FCC ID 2AUARTHINKDIAG3

Multifunctional Diagnostic Box

by THINKCAR TECH CO., LTD.

Grantee Code: 2AUAR   Product Code: THINKDIAG3
Latest application date: 2023-06-02

FCC ID Device Details

FCC ID2AUARTHINKDIAG3
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUAR
Product CodeTHINKDIAG3
Applicant BusinessTHINKCAR TECH CO., LTD. 🇨🇳
Related Domains mythinkcar.com
Equipment ClassMultifunctional Diagnostic Box
Test FirmShenzhen ZKT Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-06-02
2402-2480 MHzOriginal Equipment2023-06-02
5745-5825 MHzOriginal Equipment2023-06-02

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2023-11-28PDF 4.9 MB
user manualUsers Manual2023-11-28PDF 4.9 MB
user manual-1Users Manual2023-11-28PDF 4.9 MB
user manual-2Users Manual2023-11-28PDF 4.4 MB
user manual-3Users Manual2023-11-28PDF 2.7 MB
internal photoInternal Photos2023-11-28PDF 1.1 MB
internalPhotoInternal Photos2023-11-28PDF 1.1 MB
External photoExternal Photos2023-11-28PDF 480 KB
ExternalPhotoExternal Photos2023-11-28PDF 480 KB
external photoExternal Photos2023-11-28PDF 480 KB
label and label locationID Label/Location Info2023-06-02PDF 60.6 KB
label and locationID Label/Location Info2023-06-02PDF 60.6 KB
ANT reportBlock Diagram2023-06-02PDF 207.2 KB
test photoTest Setup Photos2023-11-28PDF 205.3 KB
test reportTest Report2023-06-02PDF 3.1 MB
test reportTest Report2023-06-02PDF 4.2 MB
test reportTest Report2023-06-02PDF 2.3 MB
USA agentAttestation Statements2023-06-02PDF 79.2 KB
cover letterAttestation Statements2023-06-02PDF 63.3 KB
ANT ReportCover Letter(s)2023-06-02PDF 207.2 KB
ANT reportCover Letter(s)2023-06-02PDF 214.3 KB
ANT report-1Cover Letter(s)2023-06-02PDF 214.3 KB
ANT report-2Cover Letter(s)2023-06-02PDF 207.2 KB
AgentAuthorizationLetterTemplateCover Letter(s)2023-06-02PDF 50.1 KB
FCC Short &Long Term Confidentiality RequestCover Letter(s)2023-06-02PDF 26.2 KB
FCC Software Configuration Control DeclarationCover Letter(s)2023-06-02PDF 46 KB
Family models letterCover Letter(s)2023-06-02PDF 17.8 KB
family models letterCover Letter(s)2023-06-02PDF 17.8 KB
RF exposure reportRF Exposure Info2023-06-02PDF 5.2 MB
SAR reportRF Exposure Info2023-06-02PDF 5.2 MB
BLOCK Metadata onlyBlock DiagramPDF 186.4 KB
SCH Metadata onlySchematicsPDF 1.2 MB
OPS Metadata onlyOperational DescriptionPDF 144.3 KB
Software Security Requirements for UNII devices Metadata onlySDR Software/Security InfPDF 101.3 KB

Application Information

Application IDxovvA8/oc0wSSjABOBBcLw==
Final Action Date2023-06-02
Application PurposeOriginal Equipment
Applicant FRN0028727014
ModelTHINKDIAG3
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionMultifunctional Diagnostic Box
Responsible PartyJinyuan Tang, Manager, tang@mythinkcar.com , 86-0755-23760920
Technical ContactTHINKCAR TECH CO., LTD., tang@mythinkcar.com
Test FirmLake Xie, Shenzhen ZKT Technology Co., Ltd., zkt@zkt-lab.com , 0086-13620010775
TCB Emailpsingh@qai.org
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/28/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.76W/kg and 0.93W/kg respectively.

Applications

Application IDDatePurpose
xovvA8/oc0wSSjABOBBcLw==2023-06-02Original Equipment
vW3xulf2MfFDlNR9LSRX7w==2023-06-02Original Equipment
lfkv/kKCXg7JLdVQoWRbtg==2023-06-02Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.002390015CCC
2402-2480 MHz0.0065615CCC
2412-2462 MHz0.115CCC
5745-5825 MHz0.002300015ECC

Grants

TCB Grant - Application xovvA8/oc0wSSjABOBBcLw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 06/02/2023

Application Dated: 06/01/2023
THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou
community, Bantian, Longgang District
Shenzhen,
China
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Digital Transmission System
Notes: Multifunctional Diagnostic Box
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00656  
CC 15C 2412.0  -  2462.0 0.1  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.76W/kg and 0.93W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application xovvA8/oc0wSSjABOBBcLw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District
Shenzhen,
China
  Date of Grant: 06/02/2023

Application Dated: 06/01/2023
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Digital Transmission System
Notes: Multifunctional Diagnostic Box
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00656  
CC 15C 2412.0  -  2462.0 0.1  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.76W/kg and 0.93W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application vW3xulf2MfFDlNR9LSRX7w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 06/02/2023

Application Dated: 06/01/2023
THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou
community, Bantian, Longgang District
Shenzhen,
China
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Multifunctional Diagnostic Box
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00239  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.12W/kg and 0.93W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application vW3xulf2MfFDlNR9LSRX7w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District
Shenzhen,
China
  Date of Grant: 06/02/2023

Application Dated: 06/01/2023
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Multifunctional Diagnostic Box
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00239  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.12W/kg and 0.93W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application lfkv/kKCXg7JLdVQoWRbtg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 06/02/2023

Application Dated: 06/01/2023
THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou
community, Bantian, Longgang District
Shenzhen,
China
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Multifunctional Diagnostic Box
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5745.0  -  5825.0 0.0023  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.22W/kg and 0.93W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application lfkv/kKCXg7JLdVQoWRbtg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

THINKCAR TECH CO., LTD.
2606, building 4, phase II, TiananYungu, Gangtou community, Bantian, Longgang District
Shenzhen,
China
  Date of Grant: 06/02/2023

Application Dated: 06/01/2023
 
Attention: Jinyuan Tang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUARTHINKDIAG3
Name of Grantee:  THINKCAR TECH CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Multifunctional Diagnostic Box
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5745.0  -  5825.0 0.0023  

Output power listed is conducted power.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.22W/kg and 0.93W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: