| FCC ID | 2ATC9-PHC2NET |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ATC9 |
| Product Code | PHC2NET |
| Applicant Business | Philips Health Systems 🇺🇸 |
| Related Domains | |
| Equipment Class | Wireless Data Hub |
| Test Firm | UL Verification Services Inc. (formerly UL CCS) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 | 2020-05-12 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 | 2020-05-12 |
| 699.7-715.3 MHz | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 | 2020-05-12 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 | 2020-05-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Quick Start Guide | Users Manual | 2020-05-12 | PDF 722.1 KB |
| User Manual | Users Manual | 2020-05-12 | PDF 2 MB |
| External Photos | External Photos | 2020-05-12 | PDF 1.1 MB |
| Label | ID Label/Location Info | 2020-05-12 | PDF 231.1 KB |
| Label_Label Location | ID Label/Location Info | 2020-05-12 | PDF 378.1 KB |
| Agent Authorization Letter | Cover Letter(s) | 2020-05-12 | PDF 530.7 KB |
| Change in ID Request Letter | Cover Letter(s) | 2020-05-12 | PDF 207.7 KB |
| Original Grantee Cover Letter | Cover Letter(s) | 2020-05-12 | PDF 89.5 KB |
Application Information
| Application ID | wQ66Dkq1wbmxwZH2axjEuw== |
|---|---|
| Final Action Date | 2020-05-12 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
| Applicant FRN | 0027781111 |
| Model | PHC2NET |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Wireless Data Hub |
| Responsible Party | Mark Nolin, Sr. Network Engineer, mark.nolin@philips.com |
| Test Firm | Jay Kogoma, UL Verification Services Inc. (formerly UL CCS), jay.kogoma@ul.com |
| TCB Email | Soledad.U.Kuwatani@ul.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wQ66Dkq1wbmxwZH2axjEuw== | 2020-05-12 | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
| bUMrb42JEAIWnNNk44ss5Q== | 2020-05-12 | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
| ZjiKGH84pOKr+cy9FDcGKQ== | 2020-05-12 | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
| XHqoprmBLX+CLwKQl2sIXQ== | 2020-05-12 | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
| +JFSjoYI5QtWL1ZN6qTHoA== | 2020-05-12 | Change in identification of presently authorized equipment. Original FCC ID: J9C2NET2LTE Grant Date: 09/26/2017 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 15B | CC | ||||
| 699.7-715.3 MHz | 0.079 | 2.5ppm | 1M09G7W | 27 | |
| 699.7-715.3 MHz | 0.068 | 2.5ppm | 1M08D7W | 27 | |
| 704-711 MHz | 0.075 | 2.5ppm | 8M95G7W | 27 | |
| 704-711 MHz | 0.061 | 2.5ppm | 8M94D7W | 27 | |
| 829-844 MHz | 0.116 | 2.5ppm | 8M97G7W | 22H | |
| 829-844 MHz | 0.09 | 2.5ppm | 8M94D7W | 22H | |
| 1717.5-1747.5 MHz | 0.229 | 2.5ppm | 13M4D7W | 27 | |
| 1720-1745.5 MHz | 0.282 | 2.5ppm | 17M9G7W | 27 | |
| 1720-1745.5 MHz | 0.219 | 2.5ppm | 17M9D7W | 27 | |
| 1857.5-1902.5 MHz | 0.372 | 2.5ppm | 13M4D7W | 24E | |
| 1860-1900 MHz | 0.447 | 2.5ppm | 17M9G7W | 24E | |
| 1860-1900 MHz | 0.363 | 2.5ppm | 17M9D7W | 24E | |
| 2402-2480 MHz | 0.0128800 | 15C | CC | ||
| 2402-2480 MHz | 0.0015 | 15C | CC | ||
| 2412-2462 MHz | 0.1183 | 15C | CC | ||
| 5180-5240 MHz | 0.0426 | 15E | 38, CC | ||
| 5260-5320 MHz | 0.0436 | 15E | 38, CC | ||
| 5500-5720 MHz | 0.0442 | 15E | 38, CC | ||
| 5745-5825 MHz | 0.0458 | 15E | 38, CC |
Grants
TCB Grant - Application ZjiKGH84pOKr+cy9FDcGKQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Philips Health Systems |
| 222 Jacobs St |
| Cambridge, MA 02141 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Wireless Data Hub |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.1365 | 2.5 PM | 4M15F9W | |
| 24E | 1860.0 - 1900.0 | 0.447 | 2.5 PM | 17M9G7W | |
| 24E | 1860.0 - 1900.0 | 0.363 | 2.5 PM | 17M9D7W | |
| 24E | 1857.5 - 1902.5 | 0.372 | 2.5 PM | 13M4D7W | |
| 27 | 1720.0 - 1745.5 | 0.282 | 2.5 PM | 17M9G7W | |
| 27 | 1720.0 - 1745.5 | 0.219 | 2.5 PM | 17M9D7W | |
| 27 | 1717.5 - 1747.5 | 0.229 | 2.5 PM | 13M4D7W | |
| 22H | 829.0 - 844.0 | 0.116 | 2.5 PM | 8M97G7W | |
| 22H | 829.0 - 844.0 | 0.09 | 2.5 PM | 8M94D7W | |
| 27 | 704.0 - 711.0 | 0.075 | 2.5 PM | 8M95G7W | |
| 27 | 704.0 - 711.0 | 0.061 | 2.5 PM | 8M94D7W | |
| 27 | 699.7 - 715.3 | 0.079 | 2.5 PM | 1M09G7W | |
| 27 | 699.7 - 715.3 | 0.068 | 2.5 PM | 1M08D7W |
| This device supports LTE bandwidths of: 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz and 20MHz (LTE B2 1850-1910, LTE B4 1710-1755 MHz); 1.4MHz, 3MHz, 5MHz, 10MHz (LTE B5 824-849 MHz, LTE B12 699-716 MHz). Output power is erp for operations below 1GHz, eirp for operations above 1GHz. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application ZjiKGH84pOKr+cy9FDcGKQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Health Systems 222 Jacobs St Cambridge, MA 02141 United States |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Wireless Data Hub |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.1365 | 2.5 PM | 4M15F9W | |
| 24E | 1860.0 - 1900.0 | 0.447 | 2.5 PM | 17M9G7W | |
| 24E | 1860.0 - 1900.0 | 0.363 | 2.5 PM | 17M9D7W | |
| 24E | 1857.5 - 1902.5 | 0.372 | 2.5 PM | 13M4D7W | |
| 27 | 1720.0 - 1745.5 | 0.282 | 2.5 PM | 17M9G7W | |
| 27 | 1720.0 - 1745.5 | 0.219 | 2.5 PM | 17M9D7W | |
| 27 | 1717.5 - 1747.5 | 0.229 | 2.5 PM | 13M4D7W | |
| 22H | 829.0 - 844.0 | 0.116 | 2.5 PM | 8M97G7W | |
| 22H | 829.0 - 844.0 | 0.09 | 2.5 PM | 8M94D7W | |
| 27 | 704.0 - 711.0 | 0.075 | 2.5 PM | 8M95G7W | |
| 27 | 704.0 - 711.0 | 0.061 | 2.5 PM | 8M94D7W | |
| 27 | 699.7 - 715.3 | 0.079 | 2.5 PM | 1M09G7W | |
| 27 | 699.7 - 715.3 | 0.068 | 2.5 PM | 1M08D7W |
| This device supports LTE bandwidths of: 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz and 20MHz (LTE B2 1850-1910, LTE B4 1710-1755 MHz); 1.4MHz, 3MHz, 5MHz, 10MHz (LTE B5 824-849 MHz, LTE B12 699-716 MHz). Output power is erp for operations below 1GHz, eirp for operations above 1GHz. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Philips Health Systems |
| 222 Jacobs St |
| Cambridge, MA 02141 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Wireless Data Hub |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application XHqoprmBLX+CLwKQl2sIXQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Health Systems 222 Jacobs St Cambridge, MA 02141 United States |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Wireless Data Hub |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Philips Health Systems |
| 222 Jacobs St |
| Cambridge, MA 02141 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Data Hub |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.0426 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.0436 | ||
| 38 CC | 15E | 5500.0 - 5720.0 | 0.0442 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.0458 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application wQ66Dkq1wbmxwZH2axjEuw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Health Systems 222 Jacobs St Cambridge, MA 02141 United States |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Data Hub |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.0426 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.0436 | ||
| 38 CC | 15E | 5500.0 - 5720.0 | 0.0442 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.0458 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Philips Health Systems |
| 222 Jacobs St |
| Cambridge, MA 02141 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Data Hub |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0015 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.1183 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application bUMrb42JEAIWnNNk44ss5Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Health Systems 222 Jacobs St Cambridge, MA 02141 United States |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Data Hub |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0015 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.1183 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Philips Health Systems |
| 222 Jacobs St |
| Cambridge, MA 02141 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless Data Hub |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01288 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application +JFSjoYI5QtWL1ZN6qTHoA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Health Systems 222 Jacobs St Cambridge, MA 02141 United States |
Date of Grant: 05/12/2020 Application Dated: 05/12/2020 |
| Attention: Mark Nolin , Sr. Network Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATC9-PHC2NET |
| Name of Grantee: | Philips Health Systems |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless Data Hub |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01288 |
| Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |