FCC ID 2AU5DWZ3TSTAT

Thermostat

by Legrand/Pass & Seymour

Grantee Code: 2AU5D   Product Code: WZ3TSTAT
Latest application date: 2021-06-29

FCC ID Device Details

FCC ID2AU5DWZ3TSTAT
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AU5D
Product CodeWZ3TSTAT
Applicant BusinessLegrand/Pass & Seymour 🇺🇸
Related Domains legrand.us
Equipment ClassThermostat
Test FirmGlobal United Technology Services Co. Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2021-06-29
2405-2480 MHzOriginal Equipment2021-06-29
2402-2480 MHzOriginal Equipment2021-06-29

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-06-29PDF 4.1 MB
User Manual1Users Manual2021-06-29PDF 3.5 MB
User Manual2Users Manual2021-06-29PDF 4.1 MB
Internal PhotosInternal Photos2021-06-29PDF 1.4 MB
External PhotosExternal Photos2021-06-29PDF 261.1 KB
LABELID Label/Location Info2021-06-29PDF 648.6 KB
Labe LocationID Label/Location Info2021-06-29PDF 648.6 KB
Setup photosTest Setup Photos2021-06-29PDF 146.6 KB
Test Setup photosTest Setup Photos2021-06-29PDF 146.6 KB
Test setup photoTest Setup Photos2021-06-29PDF 146.6 KB
Blcok diagram Metadata onlyTest Report2021-06-29PDF 226.3 KB
RFExposure Metadata onlyTest Report2021-06-29PDF 202.9 KB
Test ReporTest Report2021-06-29PDF 5.8 MB
Test ReportTest Report2021-06-29PDF 1.8 MB
Test ReportTest Report2021-06-29PDF 5.8 MB
Test ReportTest Report2021-06-29PDF 5.9 MB
Agent Authorization Rev 1.0Cover Letter(s)2021-06-29PDF 20.9 KB
FCC Agent AuthorizationCover Letter(s)2021-06-29PDF 20.9 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2021-06-29PDF 110.1 KB
FCC Software Configuration Control DeclarationCover Letter(s)2021-06-29PDF 87.7 KB
RF ExposureRF Exposure Info2021-06-29PDF 202.9 KB
RF exposureRF Exposure Info2021-06-29PDF 202.9 KB
Block diagram Metadata onlyBlock DiagramPDF 226.3 KB
BlockDiagram Metadata onlyBlock DiagramPDF 226.3 KB
SCH Metadata onlySchematicsPDF 337.5 KB
OP Metadata onlyOperational DescriptionPDF 311.2 KB
Operation description Metadata onlyOperational DescriptionPDF 311.2 KB
FCC Software Security Requirements for UNII devices Rev 2 Metadata onlySDR Software/Security InfPDF 66.4 KB

Application Information

Application IDznhXapGOX+SfVbVdWlaAiA==
Final Action Date2021-06-29
Application PurposeOriginal Equipment
Applicant FRN0028978146
ModelWZ3TSTAT
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionThermostat
Responsible PartyKris Glassford, Testing Lab & Certification Manager, kris.glassford@legrand.us , 3154688014
Technical ContactLegrand/Pass & Seymour, kris.glassford@legrand.us
Test FirmRobinson Lo, Global United Technology Services Co. Ltd., robinson.lo@gtstest.com , 86-0-755-2779-8480
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. This device contains 20, 40 and 80 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
znhXapGOX+SfVbVdWlaAiA==2021-06-29Original Equipment
aJlQ7h1ex/VkA5+3S5LaCg==2021-06-29Original Equipment
DyaFupDsqRtShPMwzn8Rpw==2021-06-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz15CCC
2405-2480 MHz0.0510515CCC
2412-2462 MHz0.051415CCC, MO
5180-5240 MHz0.0365615E38, CC, MO
5260-5320 MHz0.037515E38, CC, MO, ND
5500-5700 MHz0.0286415E38, CC, MO, ND
5745-5825 MHz0.0271615E38, CC, MO

Grants

TCB Grant - Application znhXapGOX+SfVbVdWlaAiA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2021

Application Dated: 06/29/2021
Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Thermostat
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.03656  
38 CC MO ND 15E 5500.0  -  5700.0 0.02864  
38 CC MO ND 15E 5260.0  -  5320.0 0.0375  
38 CC MO 15E 5745.0  -  5825.0 0.02716  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. This device contains 20, 40 and 80 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application znhXapGOX+SfVbVdWlaAiA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
United States
  Date of Grant: 06/29/2021

Application Dated: 06/29/2021
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Thermostat
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.03656  
38 CC MO ND 15E 5500.0  -  5700.0 0.02864  
38 CC MO ND 15E 5260.0  -  5320.0 0.0375  
38 CC MO 15E 5745.0  -  5825.0 0.02716  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. This device contains 20, 40 and 80 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application DyaFupDsqRtShPMwzn8Rpw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2021

Application Dated: 06/29/2021
Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Thermostat
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application DyaFupDsqRtShPMwzn8Rpw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
United States
  Date of Grant: 06/29/2021

Application Dated: 06/29/2021
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Thermostat
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application aJlQ7h1ex/VkA5+3S5LaCg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2021

Application Dated: 06/29/2021
Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Digital Transmission System
Notes: Thermostat
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2480.0 0.05105  
CC MO 15C 2412.0  -  2462.0 0.0514  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application aJlQ7h1ex/VkA5+3S5LaCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Legrand/Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
United States
  Date of Grant: 06/29/2021

Application Dated: 06/29/2021
 
Attention: Kris Glassford , Testing Lab & Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU5DWZ3TSTAT
Name of Grantee:  Legrand/Pass & Seymour
Equipment Class: Digital Transmission System
Notes: Thermostat
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2405.0  -  2480.0 0.05105  
CC MO 15C 2412.0  -  2462.0 0.0514  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: