FCC ID 2ATO8-INSPIRE

10 INCH TFT Console

by Health In Motion LLC

Grantee Code: 2ATO8   Product Code: INSPIRE
Latest application date: 2019-07-16

FCC ID Device Details

FCC ID2ATO8-INSPIRE
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ATO8
Product CodeINSPIRE
Applicant BusinessHealth In Motion LLC 🇺🇸
Related Domains inspirefitness.net
Equipment Class10 INCH TFT Console
Test FirmShenzhen BALUN Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2019-07-16
2402-2480 MHzOriginal Equipment2019-07-16
2402-2480 MHzOriginal Equipment2019-07-16

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2019-07-16PDF 228.1 KB
internal photosInternal Photos2019-07-16PDF 4.1 MB
external photosExternal Photos2019-07-16PDF 5.3 MB
labelID Label/Location Info2019-07-16PDF 189.4 KB
test setup photosTest Setup Photos2019-07-16PDF 866 KB
NII Test data 1Test Report2019-07-16PDF 2.8 MB
NII Test data 2Test Report2019-07-16PDF 1.4 MB
NII Test data 3Test Report2019-07-16PDF 1.2 MB
test reportTest Report2019-07-16PDF 4.5 MB
test report 2.4G WLANTest Report2019-07-16PDF 3.9 MB
test report 5G WLANTest Report2019-07-16PDF 3.6 MB
test report BLETest Report2019-07-16PDF 2.7 MB
POACover Letter(s)2019-07-16PDF 121.2 KB
confidentiality request letterCover Letter(s)2019-07-16PDF 140.7 KB
RF exposureRF Exposure Info2019-07-16PDF 108.7 KB
block diagram Metadata onlyBlock DiagramPDF 1.2 MB
schematics Metadata onlySchematicsPDF 1.4 MB
operation description Metadata onlyOperational DescriptionPDF 105.6 KB
software security info Metadata onlySDR Software/Security InfPDF 291.6 KB

Application Information

Application IDcPBpIsO+Ms1Z4xP5/sk9nw==
Final Action Date2019-07-16
Application PurposeOriginal Equipment
Applicant FRN0028579167
ModelINSPIRE
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description10 INCH TFT Console
Responsible PartyChris Merli, chris@inspirefitness.net , 7147381729
Test FirmHanson Lin, Shenzhen BALUN Technology Co., Ltd., Hanson.Lin@baluntek.com , 86-755-66833830
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, and 80 MHz bandwidth modes.

Applications

Application IDDatePurpose
cPBpIsO+Ms1Z4xP5/sk9nw==2019-07-16Original Equipment
c5Jchx9Ika6B/531LMJEVw==2019-07-16Original Equipment
LukGcS5QStdmUQEJ+IVI5A==2019-07-16Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.00215CCC
2402-2480 MHz0.006000015CCC
2412-2462 MHz0.02115CCC
5180-5240 MHz0.04615ECC
5745-5825 MHz0.04415ECC

Grants

TCB Grant - Application LukGcS5QStdmUQEJ+IVI5A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 07/16/2019

Application Dated: 07/16/2019
Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: 10 INCH TFT Console
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.006  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application LukGcS5QStdmUQEJ+IVI5A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
United States
  Date of Grant: 07/16/2019

Application Dated: 07/16/2019
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: 10 INCH TFT Console
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.006  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application cPBpIsO+Ms1Z4xP5/sk9nw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 07/16/2019

Application Dated: 07/16/2019
Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 10 INCH TFT Console
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.046  
CC 15E 5745.0  -  5825.0 0.044  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, and 80 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application cPBpIsO+Ms1Z4xP5/sk9nw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
United States
  Date of Grant: 07/16/2019

Application Dated: 07/16/2019
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 10 INCH TFT Console
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.046  
CC 15E 5745.0  -  5825.0 0.044  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, and 80 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application c5Jchx9Ika6B/531LMJEVw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 07/16/2019

Application Dated: 07/16/2019
Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Digital Transmission System
Notes: 10 INCH TFT Console
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  
CC 15C 2412.0  -  2462.0 0.021  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application c5Jchx9Ika6B/531LMJEVw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Health In Motion LLC
255 Airport Circle, Suite 101
Corona, CA 92880
United States
  Date of Grant: 07/16/2019

Application Dated: 07/16/2019
 
Attention: Chris Merli

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATO8-INSPIRE
Name of Grantee:  Health In Motion LLC
Equipment Class: Digital Transmission System
Notes: 10 INCH TFT Console
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  
CC 15C 2412.0  -  2462.0 0.021  

Power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: