FCC ID 2ATXJ-OCTO2020

Telemetry Device

by Danfoss A/S

Grantee Code: 2ATXJ   Product Code: OCTO2020
Latest application date: 2021-05-20

FCC ID Device Details

FCC ID2ATXJ-OCTO2020
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ATXJ
Product CodeOCTO2020
Applicant BusinessDanfoss A/S 🇩🇰
Related Domains danfoss.com
Equipment ClassTelemetry Device
Test FirmUL International Germany GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2021-05-20

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-06-30PDF 2.6 MB
Internal PhotosInternal Photos2021-06-30PDF 319.5 KB
External Photos 1External Photos2021-05-20PDF 615.5 KB
External Photos 2External Photos2021-05-20PDF 618.8 KB
Label DetailID Label/Location Info2021-05-20PDF 146.7 KB
Label PositionID Label/Location Info2021-05-20PDF 273.8 KB
Module DatasheetOperational Description2021-05-20PDF 2.6 MB
Test Set Up BTTest Setup Photos2021-06-30PDF 4.5 MB
Test Set Up WLANTest Setup Photos2021-06-30PDF 4.5 MB
Test Report BTTest Report2021-05-20PDF 1.7 MB
Test Report WLAN Part 1Test Report2021-05-20PDF 3.1 MB
Test Report WLAN Part 2Test Report2021-05-20PDF 3.1 MB
Attestation BT BR DisabledAttestation Statements2021-05-20PDF 45.4 KB
Authorisation LetterCover Letter(s)2021-05-20PDF 50 KB
Confidentiality RequestCover Letter(s)2021-05-20PDF 54.4 KB
ST Confidentiality LetterCover Letter(s)2021-05-20PDF 59.4 KB
MPE CalculationRF Exposure Info2021-05-20PDF 192.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 618.9 KB
Schematics 1 Metadata onlySchematicsPDF 3.2 MB
Schematics 2 Metadata onlySchematicsPDF 85.5 KB
Antenna Info Metadata onlyOperational DescriptionPDF 832 KB
Operational Description Metadata onlyOperational DescriptionPDF 245.7 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 193.7 KB
Tune Up Info Metadata onlyParts List/Tune Up InfoPDF 63.8 KB

Application Information

Application IDwyPcFsZYk2jdv9rUvjpxYQ==
Final Action Date2021-05-20
Application PurposeOriginal Equipment
Applicant FRN0028632388
ModelOCTO2020
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionTelemetry Device
Responsible PartyThomas Krogh Nielsen, Senior Approval Consultant, tni@danfoss.com , 0045 60619160
Technical ContactSaravanan Arumugam, Danfoss A/S, saravanan.arumugam@danfoss.com
Test FirmBernd Woerl, UL International Germany GmbH, bernd.woerl@ul.com , 4971149002031
TCB Emailcertification@ul.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/30/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except as detailed in this filing and in accordance with FCC multi- transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
wyPcFsZYk2jdv9rUvjpxYQ==2021-05-20Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001215C
2412-2462 MHz0.005215C

Grants

TCB Grant - Application wyPcFsZYk2jdv9rUvjpxYQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL International (UK) Ltd
Unit 1-3 Horizon Business Park Wade Road
Basingstoke, RG24 8AH
United Kingdom
Date of Grant: 05/20/2021

Application Dated: 05/20/2021
Danfoss A/S
tni@danfoss.com
Nordborg, 6430
Denmark
 
Attention: Thomas Nielsen , Senior Approval Consultant

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATXJ-OCTO2020
Name of Grantee:  Danfoss A/S
Equipment Class: Digital Transmission System
Notes: Telemetry Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  
15C 2412.0  -  2462.0 0.0052  

Power output is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except as detailed in this filing and in accordance with FCC multi- transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

EAS Grant - Application wyPcFsZYk2jdv9rUvjpxYQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Danfoss A/S
tni@danfoss.com
Nordborg, 6430
Denmark
  Date of Grant: 05/20/2021

Application Dated: 05/20/2021
 
Attention: Thomas Nielsen , Senior Approval Consultant

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ATXJ-OCTO2020
Name of Grantee:  Danfoss A/S
Equipment Class: Digital Transmission System
Notes: Telemetry Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  
15C 2412.0  -  2462.0 0.0052  

Power output is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except as detailed in this filing and in accordance with FCC multi- transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.



Mail To: