FCC ID 2AV3W-TL21

Tablet PC

by VitalTech Affiliates LLC

Grantee Code: 2AV3W   Product Code: TL21
Latest application date: 2020-07-17

FCC ID Device Details

FCC ID2AV3W-TL21
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AV3W
Product CodeTL21
Applicant BusinessVitalTech Affiliates LLC 🇺🇸
Related Domains vitaltech.com
Equipment ClassTablet PC
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2020-07-17
2402-2480 MHzOriginal Equipment2020-07-17
699.7-715.3 MHzOriginal Equipment2020-07-17
2402-2480 MHzOriginal Equipment2020-07-17

Exhibits

DocumentTypeAvailableFile
User_ManualUsers Manual2020-07-17PDF 2.9 MB
User_MunaulUsers Manual2020-07-17PDF 2.9 MB
INT_PHOTOInternal Photos2020-07-17PDF 2.7 MB
Int_PhotosInternal Photos2020-07-17PDF 4.1 MB
Internal PhotosInternal Photos2020-07-17PDF 2.7 MB
Internal_PhotosInternal Photos2020-07-17PDF 4.1 MB
Internal_photosInternal Photos2020-07-17PDF 2.7 MB
Internal_photosInternal Photos2020-07-17PDF 4.1 MB
Ext_PhotosExternal Photos2020-07-17PDF 2.3 MB
External_PhotosExternal Photos2020-07-17PDF 2.3 MB
Label_and_Label_LocationID Label/Location Info2020-07-17PDF 351.1 KB
Label_locationID Label/Location Info2020-07-17PDF 351.1 KB
Test Setup PhotosTest Setup Photos2020-07-17PDF 848.7 KB
Test_Setup_PhotosTest Setup Photos2020-07-17PDF 1.8 MB
Test_Setup_photoTest Setup Photos2020-07-17PDF 376.8 KB
Test_Setup_photosTest Setup Photos2020-07-17PDF 1.8 MB
2.4G WIFI_FCC Template-1Test Report2020-07-17PDF 3.7 MB
2.4G WIFI_FCC Template-2Test Report2020-07-17PDF 4.5 MB
2.4G WIFI_FCC Template-3Test Report2020-07-17PDF 3.8 MB
5.2G WLAN_FCC Templat-1Test Report2020-07-17PDF 4 MB
5.2G WLAN_FCC Templat-2Test Report2020-07-17PDF 4.3 MB
5.8G WLAN_FCC Template-1Test Report2020-07-17PDF 2.7 MB
5.8G WLAN_FCC Template-2Test Report2020-07-17PDF 2.9 MB
5.8G WLAN_FCC Template-3Test Report2020-07-17PDF 3.2 MB
BT 3.0_FCC Template-1Test Report2020-07-17PDF 4.5 MB
BT 3.0_FCC Template-2Test Report2020-07-17PDF 3.2 MB
BT 3.0_FCC Template-3Test Report2020-07-17PDF 3.8 MB
BT LE 4.0_FCC TemplateTest Report2020-07-17PDF 3 MB
Band 12-1Test Report2020-07-17PDF 3.1 MB
Band 12-2Test Report2020-07-17PDF 3.8 MB
Band 17Test Report2020-07-17PDF 3.7 MB
Band 2-1Test Report2020-07-17PDF 2.6 MB
Band 2-2Test Report2020-07-17PDF 3.9 MB
Band 2-3Test Report2020-07-17PDF 4 MB
Band 4-1Test Report2020-07-17PDF 2.5 MB
Band 4-2Test Report2020-07-17PDF 3.7 MB
Band 4-3Test Report2020-07-17PDF 4.1 MB
Band 5-1Test Report2020-07-17PDF 3.1 MB
Band 5-2Test Report2020-07-17PDF 3.9 MB
LCS200403014AEA-BT3.0Test Report2020-07-17PDF 1 MB
LCS200403014AEC_BT LETest Report2020-07-17PDF 1,016.8 KB
LCS200403014AED_2.4G WIFITest Report2020-07-17PDF 1.1 MB
LCS200403014AEE_5.2G WLANTest Report2020-07-17PDF 1.1 MB
LCS200403014AEF_5.8G WLANTest Report2020-07-17PDF 1.1 MB
LCS200403014AEG_GSM-1Test Report2020-07-17PDF 3.7 MB
LCS200403014AEG_GSM-2Test Report2020-07-17PDF 3.5 MB
LCS200403014AEG_GSM-3Test Report2020-07-17PDF 1.5 MB
LCS200403014AEH_WCDMATest Report2020-07-17PDF 4.6 MB
LCS200403014AEI_LTETest Report2020-07-17PDF 734.8 KB
Agent Authorization Rev 1.0Cover Letter(s)2020-07-17PDF 54.5 KB
Agent_AuthorizationCover Letter(s)2020-07-17PDF 54.5 KB
Declaration Letter of Model DifferenceCover Letter(s)2020-07-17PDF 50.4 KB
FCC Software Configuration Control DeclarationCover Letter(s)2020-07-17PDF 78.4 KB
FCC_Short_&_Long_Term_Confidentiality_RequestCover Letter(s)2020-07-17PDF 51.8 KB
LCS200403014AEB SAR REPORT-1RF Exposure Info2020-07-17PDF 3.7 MB
LCS200403014AEB SAR REPORT-2RF Exposure Info2020-07-17PDF 3 MB
LCS200403014AEB SAR REPORT-3RF Exposure Info2020-07-17PDF 3.1 MB
LCS200403014AEB SAR REPORT-4RF Exposure Info2020-07-17PDF 3.9 MB
LCS200403014AEB SAR REPORT-5RF Exposure Info2020-07-17PDF 4.1 MB
LCS200403014AEB SAR REPORT-6RF Exposure Info2020-07-17PDF 3.8 MB
LCS200403014AEB SAR REPORT-7RF Exposure Info2020-07-17PDF 3.4 MB
Block_Diagram Metadata onlyBlock DiagramPDF 15 KB
block_diagram Metadata onlyBlock DiagramPDF 15 KB
SCH Metadata onlySchematicsPDF 460.7 KB
Schematic Metadata onlySchematicsPDF 460.7 KB
Operation_Description Metadata onlyOperational DescriptionPDF 62.8 KB
Operational-Description Metadata onlyOperational DescriptionPDF 62.8 KB
Declaration of Software Security Requirements For U-NII Devices Metadata onlySDR Software/Security InfPDF 74.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 138.8 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 164 KB
Tune up Procedurer Metadata onlyParts List/Tune Up InfoPDF 164 KB

Application Information

Application IDu+9RrmJkFgu9Rz+hs3KtmA==
Final Action Date2020-07-17
Application PurposeOriginal Equipment
Applicant FRN0029393279
ModelTL21
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionTablet PC
Responsible PartyRaji Kumar, VP Operations, raji@vitaltech.com , 972-544-7077
Technical ContactVitalTech Affiliates LLC, raji@vitaltech.com
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.13 W/kg, 0.13 W/kg and 1.56 W/kg respectively.

Applications

Application IDDatePurpose
u+9RrmJkFgu9Rz+hs3KtmA==2020-07-17Original Equipment
QESk7dINjkZD/mOgCBI/1g==2020-07-17Original Equipment
JusxFlX9ZGpdHSFVxxVIow==2020-07-17Original Equipment
CE76vIPYju1ltWo0g0pdHg==2020-07-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
699.7-715.3 MHz0.1262.5ppm1M09G7D27
699.7-715.3 MHz0.1292.5ppm1M08W7D27
704-711 MHz0.1222.5ppm8M94G7D27
704-711 MHz0.1262.5ppm8M94W7D27
706.5-713.5 MHz0.1312.5ppm4M48W7D27
709-711 MHz0.1252.5ppm8M93G7D27
709-711 MHz0.1262.5ppm8M94W7D27
825.5-847.5 MHz0.1282.5ppm2M69G7D22H
826.4-846.6 MHz0.1282.5ppm4M13F9W22H
829-844 MHz0.1272.5ppm8M95G7D22H
829-844 MHz0.132.5ppm8M94W7D22H
1715-1750 MHz0.1852.5ppm8M94G7D27
1717.5-1747.5 MHz0.1842.5ppm13M4W7D27
1720-1745 MHz0.1712.5ppm17M9G7D27
1720-1745 MHz0.1792.5ppm17M8W7D27
1852.4-1907.6 MHz0.2042.5ppm4M14F9W24E
1855-1905 MHz0.1852.5ppm8M92W7D24E
1860-1900 MHz0.1852.5ppm17M9G7D24E
1860-1900 MHz0.1742.5ppm17M9W7D24E
2402-2480 MHz0.00115CCC
2402-2480 MHz0.003000015CCC
2412-2462 MHz0.0315CCC
5180-5240 MHz0.00815E38, CC
5745-5825 MHz0.00815E38, CC

Grants

TCB Grant - Application u+9RrmJkFgu9Rz+hs3KtmA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/17/2020

Application Dated: 07/17/2020
VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Tablet PC
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.008  
38 CC 15E 5745.0  -  5825.0 0.008  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.13 W/kg, 0.13 W/kg and 1.56 W/kg respectively.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application u+9RrmJkFgu9Rz+hs3KtmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
United States
  Date of Grant: 07/17/2020

Application Dated: 07/17/2020
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Tablet PC
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.008  
38 CC 15E 5745.0  -  5825.0 0.008  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.13 W/kg, 0.13 W/kg and 1.56 W/kg respectively.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application QESk7dINjkZD/mOgCBI/1g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/17/2020

Application Dated: 07/17/2020
VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Tablet PC
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  

Power listed is the maximum conducted output power.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application QESk7dINjkZD/mOgCBI/1g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
United States
  Date of Grant: 07/17/2020

Application Dated: 07/17/2020
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Tablet PC
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  

Power listed is the maximum conducted output power.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application JusxFlX9ZGpdHSFVxxVIow==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/17/2020

Application Dated: 07/17/2020
VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: PCS Licensed Transmitter
Notes: Tablet PC
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.127 2.5  PM 248KGXW
24E 1850.2  -  1909.8 0.213 2.5  PM 249KGXW
22H 826.4  -  846.6 0.128 2.5  PM 4M13F9W
24E 1852.4  -  1907.6 0.204 2.5  PM 4M14F9W
24E 1860.0  -  1900.0 0.185 2.5  PM 17M9G7D
24E 1860.0  -  1900.0 0.174 2.5  PM 17M9W7D
24E 1855.0  -  1905.0 0.185 2.5  PM 8M92W7D
27 1720.0  -  1745.0 0.171 2.5  PM 17M9G7D
27 1720.0  -  1745.0 0.179 2.5  PM 17M8W7D
27 1715.0  -  1750.0 0.185 2.5  PM 8M94G7D
27 1717.5  -  1747.5 0.184 2.5  PM 13M4W7D
22H 829.0  -  844.0 0.127 2.5  PM 8M95G7D
22H 829.0  -  844.0 0.13 2.5  PM 8M94W7D
22H 825.5  -  847.5 0.128 2.5  PM 2M69G7D
27 704.0  -  711.0 0.122 2.5  PM 8M94G7D
27 704.0  -  711.0 0.126 2.5  PM 8M94W7D
27 699.7  -  715.3 0.126 2.5  PM 1M09G7D
27 699.7  -  715.3 0.129 2.5  PM 1M08W7D
27 709.0  -  711.0 0.125 2.5  PM 8M93G7D
27 709.0  -  711.0 0.126 2.5  PM 8M94W7D
27 706.5  -  713.5 0.131 2.5  PM 4M48W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 1.43 W/kg, 1.43 W/kg and 1.60 W/kg respectively.

EAS Grant - Application JusxFlX9ZGpdHSFVxxVIow==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
United States
  Date of Grant: 07/17/2020

Application Dated: 07/17/2020
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: PCS Licensed Transmitter
Notes: Tablet PC
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.127 2.5  PM 248KGXW
24E 1850.2  -  1909.8 0.213 2.5  PM 249KGXW
22H 826.4  -  846.6 0.128 2.5  PM 4M13F9W
24E 1852.4  -  1907.6 0.204 2.5  PM 4M14F9W
24E 1860.0  -  1900.0 0.185 2.5  PM 17M9G7D
24E 1860.0  -  1900.0 0.174 2.5  PM 17M9W7D
24E 1855.0  -  1905.0 0.185 2.5  PM 8M92W7D
27 1720.0  -  1745.0 0.171 2.5  PM 17M9G7D
27 1720.0  -  1745.0 0.179 2.5  PM 17M8W7D
27 1715.0  -  1750.0 0.185 2.5  PM 8M94G7D
27 1717.5  -  1747.5 0.184 2.5  PM 13M4W7D
22H 829.0  -  844.0 0.127 2.5  PM 8M95G7D
22H 829.0  -  844.0 0.13 2.5  PM 8M94W7D
22H 825.5  -  847.5 0.128 2.5  PM 2M69G7D
27 704.0  -  711.0 0.122 2.5  PM 8M94G7D
27 704.0  -  711.0 0.126 2.5  PM 8M94W7D
27 699.7  -  715.3 0.126 2.5  PM 1M09G7D
27 699.7  -  715.3 0.129 2.5  PM 1M08W7D
27 709.0  -  711.0 0.125 2.5  PM 8M93G7D
27 709.0  -  711.0 0.126 2.5  PM 8M94W7D
27 706.5  -  713.5 0.131 2.5  PM 4M48W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 1.43 W/kg, 1.43 W/kg and 1.60 W/kg respectively.



TCB Grant - Application CE76vIPYju1ltWo0g0pdHg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/17/2020

Application Dated: 07/17/2020
VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Digital Transmission System
Notes: Tablet PC
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001  
CC 15C 2412.0  -  2462.0 0.03  

Power listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.07 W/kg, 0.07 W/kg and 1.56 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application CE76vIPYju1ltWo0g0pdHg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

VitalTech Affiliates LLC
6652 PINECREST DR STE 400
PLANO, TX 75024-2957
United States
  Date of Grant: 07/17/2020

Application Dated: 07/17/2020
 
Attention: Raji Kumar , VP Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AV3W-TL21
Name of Grantee:  VitalTech Affiliates LLC
Equipment Class: Digital Transmission System
Notes: Tablet PC
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001  
CC 15C 2412.0  -  2462.0 0.03  

Power listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.07 W/kg, 0.07 W/kg and 1.56 W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.