FCC ID 2ATC9-PHC-11AC1

PHC-11AC1-A Combined WLAN and Bluetooth Module

by Philips Health Systems

Grantee Code: 2ATC9   Product Code: PHC11AC1
Latest application date: 2023-06-16

FCC ID Device Details

FCC ID2ATC9-PHC-11AC1
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ATC9
Product CodePHC11AC1
Applicant BusinessPhilips Health Systems 🇺🇸
Related Domains philips.com
Equipment ClassPHC-11AC1-A Combined WLAN and Bluetooth Module
Test FirmLaird Connectivity LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2023-06-16
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2023-06-16
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2023-06-16
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2022-02-18
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2022-02-18
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2022-02-18
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/20152021-08-10
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/20152021-08-10
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/20152021-08-10
2402-2480 MHzOriginal Equipment2020-07-21
2402-2480 MHzOriginal Equipment2020-07-21
5180-5240 MHzOriginal Equipment2020-07-21

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2021-01-17PDF 214.9 KB
Internal PhotosInternal Photos2021-01-17PDF 282.7 KB
External PhotosExternal Photos2021-08-10PDF 111.9 KB
External PhotosExternal Photos2021-01-17PDF 389.1 KB
LabelID Label/Location Info2021-08-10PDF 913 KB
Label LocationID Label/Location Info2021-08-10PDF 72.6 KB
ID Label and LocationID Label/Location Info2020-07-21PDF 145.1 KB
Power TableOperational Description2023-06-16PDF 589.5 KB
Antenna Description (1)Operational Description2020-07-21PDF 85.8 KB
Antenna Description (2)Operational Description2020-07-21PDF 325.2 KB
Antenna Description (3)Operational Description2020-07-21PDF 748.2 KB
Antenna Description (4)Operational Description2020-07-21PDF 413.1 KB
Antenna Description (5)Operational Description2020-07-21PDF 2.2 MB
Antenna Description (6)Operational Description2020-07-21PDF 2.1 MB
Antenna Description (7)Operational Description2020-07-21PDF 481.6 KB
SAR Test Set- Up PhotosTest Setup Photos2023-06-16PDF 733.5 KB
EMC Test Set-up PhotosTest Setup Photos2021-01-17PDF 468.8 KB
Test Set- Up PhotosTest Setup Photos2021-01-17PDF 468.8 KB
DFS Test ReportTest Report2020-07-21PDF 941.1 KB
EMC Test ReportTest Report2020-07-21PDF 3 MB
EMC Test Report (1)Test Report2020-07-21PDF 5.5 MB
EMC Test Report (1)Test Report2020-07-21PDF 4.9 MB
EMC Test Report (2)Test Report2020-07-21PDF 4.7 MB
EMC Test Report (2)Test Report2020-07-21PDF 5.5 MB
EMC Test Report (3)Test Report2020-07-21PDF 5.4 MB
EMC Test Report (4)Test Report2020-07-21PDF 1 MB
Covered List AttestationAttestation Statements2023-06-16PDF 345.5 KB
US Agent for SoPAttestation Statements2023-06-16PDF 354 KB
AttestationAttestation Statements2022-02-18PDF 163.3 KB
Application Cover LetterCover Letter(s)2023-06-16PDF 209.4 KB
Cover LetterCover Letter(s)2022-02-18PDF 205.6 KB
Agent Authorization LetterCover Letter(s)2021-08-10PDF 1.5 MB
Change in ID Request LetterCover Letter(s)2021-08-10PDF 1.2 MB
Original Grantee Cover LetterCover Letter(s)2021-08-10PDF 601.9 KB
Authorization LetterCover Letter(s)2020-07-21PDF 568.6 KB
Confidentiality RequestCover Letter(s)2020-07-21PDF 345.6 KB
Cover LetterCover Letter(s)2020-07-21PDF 147.4 KB
Modular Approval ChecklistCover Letter(s)2020-07-21PDF 1.4 MB
RFx not applicableRF Exposure Info2023-06-16PDF 140.4 KB
SAR Report (1)RF Exposure Info2023-06-16PDF 2.4 MB
SAR Report (2)RF Exposure Info2023-06-16PDF 2.8 MB
MPE ReportRF Exposure Info2020-07-21PDF 570.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 633.2 KB
Schematics Metadata onlySchematicsPDF 104.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 547.1 KB

Application Information

Application IDcw8YWKXNqPlvS16tjTCQBQ==
Final Action Date2023-06-16
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0027781111
ModelPHC-11AC1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPHC-11AC1-A Combined WLAN and Bluetooth Module
Responsible PartyMark Nolin, Sr. Network Engineer, mark.nolin@philips.com , 9786592977
Technical ContactMurat Senel, Philips North America LLC, murat.senel@philips.com
Test FirmAdam Alger, Laird Connectivity LLC, adam.alger@lairdconnect.com , 262 375 3091
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change Limited Modular Approval Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures. This device employs 20 MHz and 40 MHz BW modes for 802.11 operation. This c2pc authorizes portable operation in the specific Philips host devices identified in the filing, with the reduced output power level as noted. The highest reported SAR value is 1.44 W/kg. BLE operation is disabled in this c2pc.

Applications

Application IDDatePurpose
cw8YWKXNqPlvS16tjTCQBQ==2023-06-16Class II permissive change or modification of presently authorized equipment
QXaQhcY0R48STs+u/KzA7g==2023-06-16Class II permissive change or modification of presently authorized equipment
6oHLObrtJMFJvA9d5FsCDQ==2023-06-16Class II permissive change or modification of presently authorized equipment
OXA7l5PEQ5PBpfx5py3CEg==2022-02-18Class II permissive change or modification of presently authorized equipment
L0hgUwCJAuvXQgz0auKg4w==2022-02-18Class II permissive change or modification of presently authorized equipment
FENaK/2pxxiykTGodCupEg==2022-02-18Class II permissive change or modification of presently authorized equipment
wZysH8BeAPT7OaQgbe6iVg==2021-08-10Change in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/2015
ChvpKkV6alCbQW/YjuLqdw==2021-08-10Change in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/2015
901Uuxe8+LNkOfnNt0f7mA==2021-08-10Change in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/2015
0tHvcf3K8yNizgMhMiGwww==2021-08-10Change in identification of presently authorized equipment. Original FCC ID: PPD-QCNFA344AH Grant Date: 08/21/2015
lzc8eQlvmRx01Y+Goqzl2g==2020-07-21Original Equipment
g3Ks6cdsu+ANm0H6mE9yPA==2020-07-21Original Equipment
PUIF8ikM21LpVJNNqeKawg==2020-07-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
2402-2480 MHz0.020000015CCC
2402-2480 MHz0.007900015CCC
2402-2480 MHz0.00315CCC
2402-2480 MHz0.003415CCC
2412-2462 MHz0.17815CCC
2412-2472 MHz0.52415CCC, MO
2422-2462 MHz0.48415CCC, MO
5180-5240 MHz0.015915ECC
5190-5230 MHz0.0615E38, CC, MO
5210 MHz0.01415E38, CC, MO
5260-5320 MHz0.021415ECC
5260-5320 MHz0.06615E38, CC, MO
5270-5310 MHz0.05715E38, CC, MO
5290 MHz0.0215E38, CC, MO
5500-5700 MHz0.012315ECC
5500-5720 MHz0.07315E38, CC, MO
5510-5710 MHz0.05415E38, CC, MO
5530-5690 MHz0.04715E38, CC, MO
5745-5825 MHz0.07815E38, CC, MO
5745-5825 MHz0.011815ECC
5775 MHz0.013615E38, CC, MO

Grants

TCB Grant - Application wZysH8BeAPT7OaQgbe6iVg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/10/2021

Application Dated: 08/09/2021
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.072  
38 CC MO 15E 5190.0  -  5230.0 0.06  
38 CC MO 15E 5210.0  -  5210.0 0.014  
38 CC MO 15E 5260.0  -  5320.0 0.066  
38 CC MO 15E 5270.0  -  5310.0 0.057  
38 CC MO 15E 5290.0  -  5290.0 0.02  
38 CC MO 15E 5500.0  -  5720.0 0.073  
38 CC MO 15E 5510.0  -  5710.0 0.054  
38 CC MO 15E 5530.0  -  5690.0 0.047  
38 CC MO 15E 5745.0  -  5825.0 0.078  
38 CC MO 15E 5775.0  -  5775.0 0.0136  

Output power listed is maximum combined conducted. This device supports 20, 40, and 80 MHz bandwidths. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. This device supports client only operating modes in the 5150-5350MHz and 5470-5725MHz bands. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR for body and simultaneous transmission conditions are 0.32 W/kg and 0.32 W/kg respectively.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application wZysH8BeAPT7OaQgbe6iVg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 08/10/2021

Application Dated: 08/09/2021
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.072  
38 CC MO 15E 5190.0  -  5230.0 0.06  
38 CC MO 15E 5210.0  -  5210.0 0.014  
38 CC MO 15E 5260.0  -  5320.0 0.066  
38 CC MO 15E 5270.0  -  5310.0 0.057  
38 CC MO 15E 5290.0  -  5290.0 0.02  
38 CC MO 15E 5500.0  -  5720.0 0.073  
38 CC MO 15E 5510.0  -  5710.0 0.054  
38 CC MO 15E 5530.0  -  5690.0 0.047  
38 CC MO 15E 5745.0  -  5825.0 0.078  
38 CC MO 15E 5775.0  -  5775.0 0.0136  

Output power listed is maximum combined conducted. This device supports 20, 40, and 80 MHz bandwidths. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. This device supports client only operating modes in the 5150-5350MHz and 5470-5725MHz bands. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR for body and simultaneous transmission conditions are 0.32 W/kg and 0.32 W/kg respectively.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application QXaQhcY0R48STs+u/KzA7g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
313 Park Avenue Suite 300
Falls Church, VA 22046
Date of Grant: 06/16/2023

Application Dated: 06/16/2023
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.

This c2pc authorizes portable operation in the specific Philips host devices identified in the filing, with the reduced output power levels as noted. The highest reported SAR value is 1.59 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application QXaQhcY0R48STs+u/KzA7g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 06/16/2023

Application Dated: 06/16/2023
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.

This c2pc authorizes portable operation in the specific Philips host devices identified in the filing, with the reduced output power levels as noted. The highest reported SAR value is 1.59 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application PUIF8ikM21LpVJNNqeKawg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/21/2020

Application Dated: 07/16/2020
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application PUIF8ikM21LpVJNNqeKawg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 07/21/2020

Application Dated: 07/16/2020
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application OXA7l5PEQ5PBpfx5py3CEg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 02/18/2022

Application Dated: 02/18/2022
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application OXA7l5PEQ5PBpfx5py3CEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 02/18/2022

Application Dated: 02/18/2022
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application lzc8eQlvmRx01Y+Goqzl2g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/21/2020

Application Dated: 07/16/2020
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application lzc8eQlvmRx01Y+Goqzl2g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 07/21/2020

Application Dated: 07/16/2020
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application L0hgUwCJAuvXQgz0auKg4w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 02/18/2022

Application Dated: 02/18/2022
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application L0hgUwCJAuvXQgz0auKg4w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 02/18/2022

Application Dated: 02/18/2022
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0159  
CC 15E 5260.0  -  5320.0 0.0214  
CC 15E 5500.0  -  5700.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0118  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz, 40 MHz, and 80 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application g3Ks6cdsu+ANm0H6mE9yPA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/21/2020

Application Dated: 07/16/2020
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application g3Ks6cdsu+ANm0H6mE9yPA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 07/21/2020

Application Dated: 07/16/2020
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in their own host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application FENaK/2pxxiykTGodCupEg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 02/18/2022

Application Dated: 02/18/2022
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application FENaK/2pxxiykTGodCupEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 02/18/2022

Application Dated: 02/18/2022
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies’ host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application cw8YWKXNqPlvS16tjTCQBQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
313 Park Avenue Suite 300
Falls Church, VA 22046
Date of Grant: 06/16/2023

Application Dated: 06/16/2023
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.

This c2pc authorizes portable operation in the specific Philips host devices identified in the filing, with the reduced output power level as noted. The highest reported SAR value is 1.44 W/kg. BLE operation is disabled in this c2pc.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application cw8YWKXNqPlvS16tjTCQBQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 06/16/2023

Application Dated: 06/16/2023
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.178  
CC 15C 2402.0  -  2480.0 0.0034  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

This device employs 20 MHz and 40 MHz BW modes for 802.11 operation.

This c2pc authorizes portable operation in the specific Philips host devices identified in the filing, with the reduced output power level as noted. The highest reported SAR value is 1.44 W/kg. BLE operation is disabled in this c2pc.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application ChvpKkV6alCbQW/YjuLqdw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/10/2021

Application Dated: 08/09/2021
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ChvpKkV6alCbQW/YjuLqdw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 08/10/2021

Application Dated: 08/09/2021
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 901Uuxe8+LNkOfnNt0f7mA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/10/2021

Application Dated: 08/09/2021
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC MO 15C 2412.0  -  2472.0 0.524  
CC MO 15C 2422.0  -  2462.0 0.484  

Output power listed is maximum combined conducted. This device supports 20 and 40MHz bandwidths for 2.4 GHz. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. The antennas used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR for body and simultaneous transmission conditions are 0.77 W/kg and 0.77 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 901Uuxe8+LNkOfnNt0f7mA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 08/10/2021

Application Dated: 08/09/2021
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Digital Transmission System
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC MO 15C 2412.0  -  2472.0 0.524  
CC MO 15C 2422.0  -  2462.0 0.484  

Output power listed is maximum combined conducted. This device supports 20 and 40MHz bandwidths for 2.4 GHz. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. The antennas used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR for body and simultaneous transmission conditions are 0.77 W/kg and 0.77 W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 6oHLObrtJMFJvA9d5FsCDQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
313 Park Avenue Suite 300
Falls Church, VA 22046
Date of Grant: 06/16/2023

Application Dated: 06/16/2023
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

Bluetooth operation is disabled in this c2pc.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 6oHLObrtJMFJvA9d5FsCDQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 06/16/2023

Application Dated: 06/16/2023
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: PHC-11AC1-A Combined WLAN and Bluetooth Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0079  

Class II Permissive Change

Limited Modular Approval

Output power listed is conducted. This device is authorized for use when installed under the control of the grantee in Philips companies host devices. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this device complies with KDB 447498 and is approved for mobile operation. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide operating instructions for complying with FCC multi-transmitter product procedures.

Bluetooth operation is disabled in this c2pc.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 0tHvcf3K8yNizgMhMiGwww==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/10/2021

Application Dated: 08/09/2021
Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.02  

Output power listed is maximum combined conducted. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. The antennas used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR value was < 0.1W/Kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 0tHvcf3K8yNizgMhMiGwww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Philips Health Systems
222 Jacobs St
Cambridge, MA 02141
United States
  Date of Grant: 08/10/2021

Application Dated: 08/09/2021
 
Attention: Mark Nolin , Sr. Network Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATC9-PHC-11AC1
Name of Grantee:  Philips Health Systems
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Rivet Networks 2x2 11ac Wireless Adapter with Bluetooth 4.1, NGFF525A
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.02  

Output power listed is maximum combined conducted. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. Installation in portable devices is limited to the display section of a laptop or notebook PC where the antennas used during SAR testing (or equivalent antennas) are installed to provide at least 1cm distance from the base of the device and with an antenna to antenna separation distance of at least 3cm. The antennas used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. The highest reported SAR value was < 0.1W/Kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: