FCC ID 2ASYE-T-QT-PRO

T-QT Pro

by Shenzhen Xin Yuan Electronic Technology Co., Ltd.

Grantee Code: 2ASYE   Product Code: TQTPRO
Latest application date: 2022-12-31

FCC ID Device Details

FCC ID2ASYE-T-QT-PRO
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ASYE
Product CodeTQTPRO
Applicant BusinessShenzhen Xin Yuan Electronic Technology Co., Ltd. 🇨🇳
Related Domains lilygo.cc
Equipment ClassT-QT Pro
Test FirmShenzhen Accurate Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2472 MHzOriginal Equipment2022-12-31

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-12-31PDF 1.1 MB
Internal PhotosInternal Photos2022-12-31PDF 1.8 MB
External PhotosExternal Photos2022-12-31PDF 195 KB
E-Label InformationID Label/Location Info2022-12-31PDF 772.9 KB
Test Setup PhotosTest Setup Photos2022-12-31PDF 380.4 KB
Antenna ReportTest Report2022-12-31PDF 652.3 KB
Test ReportTest Report2022-12-31PDF 3.1 MB
FCC Agent Authorization LetterCover Letter(s)2022-12-31PDF 87.9 KB
FCC Long-term Confidential AuthorizationCover Letter(s)2022-12-31PDF 92.2 KB
RF ExposureRF Exposure Info2022-12-31PDF 181.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 160 KB
Schematics Metadata onlySchematicsPDF 291.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 97.5 KB

Application Information

Application IDFtUroW6hNpjdXJdUtnQefA==
Final Action Date2022-12-31
Application PurposeOriginal Equipment
Applicant FRN0028379253
ModelT-QT-PRO
Frequency Range2412-2472 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionT-QT Pro
Responsible PartyYashon Zhang, Product Manager, zhang@lilygo.cc , 0755-83380665
Test FirmLisa Zhang, Shenzhen Accurate Technology Co., Ltd., qa@atc-lab.com , +86-755-26503290
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Applications

Application IDDatePurpose
FtUroW6hNpjdXJdUtnQefA==2022-12-31Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.01515C
2412-2472 MHz0.04315C

Grants

TCB Grant - Application FtUroW6hNpjdXJdUtnQefA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/31/2022

Application Dated: 12/31/2022
Shenzhen Xin Yuan Electronic Technology Co., Ltd.
401 4F Bldg.building B. No.5, 1st Rd
Bantianshangxue Technology Park, Bantian St
Longgang Dist., Shenzhen, Guangdong,
China
 
Attention: Yashon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASYE-T-QT-PRO
Name of Grantee:  Shenzhen Xin Yuan Electronic Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: T-QT Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2472.0 0.043  
15C 2402.0  -  2480.0 0.015  

Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

EAS Grant - Application FtUroW6hNpjdXJdUtnQefA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Xin Yuan Electronic Technology Co., Ltd.
401 4F Bldg.building B. No.5, 1st Rd Bantianshangxue Technology Park, Bantian St
Longgang Dist., Shenzhen, Guangdong,
China
  Date of Grant: 12/31/2022

Application Dated: 12/31/2022
 
Attention: Yashon Zhang , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ASYE-T-QT-PRO
Name of Grantee:  Shenzhen Xin Yuan Electronic Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: T-QT Pro
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2472.0 0.043  
15C 2402.0  -  2480.0 0.015  

Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.



Mail To: