FCC ID 2ATVX-YSD008806
SOUNDBAR
by Shen Zhen YU Senda Electronics CO,LTD
Grantee Code: 2ATVX Product Code: YSD008806
Latest application date: 2019-08-01
FCC ID Device Details
| FCC ID | 2ATVX-YSD008806 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2ATVX |
| Product Code | YSD008806 |
| Applicant Business | Shen Zhen YU Senda Electronics CO,LTD 🇨🇳 |
| Equipment Class | SOUNDBAR |
| Test Firm | Shenzhen NTEK Testing Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2019-08-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2020-01-28 | PDF 3.9 MB |
| internal photos | Internal Photos | 2020-01-28 | PDF 747.5 KB |
| external photos | External Photos | 2019-08-01 | PDF 989.6 KB |
| label | ID Label/Location Info | 2019-08-01 | PDF 427.5 KB |
| test setup photos | Test Setup Photos | 2020-01-28 | PDF 337.3 KB |
| test report | Test Report | 2019-08-01 | PDF 4.2 MB |
| SDOC attestation letter | Attestation Statements | 2019-08-01 | PDF 235.5 KB |
| POA | Cover Letter(s) | 2019-08-01 | PDF 26.2 KB |
| confidentiality request letter | Cover Letter(s) | 2019-08-01 | PDF 68.4 KB |
| family model difference declaration | Cover Letter(s) | 2019-08-01 | PDF 64.1 KB |
| MPE | RF Exposure Info | 2019-08-01 | PDF 214.8 KB |
| block diagram Metadata only | Block Diagram | PDF 581.9 KB | |
| schematics Metadata only | Schematics | PDF 714.1 KB | |
| operation description Metadata only | Operational Description | PDF 180.1 KB |
Application Information
| Application ID | FjSni2TvLjjMwKDom1EtBA== |
|---|---|
| Final Action Date | 2019-08-01 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028621290 |
| Model | YSD008806 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | SOUNDBAR |
| Responsible Party | ZEN ZHI PEI, W13480878693@126.com |
| Test Firm | Alex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/28/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| FjSni2TvLjjMwKDom1EtBA== | 2019-08-01 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2402-2480 MHz | 0.0037980 | 15C |
Grants
TCB Grant - Application FjSni2TvLjjMwKDom1EtBA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 08/01/2019 Application Dated: 08/01/2019 |
| Shen Zhen YU Senda Electronics CO,LTD |
| Second floor of three buildings in Fuhai |
| Industrial Zone, Qiaotou Village, Fuyong Town, |
| Bao'an District, Shenzhen, China |
| Attention: ZEN ZHI PEI |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATVX-YSD008806 |
| Name of Grantee: | Shen Zhen YU Senda Electronics CO,LTD |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | SOUNDBAR |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.003798 |
| Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. |
EAS Grant - Application FjSni2TvLjjMwKDom1EtBA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shen Zhen YU Senda Electronics CO,LTD Second floor of three buildings in Fuhai Industrial Zone, Qiaotou Village, Fuyong Town, Bao'an District, Shenzhen, China |
Date of Grant: 08/01/2019 Application Dated: 08/01/2019 |
| Attention: ZEN ZHI PEI |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ATVX-YSD008806 |
| Name of Grantee: | Shen Zhen YU Senda Electronics CO,LTD |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | SOUNDBAR |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.003798 |
| Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. |
| Mail To: |