FCC ID 2ATIN-NEN924
Module Intuitiv
by Convectair NMT Inc.
Grantee Code: 2ATIN Product Code: NEN924
Latest application date: 2019-10-14
FCC ID Device Details
| FCC ID | 2ATIN-NEN924 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ATIN |
| Product Code | NEN924 |
| Applicant Business | Convectair NMT Inc. 🇨🇦 |
| Related Domains | |
| Equipment Class | Module Intuitiv |
| Test Firm | Waltek Testing Group (Shenzhen) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2405-2480 MHz | Original Equipment | 2019-10-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2019-10-14 | PDF 232.4 KB |
| internal photos | Internal Photos | 2019-10-14 | PDF 3.5 MB |
| external photos | External Photos | 2019-10-14 | PDF 458.5 KB |
| label&location | ID Label/Location Info | 2019-10-14 | PDF 210.1 KB |
| test setup photos | Test Setup Photos | 2019-10-14 | PDF 1.8 MB |
| test report WIFI | Test Report | 2019-10-14 | PDF 1.9 MB |
| test report zigbee | Test Report | 2019-10-14 | PDF 1.3 MB |
| POA | Cover Letter(s) | 2019-10-14 | PDF 101.4 KB |
| confidentiality request letter | Cover Letter(s) | 2019-10-14 | PDF 116.8 KB |
| RF Exposure | RF Exposure Info | 2019-10-14 | PDF 129.7 KB |
| block diagram Metadata only | Block Diagram | PDF 72.7 KB | |
| schematic diagram Metadata only | Schematics | PDF 949.9 KB | |
| operation description Metadata only | Operational Description | PDF 96.1 KB |
Application Information
| Application ID | QIMdpBlhpf3+GUB7sAkhEQ== |
|---|---|
| Final Action Date | 2019-10-14 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028528156 |
| Model | NEN924 |
| Frequency Range | 2405-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Module Intuitiv |
| Responsible Party | Youri Cupidon, youri.cupidon@convectair.ca |
| Test Firm | Jandy So, Waltek Testing Group (Shenzhen) Co., Ltd., jandyso@semtest.com.cn |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| QIMdpBlhpf3+GUB7sAkhEQ== | 2019-10-14 | Original Equipment |
Grants
TCB Grant - Application QIMdpBlhpf3+GUB7sAkhEQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 10/14/2019 Application Dated: 10/14/2019 |
| Convectair NMT Inc. |
| 30 Carre Sicard |
| Sainte-Therese, J7E3X6 Canada |
| Attention: Youri Cupidon |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATIN-NEN924 |
| Name of Grantee: | Convectair NMT Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Module Intuitiv |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0119 | |||
| 15C | 2405.0 - 2480.0 | 0.0116 |
| Power listed is conducted. Device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application QIMdpBlhpf3+GUB7sAkhEQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Convectair NMT Inc. 30 Carre Sicard Sainte-Therese, J7E3X6 Canada |
Date of Grant: 10/14/2019 Application Dated: 10/14/2019 |
| Attention: Youri Cupidon |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATIN-NEN924 |
| Name of Grantee: | Convectair NMT Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Module Intuitiv |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0119 | |||
| 15C | 2405.0 - 2480.0 | 0.0116 |
| Power listed is conducted. Device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |