FCC ID 2AUBA-VC19VTLS09081
Vitals360 Multi-vitals Mobile Monitor
by VoCare Inc
Grantee Code: 2AUBA Product Code: VC19VTLS09081
Latest application date: 2019-11-26
FCC ID Device Details
| FCC ID | 2AUBA-VC19VTLS09081 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AUBA |
| Product Code | VC19VTLS09081 |
| Applicant Business | VoCare Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | Vitals360 Multi-vitals Mobile Monitor |
| Test Firm | Shenzhen UnionTrust Quality and Technology Co., Lt |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2019-11-26 |
| 2402-2480 MHz | Original Equipment | 2019-11-26 |
| 704-711 MHz | Original Equipment | 2019-11-26 |
| 2402-2480 MHz | Original Equipment | 2019-11-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User-Manual | Users Manual | 2019-11-26 | PDF 4.9 MB |
| User_Manual | Users Manual | 2019-11-26 | PDF 3.9 MB |
| User_manual | Users Manual | 2019-11-26 | PDF 4.9 MB |
| Internal_Photos | Internal Photos | 2019-11-26 | PDF 4.1 MB |
| Internal_photos | Internal Photos | 2019-11-26 | PDF 4.1 MB |
| External_Photos | External Photos | 2019-11-26 | PDF 3.2 MB |
| External_photos | External Photos | 2019-11-26 | PDF 3.2 MB |
| Label | ID Label/Location Info | 2019-11-26 | PDF 339.5 KB |
| Label_Location | ID Label/Location Info | 2019-11-26 | PDF 215.9 KB |
| label | ID Label/Location Info | 2019-11-26 | PDF 339.5 KB |
| label_location | ID Label/Location Info | 2019-11-26 | PDF 215.9 KB |
| Test_Setup_Photos | Test Setup Photos | 2019-11-26 | PDF 823.1 KB |
| Test_Setup_Photos | Test Setup Photos | 2019-11-26 | PDF 580 KB |
| FCC Part 15.247 BLE Report | Test Report | 2019-11-26 | PDF 3.9 MB |
| FCC Part 15.247 EDR Report | Test Report | 2019-11-26 | PDF 4.5 MB |
| FCC Part 15.247 Wi-Fi 11Channel Report | Test Report | 2019-11-26 | PDF 2.4 MB |
| FCC Part 15.407 | Test Report | 2019-11-26 | PDF 2.6 MB |
| FCC Part 22&24&27&90 Report | Test Report | 2019-11-26 | PDF 5.2 MB |
| FCC_Part_222427_Report_3G_Report | Test Report | 2019-11-26 | PDF 4.9 MB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2019-11-26 | PDF 1.9 MB |
| Agent_Authorization | Cover Letter(s) | 2019-11-26 | PDF 1.9 MB |
| FCC Software Configuration Control Declaration | Cover Letter(s) | 2019-11-26 | PDF 2.9 MB |
| FCC_Long_Term_Confidentiality_Request_Rev4.1 | Cover Letter(s) | 2019-11-26 | PDF 389 KB |
| FCC_Long_Term_Only_Confidentiality | Cover Letter(s) | 2019-11-26 | PDF 389 KB |
| FCC_Short Long_Term_Confidentiality_Request | Cover Letter(s) | 2019-11-26 | PDF 389 KB |
| 190803004SAR-1_FCC SAR | RF Exposure Info | 2019-11-26 | PDF 5 MB |
| Block_Diagram Metadata only | Block Diagram | PDF 154.4 KB | |
| SCH Metadata only | Schematics | PDF 380.8 KB | |
| Schematic Metadata only | Schematics | PDF 380.8 KB | |
| schematics Metadata only | Schematics | PDF 380.8 KB | |
| Operation_Description Metadata only | Operational Description | PDF 234.7 KB | |
| Operational-Description Metadata only | Operational Description | PDF 234.7 KB | |
| operation_description Metadata only | Operational Description | PDF 234.7 KB | |
| SOFTWARE_SECURITY_REQUIREMENTS Metadata only | SDR Software/Security Inf | PDF 1.6 MB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 399.2 KB | |
| Tune up Info Metadata only | Parts List/Tune Up Info | PDF 216.4 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 216.4 KB | |
| Tune up procedure v1.0 Metadata only | Parts List/Tune Up Info | PDF 216.4 KB | |
| Tune_up_procedure Metadata only | Parts List/Tune Up Info | PDF 216.4 KB |
Application Information
| Application ID | wjTMOxzMhc+ZYyxfAGzJKg== |
|---|---|
| Final Action Date | 2019-11-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028730224 |
| Model | VC19VTLS09081 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Vitals360 Multi-vitals Mobile Monitor |
| Responsible Party | Steven R Peabody, CEO, speabody@vocare.com |
| Technical Contact | VoCare Inc, speabody@vocare.com |
| Test Firm | George Luo, Shenzhen UnionTrust Quality and Technology Co., Lt, quality@uttlab.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specificconfigurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wjTMOxzMhc+ZYyxfAGzJKg== | 2019-11-26 | Original Equipment |
| rRVu63CbEm7cYKGMaDtQ0w== | 2019-11-26 | Original Equipment |
| r2pw9uY6TtTWgdNXNeVKzA== | 2019-11-26 | Original Equipment |
| 75WRc+DmLtbD2ijE7Zi7Og== | 2019-11-26 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 704-711 MHz | 0.11376 | 0.024ppm | 9M01W7D | 27 | |
| 704-711 MHz | 0.08995 | 0.024ppm | 9M01G7D | 27 | |
| 709-711 MHz | 0.12106 | 0.0122ppm | 9M01G7D | 27 | |
| 709-711 MHz | 0.09727 | 0.0122ppm | 9M01W7D | 27 | |
| 779.5-784.5 MHz | 0.11995 | 0.0281ppm | 4M52G7D | 27 | |
| 779.5-784.5 MHz | 0.09638 | 0.0281ppm | 4M51W7D | 27 | |
| 782 MHz | 0.11376 | 0.0281ppm | 8M95G7D | 27 | |
| 782 MHz | 0.09638 | 0.0281ppm | 8M96W7D | 27 | |
| 824.7-848.3 MHz | 0.10839 | 0.0323ppm | 1M10G7D | 22H | |
| 824.7-848.3 MHz | 0.10568 | 0.0323ppm | 1M10W7D | 22H | |
| 829-844 MHz | 0.1122 | 0.0323ppm | 8M97W7D | 22H | |
| 829-844 MHz | 0.0867 | 0.0323ppm | 9M01G7D | 22H | |
| 1712.4-1752.6 MHz | 0.37325 | 0.0139ppm | 4M17F9W | 27 | |
| 1720-1745 MHz | 0.36141 | 0.0144ppm | 18M1G7D | 27 | |
| 1720-1745 MHz | 0.2904 | 0.0144ppm | 17M9W7D | 27 | |
| 1852.4-1907.6 MHz | 0.35892 | 0.0133ppm | 4M18F9W | 24E | |
| 1860-1900 MHz | 0.37411 | 0.0138ppm | 18M1G7D | 24E | |
| 1860-1900 MHz | 0.30409 | 0.0138ppm | 18M0W7D | 24E | |
| 2402-2480 MHz | 0.00116 | 15C | CC | ||
| 2402-2480 MHz | 0.0086100 | 15C | CC | ||
| 2412-2462 MHz | 0.12474 | 15C | CC | ||
| 5180-5240 MHz | 0.02649 | 15E | 38, CC | ||
| 5260-5320 MHz | 0.01977 | 15E | 38, CC | ||
| 5745-5825 MHz | 0.02649 | 15E | 38, CC |
Grants
TCB Grant - Application wjTMOxzMhc+ZYyxfAGzJKg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| VoCare Inc |
| 4950 Turkey Foot Road, |
| Zionsville Indiana 46077, USA |
| Indiana, IN 46077 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.02649 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.01977 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.02649 |
| Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specificconfigurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application wjTMOxzMhc+ZYyxfAGzJKg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
VoCare Inc 4950 Turkey Foot Road, Zionsville Indiana 46077, USA Indiana, IN 46077 United States |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.02649 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.01977 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.02649 |
| Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specificconfigurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| VoCare Inc |
| 4950 Turkey Foot Road, |
| Zionsville Indiana 46077, USA |
| Indiana, IN 46077 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00861 |
| Power listed is the maximum conducted output power. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application rRVu63CbEm7cYKGMaDtQ0w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
VoCare Inc 4950 Turkey Foot Road, Zionsville Indiana 46077, USA Indiana, IN 46077 United States |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00861 |
| Power listed is the maximum conducted output power. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| VoCare Inc |
| 4950 Turkey Foot Road, |
| Zionsville Indiana 46077, USA |
| Indiana, IN 46077 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.18621 | 0.0311 PM | 4M15F9W | |
| 22H | 824.7 - 848.3 | 0.10839 | 0.0323 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.10568 | 0.0323 PM | 1M10W7D | |
| 22H | 829.0 - 844.0 | 0.1122 | 0.0323 PM | 8M97W7D | |
| 22H | 829.0 - 844.0 | 0.0867 | 0.0323 PM | 9M01G7D | |
| 24E | 1852.4 - 1907.6 | 0.35892 | 0.0133 PM | 4M18F9W | |
| 24E | 1860.0 - 1900.0 | 0.37411 | 0.0138 PM | 18M1G7D | |
| 24E | 1860.0 - 1900.0 | 0.30409 | 0.0138 PM | 18M0W7D | |
| 27 | 1712.4 - 1752.6 | 0.37325 | 0.0139 PM | 4M17F9W | |
| 27 | 1720.0 - 1745.0 | 0.36141 | 0.0144 PM | 18M1G7D | |
| 27 | 1720.0 - 1745.0 | 0.2904 | 0.0144 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.11376 | 0.024 PM | 9M01W7D | |
| 27 | 704.0 - 711.0 | 0.08995 | 0.024 PM | 9M01G7D | |
| 27 | 779.5 - 784.5 | 0.11995 | 0.0281 PM | 4M52G7D | |
| 27 | 779.5 - 784.5 | 0.09638 | 0.0281 PM | 4M51W7D | |
| 27 | 782.0 - 782.0 | 0.11376 | 0.0281 PM | 8M95G7D | |
| 27 | 782.0 - 782.0 | 0.09638 | 0.0281 PM | 8M96W7D | |
| 27 | 709.0 - 711.0 | 0.12106 | 0.0122 PM | 9M01G7D | |
| 27 | 709.0 - 711.0 | 0.09727 | 0.0122 PM | 9M01W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
EAS Grant - Application r2pw9uY6TtTWgdNXNeVKzA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
VoCare Inc 4950 Turkey Foot Road, Zionsville Indiana 46077, USA Indiana, IN 46077 United States |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.18621 | 0.0311 PM | 4M15F9W | |
| 22H | 824.7 - 848.3 | 0.10839 | 0.0323 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.10568 | 0.0323 PM | 1M10W7D | |
| 22H | 829.0 - 844.0 | 0.1122 | 0.0323 PM | 8M97W7D | |
| 22H | 829.0 - 844.0 | 0.0867 | 0.0323 PM | 9M01G7D | |
| 24E | 1852.4 - 1907.6 | 0.35892 | 0.0133 PM | 4M18F9W | |
| 24E | 1860.0 - 1900.0 | 0.37411 | 0.0138 PM | 18M1G7D | |
| 24E | 1860.0 - 1900.0 | 0.30409 | 0.0138 PM | 18M0W7D | |
| 27 | 1712.4 - 1752.6 | 0.37325 | 0.0139 PM | 4M17F9W | |
| 27 | 1720.0 - 1745.0 | 0.36141 | 0.0144 PM | 18M1G7D | |
| 27 | 1720.0 - 1745.0 | 0.2904 | 0.0144 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.11376 | 0.024 PM | 9M01W7D | |
| 27 | 704.0 - 711.0 | 0.08995 | 0.024 PM | 9M01G7D | |
| 27 | 779.5 - 784.5 | 0.11995 | 0.0281 PM | 4M52G7D | |
| 27 | 779.5 - 784.5 | 0.09638 | 0.0281 PM | 4M51W7D | |
| 27 | 782.0 - 782.0 | 0.11376 | 0.0281 PM | 8M95G7D | |
| 27 | 782.0 - 782.0 | 0.09638 | 0.0281 PM | 8M96W7D | |
| 27 | 709.0 - 711.0 | 0.12106 | 0.0122 PM | 9M01G7D | |
| 27 | 709.0 - 711.0 | 0.09727 | 0.0122 PM | 9M01W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| VoCare Inc |
| 4950 Turkey Foot Road, |
| Zionsville Indiana 46077, USA |
| Indiana, IN 46077 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00116 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.12474 |
| Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 75WRc+DmLtbD2ijE7Zi7Og==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
VoCare Inc 4950 Turkey Foot Road, Zionsville Indiana 46077, USA Indiana, IN 46077 United States |
Date of Grant: 11/26/2019 Application Dated: 11/26/2019 |
| Attention: Steven Peabody , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AUBA-VC19VTLS09081 |
| Name of Grantee: | VoCare Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | Vitals360 Multi-vitals Mobile Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00116 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.12474 |
| Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 1.10 W/kg and 1.45 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |