FCC ID 2AUXY-ICX120

ICX-120 boiler controller is part of the Integras Gateway system which is operated remotely via wireless Gateway (LAN2RF) modules.

by IBC Technologies Inc.

Grantee Code: 2AUXY   Product Code: ICX120
Latest application date: 2020-08-31

FCC ID Device Details

FCC ID2AUXY-ICX120
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUXY
Product CodeICX120
Applicant BusinessIBC Technologies Inc. 🇨🇦
Related Domains ibcboiler.com
Equipment ClassICX-120 boiler controller is part of the Integras Gateway system which is operated remotely via wireless Gateway (LAN2RF) modules.
Test FirmQAI LABORATORIES LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902-928 MHzOriginal Equipment2020-08-31

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2020-08-31PDF 3.2 MB
Internal Photos caseInternal Photos2020-08-31PDF 4.1 MB
Internal Photos pcbInternal Photos2020-08-31PDF 3.5 MB
External PhotosExternal Photos2020-08-31PDF 4.2 MB
Label LocationID Label/Location Info2020-08-31PDF 641.3 KB
Label SampleID Label/Location Info2020-08-31PDF 433.6 KB
TsupTest Setup Photos2020-08-31PDF 480.8 KB
Test ReportTest Report2020-08-31PDF 2.9 MB
Confidentiality LetterCover Letter(s)2020-08-31PDF 134.3 KB
Cover LetterCover Letter(s)2020-08-31PDF 129.2 KB
POA LetterCover Letter(s)2020-08-31PDF 279.6 KB
Block Diagram Metadata onlyBlock DiagramPDF 61.6 KB
Schematics 240024 Metadata onlySchematicsPDF 304.4 KB
Schematics 240034 Metadata onlySchematicsPDF 841 KB
Operation Description Metadata onlyOperational DescriptionPDF 11.6 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 146.8 KB

Application Information

Application IDXZO9YolKyEbkuWgWCnhAMA==
Final Action Date2020-08-31
Application PurposeOriginal Equipment
Applicant FRN0028904241
ModelICX120
Frequency Range902-928 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionICX-120 boiler controller is part of the Integras Gateway system which is operated remotely via wireless Gateway (LAN2RF) modules.
Responsible PartyClifford Snelling, Engineering Manager, csnelling@ibcboiler.com , 604-877-0277
Test FirmParminder Singh, QAI LABORATORIES LTD., psingh@qai.org , 604-527-8378
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
XZO9YolKyEbkuWgWCnhAMA==2020-08-31Original Equipment

Equipment Authorization

FrequencyOutputRules
902-928 MHz0.009000015C

Grants

TCB Grant - Application XZO9YolKyEbkuWgWCnhAMA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 08/31/2020

Application Dated: 08/31/2020
IBC Technologies Inc.
8015 North Fraser Way
Burnaby, V5J 5M8
Canada
 
Attention: Clifford Snelling , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXY-ICX120
Name of Grantee:  IBC Technologies Inc.
Equipment Class: Digital Transmission System
Notes: ICX-120 boiler controller is part of the Integras Gateway system which is operated remotely via wireless Gateway (LAN2RF) modules.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.009  

Output Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application XZO9YolKyEbkuWgWCnhAMA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IBC Technologies Inc.
8015 North Fraser Way
Burnaby, V5J 5M8
Canada
  Date of Grant: 08/31/2020

Application Dated: 08/31/2020
 
Attention: Clifford Snelling , Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXY-ICX120
Name of Grantee:  IBC Technologies Inc.
Equipment Class: Digital Transmission System
Notes: ICX-120 boiler controller is part of the Integras Gateway system which is operated remotely via wireless Gateway (LAN2RF) modules.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.009  

Output Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: