FCC ID 2AUMJ-W107X-V

Personal Mobile Alarm System

by Shenzhen Eview GPS Technology

Grantee Code: 2AUMJ   Product Code: W107XV
Latest application date: 2026-03-30

FCC ID Device Details

FCC ID2AUMJ-W107X-V
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUMJ
Product CodeW107XV
Applicant BusinessShenzhen Eview GPS Technology 🇨🇳
Related Domains eviewltd.com miramontsolutions.com
Equipment ClassPersonal Mobile Alarm System
Test FirmBTF Testing Lab (Shenzhen) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2026-03-30
1860-1900 MHzOriginal Equipment2026-03-30

Exhibits

DocumentTypeAvailableFile
LabelID Label/Location Info2026-03-30PDF 65.7 KB
Appendix-LTE_band_4_1-96Test Setup Photos2026-03-30PDF 5 MB
Antenna ReportTest Report2026-03-30PDF 1.2 MB
Appendix-2.4G WIFITest Report2026-03-30PDF 3.5 MB
Appendix-BLETest Report2026-03-30PDF 2.3 MB
Appendix-LTE_band_13Test Report2026-03-30PDF 5.4 MB
Appendix-LTE_band_2_1-96Test Report2026-03-30PDF 5 MB
Appendix-LTE_band_2_148-192Test Report2026-03-30PDF 3 MB
Appendix-LTE_band_2_97-147Test Report2026-03-30PDF 3.5 MB
Appendix-LTE_band_4_148-192Test Report2026-03-30PDF 3 MB
Appendix-LTE_band_4_97-147Test Report2026-03-30PDF 3.5 MB
SAR Test ReportRF Exposure Info2026-03-30PDF 2.1 MB
Test Report 2.4G WIFITest Report2026-03-30PDF 1.1 MB
Test Report BLETest Report2026-03-30PDF 1.1 MB
Test Report LTETest Report2026-03-30PDF 660 KB
Attestation Statements-KasperskyAttestation Statements2026-03-30PDF 142.1 KB
Attestation Statements-Not CoveredAttestation Statements2026-03-30PDF 109.9 KB
US AgentAttestation Statements2026-03-30PDF 60 KB
Confidentiality RequestCover Letter(s)2026-03-30PDF 98.4 KB
POACover Letter(s)2026-03-30PDF 91.2 KB
SAR Calibration ReportRF Exposure Info2026-03-30PDF 1.3 MB
User Manual Metadata onlyUsers Manual2026-09-26PDF 2.4 MB
Internal Photo Metadata onlyInternal Photos2026-09-26PDF 1.5 MB
External Photo Metadata onlyExternal Photos2026-09-26PDF 913.5 KB
SAR Test Setup Photos Metadata onlyTest Setup Photos2026-09-26PDF 1.1 MB
Test Setup Photos Metadata onlyTest Setup Photos2026-09-26PDF 351.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 142 KB
Schematics Metadata onlySchematicsPDF 251 KB
Operation Description Metadata onlyOperational DescriptionPDF 37.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 209 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 61.7 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 61.7 KB

Application Information

Application IDoH4gzJ2nV4zO07BLRMgC3Q==
Final Action Date2026-03-30
Application PurposeOriginal Equipment
Applicant FRN0028821890
ModelW107X-V
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPersonal Mobile Alarm System
Responsible PartyBella Wang, sales@eviewltd.com , 86-15899795842
Non-Technical ContactWenyi Wang, MIRAMONT SOLUTIONS LLC, wenyiwang@miramontsolutions.com , 9514013633
Test FirmRyan CJ, BTF Testing Lab (Shenzhen) Co., Ltd., Ryan.cj@btf-lab.com , 86-755-23146130
TCB Emailjoe_chew@derycom-us.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
oH4gzJ2nV4zO07BLRMgC3Q==2026-03-30Original Equipment
TkAyRFlQMmg/vmjzJUgL3g==2026-03-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1860-1900 MHz0.14890.0022 PM18M3G7D24E
1860-1900 MHz0.13150.0021 PM5M04W7D24E
1720-1745 MHz0.07740.0024 PM18M3G7D27
1720-1745 MHz0.06870.0028 PM5M02W7D27
1710.7-1754.3 MHz0.07830.0023 PM1M19G7D27
1710.7-1754.3 MHz0.05850.0018 PM1M19W7D27
782 MHz0.03170.0019 PM9M02G7D27
782 MHz0.02560.0013 PM4M98W7D27
2402-2480 MHz0.000715CCC
2412-2462 MHz0.06115CCC

Grants

TCB Grant - Application TkAyRFlQMmg/vmjzJUgL3g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DERYCOM CERTIFICATION SERVICES, INC.
1100 Falcon Avenue
Glencoe, MN 55336
Date of Grant: 03/30/2026

Application Dated: 03/30/2026
Shenzhen Eview GPS Technology
Rm 201, building 1-A, Nankechuang Yuangu,
Dalang, Longhua District,
Shenzhen, 518110
China
 
Attention: Bella Wang , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUMJ-W107X-V
Name of Grantee:  Shenzhen Eview GPS Technology
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Personal Mobile Alarm System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1860.0  -  1900.0 0.1489 0.0022  PM 18M3G7D
24E 1860.0  -  1900.0 0.1315 0.0021  PM 5M04W7D
27 1720.0  -  1745.0 0.0774 0.0024  PM 18M3G7D
27 1720.0  -  1745.0 0.0687 0.0028  PM 5M02W7D
27 1710.7  -  1754.3 0.0783 0.0023  PM 1M19G7D
27 1710.7  -  1754.3 0.0585 0.0018  PM 1M19W7D
27 782.0  -  782.0 0.0317 0.0019  PM 9M02G7D
27 782.0  -  782.0 0.0256 0.0013  PM 4M98W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. It supports LTE (QPSK, 16QAM) B2, B4 and B13. Channel Bandwidth (5/10 MHz) for LTE B13. Channel Bandwidth (1.4/3/5/10/15/20 MHz) for LTE B2 and B4. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the Head (Next-to-mouth 10mm) and Limb Worn (Wrist-worn 0mm) operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for Next-to-mouth (separation 10 mm) exposure condition is 0.77 W/kg. The highest reported simultaneous SAR for Next-to-mouth (separation 10 mm) exposure condition is 1.56 W/kg. The highest reported standalone 10g SAR for Wrist-worn (separation 0 mm) exposure condition is 1.98 W/kg. The highest reported simultaneous SAR for Wrist-worn (separation 0 mm) exposure condition is 3.91 W/kg.

TCB Grant - Application oH4gzJ2nV4zO07BLRMgC3Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DERYCOM CERTIFICATION SERVICES, INC.
1100 Falcon Avenue
Glencoe, MN 55336
Date of Grant: 03/30/2026

Application Dated: 03/30/2026
Shenzhen Eview GPS Technology
Rm 201, building 1-A, Nankechuang Yuangu,
Dalang, Longhua District,
Shenzhen, 518110
China
 
Attention: Bella Wang , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUMJ-W107X-V
Name of Grantee:  Shenzhen Eview GPS Technology
Equipment Class: Digital Transmission System
Notes: Personal Mobile Alarm System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0007  
CC 15C 2412.0  -  2462.0 0.061  

Output power listed is conducted power. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the Head (Next-to-mouth 10mm) and Limb Worn (Wrist-worn 0mm) operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for Next-to-mouth (separation 10 mm) exposure condition is 0.79 W/kg. The highest reported simultaneous SAR for Next-to-mouth (separation 10 mm) exposure condition is 1.56 W/kg. The highest reported standalone 10g SAR for Wrist-worn (separation 0 mm) exposure condition is 1.93 W/kg. The highest reported simultaneous SAR for Wrist-worn (separation 0 mm) exposure condition is 3.91 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.