FCC ID 2ASYE-T-HMI

T-HMI

by Shenzhen Xin Yuan Electronic Technology Co., Ltd.

Grantee Code: 2ASYE   Product Code: THMI
Latest application date: 2023-05-26

FCC ID Device Details

FCC ID2ASYE-T-HMI
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASYE
Product CodeTHMI
Applicant BusinessShenzhen Xin Yuan Electronic Technology Co., Ltd. 🇨🇳
Related Domains lilygo.cc
Equipment ClassT-HMI
Test FirmShenzhen Accurate Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2472 MHzOriginal Equipment2023-05-26

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-05-26PDF 2.3 MB
Internal PhotosInternal Photos2023-05-26PDF 646.4 KB
External PhotosExternal Photos2023-05-26PDF 1.2 MB
E-Label InformationID Label/Location Info2023-05-26PDF 317.4 KB
Test Setup PhotosTest Setup Photos2023-05-26PDF 412.4 KB
Antenna SpecificationTest Report2023-05-26PDF 1 MB
Test ReportTest Report2023-05-26PDF 3.7 MB
2.911 (d)(5)(i) Attestation StatementAttestation Statements2023-05-26PDF 129.4 KB
2.911 (d)(5)(ii) Attestation StatementAttestation Statements2023-05-26PDF 133.7 KB
US Agent Attestation LetterAttestation Statements2023-05-26PDF 110.9 KB
FCC Agent Authorization LetterCover Letter(s)2023-05-26PDF 13 KB
FCC Long-term Confidential RequestCover Letter(s)2023-05-26PDF 79 KB
RF ExposureRF Exposure Info2023-05-26PDF 182.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 68.1 KB
Schematics Metadata onlySchematicsPDF 307.3 KB
Circuit Description Metadata onlyOperational DescriptionPDF 92.4 KB

Application Information

Application IDAF67ORhW2SNXkTvYiJQshw==
Final Action Date2023-05-26
Application PurposeOriginal Equipment
Applicant FRN0028379253
ModelT-HMI
Frequency Range2412-2472 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionT-HMI
Responsible PartyYashon Zhang, Product Manager, zhang@lilygo.cc , 0755-83380665
Test FirmLisa Zhang, Shenzhen Accurate Technology Co., Ltd., qa@atc-lab.com , +86-755-26503290
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Applications

Application IDDatePurpose
AF67ORhW2SNXkTvYiJQshw==2023-05-26Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.00215C
2412-2472 MHz0.02615C

Grants

TCB Grant - Application AF67ORhW2SNXkTvYiJQshw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 05/26/2023

Application Dated: 05/26/2023
Shenzhen Xin Yuan Electronic Technology Co., Ltd.
401 4F Bldg.building B. No.5, 1st Rd
Bantianshangxue Technology Park, Bantian St
Longgang Dist., Shenzhen, Guangdong,
China
 
Attention: Yashon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASYE-T-HMI
Name of Grantee:  Shenzhen Xin Yuan Electronic Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: T-HMI
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  
15C 2412.0  -  2472.0 0.026  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

EAS Grant - Application AF67ORhW2SNXkTvYiJQshw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Xin Yuan Electronic Technology Co., Ltd.
401 4F Bldg.building B. No.5, 1st Rd Bantianshangxue Technology Park, Bantian St
Longgang Dist., Shenzhen, Guangdong,
China
  Date of Grant: 05/26/2023

Application Dated: 05/26/2023
 
Attention: Yashon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASYE-T-HMI
Name of Grantee:  Shenzhen Xin Yuan Electronic Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: T-HMI
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  
15C 2412.0  -  2472.0 0.026  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.



Mail To: