FCC ID 2AU97NET

Mobile Phone

by Shenzhen Krono Digital Co., Ltd.

Grantee Code: 2AU97   Product Code: NET
Latest application date: 2021-12-22

FCC ID Device Details

FCC ID2AU97NET
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AU97
Product CodeNET
Applicant BusinessShenzhen Krono Digital Co., Ltd. 🇨🇳
Equipment ClassMobile Phone
Test FirmSHENZHEN TONGCE TESTING LAB

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2021-12-22
824.2-848.8 MHzOriginal Equipment2021-12-22

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2021-12-22PDF 3 MB
Int photoInternal Photos2021-12-22PDF 1,022.4 KB
Ext photoExternal Photos2021-12-22PDF 812.2 KB
labelID Label/Location Info2021-12-22PDF 170.9 KB
Test photoTest Setup Photos2021-12-22PDF 221.9 KB
test photoTest Setup Photos2021-12-22PDF 153.5 KB
Test reportTest Report2021-12-22PDF 5.4 MB
test reportTest Report2021-12-22PDF 1.4 MB
sDoC Attestation letterCover Letter(s)2021-12-22PDF 114.2 KB
Agent AuthorizationCover Letter(s)2021-12-22PDF 86 KB
FCC long Term Only ConfidentialityCover Letter(s)2021-12-22PDF 81.3 KB
Model Declaration LetterCover Letter(s)2021-12-22PDF 100.8 KB
RF exposureRF Exposure Info2021-12-22PDF 413.2 KB
SAR reportRF Exposure Info2021-12-22PDF 5.6 MB
Block Metadata onlyBlock DiagramPDF 37 KB
SCH Metadata onlySchematicsPDF 710.8 KB
OP Metadata onlyOperational DescriptionPDF 864.5 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 72 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 64.8 KB

Application Information

Application IDedTnFvsJQ4flONHkWtuR3A==
Final Action Date2021-12-22
Application PurposeOriginal Equipment
Applicant FRN0029020641
ModelNET
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMobile Phone
Responsible PartyAlejandro Cucunuba, General Manager, ququnuba@hotmail.com , +573106802536
Technical ContactShenzhen Krono Digital Co., Ltd., ququnuba@hotmail.com
Test FirmBeryl Zhao, SHENZHEN TONGCE TESTING LAB, berylzhao@tct-lab.com , +8675527208735
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power.

Applications

Application IDDatePurpose
edTnFvsJQ4flONHkWtuR3A==2021-12-22Original Equipment
a+4tTTHmcG/0N0lo4aQ4vg==2021-12-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.940.02ppm245KGXW22H
1850.2-1909.8 MHz0.80.025ppm245KGXW24E
2402-2480 MHz0.005200015C

Grants

TCB Grant - Application edTnFvsJQ4flONHkWtuR3A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 12/22/2021

Application Dated: 12/22/2021
Shenzhen Krono Digital Co., Ltd.
1319, 13th Floor, SegPlaza, Huaqiangbei,
Futian District, Shenzhen, Guangdong, China
Shenzhen,
China
 
Attention: Alejandro Cucunuba , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU97NET
Name of Grantee:  Shenzhen Krono Digital Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0052  

Output power listed is conducted power.

EAS Grant - Application edTnFvsJQ4flONHkWtuR3A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Krono Digital Co., Ltd.
1319, 13th Floor, SegPlaza, Huaqiangbei, Futian District, Shenzhen, Guangdong, China
Shenzhen,
China
  Date of Grant: 12/22/2021

Application Dated: 12/22/2021
 
Attention: Alejandro Cucunuba , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU97NET
Name of Grantee:  Shenzhen Krono Digital Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0052  

Output power listed is conducted power.



TCB Grant - Application a+4tTTHmcG/0N0lo4aQ4vg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 12/22/2021

Application Dated: 12/22/2021
Shenzhen Krono Digital Co., Ltd.
1319, 13th Floor, SegPlaza, Huaqiangbei,
Futian District, Shenzhen, Guangdong, China
Shenzhen,
China
 
Attention: Alejandro Cucunuba , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU97NET
Name of Grantee:  Shenzhen Krono Digital Co., Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.94 0.02  PM 245KGXW
24E 1850.2  -  1909.8 0.8 0.025  PM 245KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head and body-worn accessory use conditions is 0.57W/kg and 0.70W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

EAS Grant - Application a+4tTTHmcG/0N0lo4aQ4vg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Krono Digital Co., Ltd.
1319, 13th Floor, SegPlaza, Huaqiangbei, Futian District, Shenzhen, Guangdong, China
Shenzhen,
China
  Date of Grant: 12/22/2021

Application Dated: 12/22/2021
 
Attention: Alejandro Cucunuba , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AU97NET
Name of Grantee:  Shenzhen Krono Digital Co., Ltd.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.94 0.02  PM 245KGXW
24E 1850.2  -  1909.8 0.8 0.025  PM 245KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head and body-worn accessory use conditions is 0.57W/kg and 0.70W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



Mail To: