
Applicant BusinessQingdao Haier Biomedical Co Ltd 🇨🇳
Related Domains haierbiomedical.com mrt-cert.com
Equipment ClassTouch screen main control board
Test FirmMRT Technology (Suzhou) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-05-08
2402-2480 MHzOriginal Equipment2019-05-08

Exhibits

DocumentTypeAvailableFile
2ASR8SC3832_User-ManualUsers Manual2019-05-08PDF 563.9 KB
1902RSU012-UE-Internal-PhotographInternal Photos2019-05-08PDF 1.2 MB
1902RSU012-UE-External-PhotographExternal Photos2019-05-08PDF 811.8 KB
2ASR8SC3832_Label and Label locationID Label/Location Info2019-05-08PDF 207 KB
1902RSU012-UTTest Setup Photos2019-05-08PDF 502.6 KB
1902RSU012-U1-FCC-DTS-Test-Report-Wi-FiTest Report2019-05-08PDF 4.8 MB
1902RSU012-U2-FCC DSS Test Report (Bluetooth)_Part1Test Report2019-05-08PDF 3.6 MB
1902RSU012-U2-FCC DSS Test Report (Bluetooth)_Part2Test Report2019-05-08PDF 2.7 MB
1902RSU012-U3-FCC-DTS-Test-Report-Bluetooth-LETest Report2019-05-08PDF 2.4 MB
2ASR8SC3832_AttestationAttestation Statements2019-05-08PDF 27.8 KB
2ASR8SC3832_FCC_Declaration_of_authorizationCover Letter(s)2019-05-08PDF 17.1 KB
2ASR8SC3832_FCC_Letter_for_ConfidentialityCover Letter(s)2019-05-08PDF 22.6 KB
2ASR8SC3832_Modular-Approval-LetterCover Letter(s)2019-05-08PDF 46.9 KB
1902RSU012-U4-RF-Exposure-ReportRF Exposure Info2019-05-08PDF 155.9 KB
1902RSU012-UE-External-Photograph Metadata onlyRF Exposure Info2019-05-08PDF 811.8 KB
2ASR8SC3832_Block-Diagram Metadata onlyBlock DiagramPDF 37.1 KB
2ASR8SC3832_Schematics Metadata onlySchematicsPDF 368 KB
2ASR8SC3832_Operation-Description Metadata onlyOperational DescriptionPDF 66 KB

Application Information

Application IDjnJTN+xDTAUA5kw08a4UYA==
Final Action Date2019-05-08
Application PurposeOriginal Equipment
Applicant FRN0028335453
ModelSC3832
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionTouch screen main control board
Responsible PartyYuqiang Sun, Yuqiang.Sun@haierbiomedical.com , 86-15550094789
AgentMarlin Marlin Marlin, MRT Technology (Suzhou) Co., Ltd, marlinchen@mrt-cert.com , 86-512-66308358
Technical ContactMarlin Chen, MRT Technology (Suzhou) Co., Ltd, marlinchen@mrt-cert.com , 86-512-66308358
Non-Technical ContactMarlin Chen, MRT Technology (Suzhou) Co., Ltd, marlinchen@mrt-cert.com , 86-512-66308358
Test FirmMr. Marlin Chen, MRT Technology (Suzhou) Co., Ltd., marlinchen@mrt-cert.com , +86-512-66308358
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. Modular Approval. This device is granted for use in Mobile only configurations in which the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains Bluetooth transmitter.

Applications

Application IDDatePurpose
jnJTN+xDTAUA5kw08a4UYA==2019-05-08Original Equipment
JA4L+n3NMIrCDziGqlmEjw==2019-05-08Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.008000015CCC
2402-2480 MHz0.006515CCC
2412-2462 MHz0.272915CCC

Grants

TCB Grant - Application jnJTN+xDTAUA5kw08a4UYA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 05/08/2019

Application Dated: 05/06/2019
Qingdao Haier Biomedical Co Ltd
HAIER INDUSTRIAL PARK ECONOMIC
TECHNOLOGY DEVELOPMENT ZONE
QINGDAO, 266510
China
 
Attention: Yuqiang Sun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASR8SC3832
Name of Grantee:  Qingdao Haier Biomedical Co Ltd
Equipment Class: Digital Transmission System
Notes: Touch screen main control board
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0065  
CC 15C 2412.0  -  2462.0 0.2729  

Power Output listed is Conducted. Modular Approval. This device is granted for use in Mobile only configurations in which the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains Bluetooth transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application jnJTN+xDTAUA5kw08a4UYA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Qingdao Haier Biomedical Co Ltd
HAIER INDUSTRIAL PARK ECONOMIC TECHNOLOGY DEVELOPMENT ZONE
QINGDAO, 266510
China
  Date of Grant: 05/08/2019

Application Dated: 05/06/2019
 
Attention: Yuqiang Sun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASR8SC3832
Name of Grantee:  Qingdao Haier Biomedical Co Ltd
Equipment Class: Digital Transmission System
Notes: Touch screen main control board
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0065  
CC 15C 2412.0  -  2462.0 0.2729  

Power Output listed is Conducted. Modular Approval. This device is granted for use in Mobile only configurations in which the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains Bluetooth transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application JA4L+n3NMIrCDziGqlmEjw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 05/08/2019

Application Dated: 05/06/2019
Qingdao Haier Biomedical Co Ltd
HAIER INDUSTRIAL PARK ECONOMIC
TECHNOLOGY DEVELOPMENT ZONE
QINGDAO, 266510
China
 
Attention: Yuqiang Sun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASR8SC3832
Name of Grantee:  Qingdao Haier Biomedical Co Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Touch screen main control board
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  

Power Output listed is Conducted. Modular Approval. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains BLE and WLAN transmitters.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application JA4L+n3NMIrCDziGqlmEjw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Qingdao Haier Biomedical Co Ltd
HAIER INDUSTRIAL PARK ECONOMIC TECHNOLOGY DEVELOPMENT ZONE
QINGDAO, 266510
China
  Date of Grant: 05/08/2019

Application Dated: 05/06/2019
 
Attention: Yuqiang Sun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASR8SC3832
Name of Grantee:  Qingdao Haier Biomedical Co Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Touch screen main control board
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  

Power Output listed is Conducted. Modular Approval. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains BLE and WLAN transmitters.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: