FCC ID 2AT3R-PT311PW2
WIFI CAM
by Shenzhen Axischina Technology Co, Ltd
Grantee Code: 2AT3R Product Code: PT311PW2
Latest application date: 2019-10-18
FCC ID Device Details
| FCC ID | 2AT3R-PT311PW2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AT3R |
| Product Code | PT311PW2 |
| Applicant Business | Shenzhen Axischina Technology Co, Ltd 🇨🇳 |
| Equipment Class | WIFI CAM |
| Test Firm | Shenzhen HUAK Testing Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2019-10-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual Part1 | Users Manual | 2019-10-18 | PDF 5.8 MB |
| User Manual Part2 | Users Manual | 2019-10-18 | PDF 5.3 MB |
| Internal Photos | Internal Photos | 2019-10-18 | PDF 1.1 MB |
| External Photos | External Photos | 2019-10-18 | PDF 684.4 KB |
| Label & Label Location | ID Label/Location Info | 2019-10-18 | PDF 195.2 KB |
| Test Setup Photos | Test Setup Photos | 2019-10-18 | PDF 368.8 KB |
| Test Report-DTS | Test Report | 2019-10-18 | PDF 4.5 MB |
| FCC Confidentiality request letter | Cover Letter(s) | 2019-10-18 | PDF 82.4 KB |
| FCC Declaration of Disable WLAN Channel 12 and 13 | Cover Letter(s) | 2019-10-18 | PDF 141 KB |
| FCC POA | Cover Letter(s) | 2019-10-18 | PDF 9.3 KB |
| FCC RF Exposure-MPE | RF Exposure Info | 2019-10-18 | PDF 88.8 KB |
| Block Diagram Metadata only | Block Diagram | PDF 27.3 KB | |
| Schematic Metadata only | Schematics | PDF 166.9 KB | |
| Declaration concerning Antenna Specification Metadata only | Operational Description | PDF 58.1 KB | |
| Operation description Metadata only | Operational Description | PDF 91.4 KB |
Application Information
| Application ID | qAf/WO7d9cD0EKULcn/fTg== |
|---|---|
| Final Action Date | 2019-10-18 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028667269 |
| Model | PT311PW2 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | WIFI CAM |
| Responsible Party | Huang HaoYou, huanghaoyou@126.com |
| Test Firm | Jason Zhou, Shenzhen HUAK Testing Technology Co., Ltd., jason@cer-mark.com |
| TCB Email | joergkusig@eurofins.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| qAf/WO7d9cD0EKULcn/fTg== | 2019-10-18 | Original Equipment |
Grants
TCB Grant - Application qAf/WO7d9cD0EKULcn/fTg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 10/18/2019 Application Dated: 10/17/2019 |
| Shenzhen Axischina Technology Co, Ltd |
| 3rd Floor,No 270,Jieling New Village,Dashuikeng |
| Community,Fucheng Street,Longhua District,Shenzhen |
| Shenzhen, China |
| Attention: Huang HaoYou |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AT3R-PT311PW2 |
| Name of Grantee: | Shenzhen Axischina Technology Co, Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | WIFI CAM |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.162 | |||
| 15C | 2422.0 - 2452.0 | 0.0676 |
| Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application qAf/WO7d9cD0EKULcn/fTg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Axischina Technology Co, Ltd 3rd Floor,No 270,Jieling New Village,Dashuikeng Community,Fucheng Street,Longhua District,Shenzhen Shenzhen, China |
Date of Grant: 10/18/2019 Application Dated: 10/17/2019 |
| Attention: Huang HaoYou |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AT3R-PT311PW2 |
| Name of Grantee: | Shenzhen Axischina Technology Co, Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | WIFI CAM |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.162 | |||
| 15C | 2422.0 - 2452.0 | 0.0676 |
| Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |