FCC ID 2AUKP-RZ001

Wireless Rootzone Sensor

by ROCKWOOL B.V. / Grodan

Grantee Code: 2AUKP   Product Code: RZ001
Latest application date: 2019-12-16

FCC ID Device Details

FCC ID2AUKP-RZ001
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUKP
Product CodeRZ001
Applicant BusinessROCKWOOL B.V. / Grodan 🇳🇱
Related Domains grodan.com
Equipment ClassWireless Rootzone Sensor
Test FirmTelefication B.V.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902-915 MHzOriginal Equipment2019-12-16

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2019-12-16PDF 283.9 KB
Internal PhotosInternal Photos2019-12-16PDF 649.1 KB
External PhotosExternal Photos2019-12-16PDF 283.7 KB
ID LabelID Label/Location Info2019-12-16PDF 57.8 KB
Label LocationID Label/Location Info2019-12-16PDF 78.2 KB
Test Setup PhotosTest Setup Photos2019-12-16PDF 566.1 KB
Test ReportTest Report2019-12-16PDF 2.3 MB
Declaration of authorizationCover Letter(s)2019-12-16PDF 265.2 KB
antenna informationCover Letter(s)2019-12-16PDF 116.6 KB
confidentialityCover Letter(s)2019-12-16PDF 611.1 KB
RF Expsoure ReportRF Exposure Info2019-12-16PDF 265.4 KB
RZ001-Block_Diagram Metadata onlyBlock DiagramPDF 86.6 KB
block diagram grosens Metadata onlyBlock DiagramPDF 80.1 KB
block diagram rootzone Metadata onlyBlock DiagramPDF 86 KB
RZ001-Schematics_1of2 Metadata onlySchematicsPDF 111.4 KB
RZ001-Schematics_2of2 Metadata onlySchematicsPDF 70.4 KB
schematics rootzone Metadata onlySchematicsPDF 111.4 KB
Operational Description Metadata onlyOperational DescriptionPDF 119.5 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 1.1 MB

Application Information

Application IDohViy0wkspAFg0eOyjVorQ==
Final Action Date2019-12-16
Application PurposeOriginal Equipment
Applicant FRN0028806198
ModelRZ001
Frequency Range902-915 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless Rootzone Sensor
Responsible PartyPaul Bouwens, paul.bouwens@grodan.com , +31475353535
AgentErice Erice Erice, ControlPortals, info@controlportals.com , 31(0)665-372-000
Technical ContactPaul Bouwens, ROCKWOOL B.V. / Grodan, paul.bouwens@grodan.com , 31475353535
Non-Technical ContactPaul Bouwens, ROCKWOOL B.V. / Grodan, paul.bouwens@grodan.com , 31475353535
Test FirmWillem Jong, Telefication B.V., wjjong@telefication.com , +31 889 983 600
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
ohViy0wkspAFg0eOyjVorQ==2019-12-16Original Equipment

Equipment Authorization

FrequencyOutputRules
902-915 MHz0.04815C
2402-2480 MHz0.004215C

Grants

TCB Grant - Application ohViy0wkspAFg0eOyjVorQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/16/2019

Application Dated: 12/10/2019
ROCKWOOL B.V. / Grodan
Industrieweg 15
Roermond, 6045 JG
Netherlands
 
Attention: Paul Bouwens

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUKP-RZ001
Name of Grantee:  ROCKWOOL B.V. / Grodan
Equipment Class: Digital Transmission System
Notes: Wireless Rootzone Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  915.0 0.048  
15C 2402.0  -  2480.0 0.0042  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application ohViy0wkspAFg0eOyjVorQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ROCKWOOL B.V. / Grodan
Industrieweg 15
Roermond, 6045 JG
Netherlands
  Date of Grant: 12/16/2019

Application Dated: 12/10/2019
 
Attention: Paul Bouwens

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUKP-RZ001
Name of Grantee:  ROCKWOOL B.V. / Grodan
Equipment Class: Digital Transmission System
Notes: Wireless Rootzone Sensor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  915.0 0.048  
15C 2402.0  -  2480.0 0.0042  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: