FCC ID 2AUES-SAGIA630

Smart Phone

by SAGI MOBILE. S.A.S

Grantee Code: 2AUES   Product Code: SAGIA630
Latest application date: 2019-12-10

FCC ID Device Details

FCC ID2AUES-SAGIA630
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUES
Product CodeSAGIA630
Applicant BusinessSAGI MOBILE. S.A.S 🇨🇴
Related Domains sagi.com.co
Equipment ClassSmart Phone
Test FirmBay Area Compliance Laboratories Corp.(Dongguan)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-12-10
824.2-848.8 MHzOriginal Equipment2019-12-10
2402-2480 MHzOriginal Equipment2019-12-10

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2019-12-10PDF 257.1 KB
Int PhotosInternal Photos2019-12-10PDF 858.9 KB
Ext PhotosExternal Photos2019-12-10PDF 508.9 KB
FCC ID LabelID Label/Location Info2019-12-10PDF 272.2 KB
Setup PhotosTest Setup Photos2019-12-10PDF 239.1 KB
Setup PhotosTest Setup Photos2019-12-10PDF 239.1 KB
Test ReportTest Report2019-12-10PDF 978.8 KB
Test ReportTest Report2019-12-10PDF 990.3 KB
Test ReportTest Report2019-12-10PDF 866.4 KB
Attestation LetterAttestation Statements2019-12-10PDF 83.4 KB
Confidentiality LetterCover Letter(s)2019-12-10PDF 85.7 KB
POACover Letter(s)2019-12-10PDF 110.7 KB
SAR ReportRF Exposure Info2019-12-10PDF 911.3 KB
SAR Report Appendix 1RF Exposure Info2019-12-10PDF 3.1 MB
SAR Report Appendix 2RF Exposure Info2019-12-10PDF 1.1 MB
SAR Report Appendix 3RF Exposure Info2019-12-10PDF 1.9 MB
Block Diagram Metadata onlyBlock DiagramPDF 13.9 KB
Schematics Metadata onlySchematicsPDF 353.8 KB
Operation Description Metadata onlyOperational DescriptionPDF 99.1 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 49.8 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 626.9 KB

Application Information

Application IDbNz+bVvK5BFVGhhFBX+0IA==
Final Action Date2019-12-10
Application PurposeOriginal Equipment
Applicant FRN0028756385
ModelSAGIA630
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Phone
Responsible PartyJUAN ALVARO SALAZAR RAMIREZ, CEO, CEO@SAGI.COM.CO , 57 311 8532981
Test FirmDavid Zhang, Bay Area Compliance Laboratories Corp.(Dongguan), qa.dg@baclcorp.com , 0086 0769 86858888
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. This device supports 20 MHz and 40 MHz bandwidth modes. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission exposure conditions are 0.03 W/kg, 0.21 W/kg, and 0.92 W/kg, respectively.

Applications

Application IDDatePurpose
bNz+bVvK5BFVGhhFBX+0IA==2019-12-10Original Equipment
aiIB6+aCxeDCZPZjQaB6nQ==2019-12-10Original Equipment
TXOU0VB1WUXx7iwF9GI5sQ==2019-12-10Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.5422.5ppm245KGXW22H
826.4-846.6 MHz0.0872.5ppm4M17F9W22H
1850.2-1909.8 MHz0.5472.5ppm245KGXW24E
1852.4-1907.6 MHz0.1062.5ppm4M17F9W24E
2402-2480 MHz0.000315C
2402-2480 MHz0.002000015C
2412-2462 MHz0.14315C

Grants

TCB Grant - Application TXOU0VB1WUXx7iwF9GI5sQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/10/2019

Application Dated: 12/10/2019
SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  

Output power listed is conducted.

EAS Grant - Application TXOU0VB1WUXx7iwF9GI5sQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
  Date of Grant: 12/10/2019

Application Dated: 12/10/2019
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.002  

Output power listed is conducted.



TCB Grant - Application bNz+bVvK5BFVGhhFBX+0IA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/10/2019

Application Dated: 12/10/2019
SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: Digital Transmission System
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0003  
15C 2412.0  -  2462.0 0.143  

Output power listed is conducted. This device supports 20 MHz and 40 MHz bandwidth modes. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission exposure conditions are 0.03 W/kg, 0.21 W/kg, and 0.92 W/kg, respectively.

EAS Grant - Application bNz+bVvK5BFVGhhFBX+0IA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
  Date of Grant: 12/10/2019

Application Dated: 12/10/2019
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: Digital Transmission System
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0003  
15C 2412.0  -  2462.0 0.143  

Output power listed is conducted. This device supports 20 MHz and 40 MHz bandwidth modes. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission exposure conditions are 0.03 W/kg, 0.21 W/kg, and 0.92 W/kg, respectively.



TCB Grant - Application aiIB6+aCxeDCZPZjQaB6nQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 12/10/2019

Application Dated: 12/10/2019
SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.542 2.5  PM 245KGXW
22H 826.4  -  846.6 0.087 2.5  PM 4M17F9W
24E 1850.2  -  1909.8 0.547 2.5  PM 245KGXW
24E 1852.4  -  1907.6 0.106 2.5  PM 4M17F9W

Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific, and simultaneous transmission exposure conditions are 0.08 W/kg, 0.71 W/kg, 0.92 W/kg, and 0.92 W/kg, respectively.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


EAS Grant - Application aiIB6+aCxeDCZPZjQaB6nQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SAGI MOBILE. S.A.S
CALLE 13 NUMERO 15-03 PISO 3
BOGOTA D.C.,
Colombia
  Date of Grant: 12/10/2019

Application Dated: 12/10/2019
 
Attention: JUAN ALVARO SALAZAR RAMIREZ , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUES-SAGIA630
Name of Grantee:  SAGI MOBILE. S.A.S
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Smart Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.542 2.5  PM 245KGXW
22H 826.4  -  846.6 0.087 2.5  PM 4M17F9W
24E 1850.2  -  1909.8 0.547 2.5  PM 245KGXW
24E 1852.4  -  1907.6 0.106 2.5  PM 4M17F9W

Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific, and simultaneous transmission exposure conditions are 0.08 W/kg, 0.71 W/kg, 0.92 W/kg, and 0.92 W/kg, respectively.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.



Mail To: