FCC ID 2ATWZ-V5X2G

Real-time temperature logger

by Shanghai Dewav IoT Technology Co.,Ltd.

Grantee Code: 2ATWZ   Product Code: V5X2G
Latest application date: 2022-07-04

FCC ID Device Details

FCC ID2ATWZ-V5X2G
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ATWZ
Product CodeV5X2G
Applicant BusinessShanghai Dewav IoT Technology Co.,Ltd. 🇨🇳
Related Domains dewav.com
Equipment ClassReal-time temperature logger
Test FirmShenzhen Tongzhou Testing Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2022-07-04

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-07-04PDF 140.5 KB
Internal PhotosInternal Photos2022-07-04PDF 962.2 KB
External PhotosExternal Photos2022-07-04PDF 545 KB
Label&Label LocationID Label/Location Info2022-07-04PDF 284.3 KB
Test Setup PhotosTest Setup Photos2022-07-04PDF 231.8 KB
Test ReportTest Report2022-07-04PDF 1.9 MB
Declaration Letter of Model DifferenceCover Letter(s)2022-07-04PDF 1.4 MB
FCC Confidentiality request letterCover Letter(s)2022-07-04PDF 205.3 KB
FCC POACover Letter(s)2022-07-04PDF 173 KB
Exposure ReportRF Exposure Info2022-07-04PDF 144.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 81.1 KB
Schematic Metadata onlySchematicsPDF 130.4 KB
Declaration concerning Antenna Specification Metadata onlyOperational DescriptionPDF 172.7 KB
Operation description Metadata onlyOperational DescriptionPDF 564.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 198.5 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 315.2 KB

Application Information

Application IDpV12O9kujE4kUpRSSNYZ1g==
Final Action Date2022-07-04
Application PurposeOriginal Equipment
Applicant FRN0008466054
ModelV5X2G
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionReal-time temperature logger
Responsible PartyKevin Zhang, Kevin.zhang@dewav.com , 86 18616682110
Test FirmAndy Zhang, Shenzhen Tongzhou Testing Co., LTD, Andy.Zhang@sztz-testing.com , +86-755-32902198
TCB Emailjoergkusig@eurofins.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP below 1GHz and EIRP above 1GHz. This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
pV12O9kujE4kUpRSSNYZ1g==2022-07-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.45812.5ppm249KGXW22H
1850.2-1909.8 MHz0.29792.5ppm248KGXW24E

Grants

TCB Grant - Application pV12O9kujE4kUpRSSNYZ1g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 07/04/2022

Application Dated: 07/03/2022
Shanghai Dewav IoT Technology Co.,Ltd.
5th Floor,C8-30 of Lane 3188,
Xiupu Road,Pudong New District,
Shanghai,
China
 
Attention: Kevin Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATWZ-V5X2G
Name of Grantee:  Shanghai Dewav IoT Technology Co.,Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Real-time temperature logger
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4581 2.5  PM 249KGXW
24E 1850.2  -  1909.8 0.2979 2.5  PM 248KGXW

Output power listed is ERP below 1GHz and EIRP above 1GHz. This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application pV12O9kujE4kUpRSSNYZ1g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shanghai Dewav IoT Technology Co.,Ltd.
5th Floor,C8-30 of Lane 3188, Xiupu Road,Pudong New District,
Shanghai,
China
  Date of Grant: 07/04/2022

Application Dated: 07/03/2022
 
Attention: Kevin Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATWZ-V5X2G
Name of Grantee:  Shanghai Dewav IoT Technology Co.,Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Real-time temperature logger
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4581 2.5  PM 249KGXW
24E 1850.2  -  1909.8 0.2979 2.5  PM 248KGXW

Output power listed is ERP below 1GHz and EIRP above 1GHz. This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.