FCC ID 2AVCKLFP3300

P Series

by LINKFLOW Co., Ltd.

Grantee Code: 2AVCK   Product Code: LFP3300
Latest application date: 2025-01-26

FCC ID Device Details

FCC ID2AVCKLFP3300
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AVCK
Product CodeLFP3300
Applicant BusinessLINKFLOW Co., Ltd. 🇰🇷
Related Domains linkflow.co.kr
Equipment ClassP Series
Test FirmKES Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2025-01-26
2412-2462 MHzOriginal Equipment2025-01-25
2402-2480 MHzOriginal Equipment2025-01-25

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-07-25PDF 1 MB
User manualUsers Manual2025-07-25PDF 1 MB
Internal PhotosInternal Photos2025-07-25PDF 2.7 MB
Internal photosInternal Photos2025-07-25PDF 2.7 MB
internal photosInternal Photos2025-07-25PDF 2.7 MB
External PhotosExternal Photos2025-07-25PDF 1.7 MB
Label and locationID Label/Location Info2025-01-26PDF 58.2 KB
Label&LocationID Label/Location Info2025-01-25PDF 58.2 KB
label locationID Label/Location Info2025-01-25PDF 58.2 KB
T Setup photos SARTest Setup Photos2025-07-25PDF 715.1 KB
Test SetupTest Setup Photos2025-07-25PDF 660.4 KB
Test Setup PhotosTest Setup Photos2025-07-25PDF 660.4 KB
Test Setup photo SARTest Setup Photos2025-07-25PDF 715.1 KB
Test photos SARTest Setup Photos2025-07-25PDF 715.1 KB
Antenna specificationTest Report2025-01-26PDF 1.2 MB
RFTestreport 15.407-1Test Report2025-01-26PDF 5.5 MB
RFTestreport 15.407-2Test Report2025-01-26PDF 5.5 MB
RFTestreport 15.407-3Test Report2025-01-26PDF 5.3 MB
RFTestreport 15.407-4Test Report2025-01-26PDF 3.8 MB
Test Report SARRF Exposure Info2025-01-26PDF 4.8 MB
Antenna SpecificationTest Report2025-01-25PDF 1.2 MB
RFTestreport 15.247 BT-1Test Report2025-01-25PDF 4.9 MB
RFTestreport 15.247 BT-2Test Report2025-01-25PDF 2.9 MB
RFTestreport 15.247 NonFHSS-1Test Report2025-01-25PDF 5.4 MB
RFTestreport 15.247 NonFHSS-2Test Report2025-01-25PDF 4.2 MB
RFTestreport 15.247 NonFHSS-3Test Report2025-01-25PDF 5 MB
Test report SARRF Exposure Info2025-01-25PDF 4.8 MB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2025-01-26PDF 139 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2025-01-26PDF 133 KB
2.911 (d)(7)USAgentforServiceofProcessv1.2Attestation Statements2025-01-26PDF 282.6 KB
2.911 d 5 ii CertificiationApplicantv1.3Attestation Statements2025-01-25PDF 133 KB
2.911 (d)(5)(i) Certification Equipment Type v1.2Attestation Statements2025-01-25PDF 139 KB
2.911 (d)(5)(ii) Certificiation Applicant v1.3Attestation Statements2025-01-25PDF 133 KB
2.911 (d)(7) US Agent for Service of Process v1.4Attestation Statements2025-01-25PDF 282.6 KB
2.911 (d)(7)USAgentforServiceofProcessv1.3Attestation Statements2025-01-25PDF 282.6 KB
FCC LongTermConfidentialityRequestCover Letter(s)2025-01-26PDF 62.9 KB
FCC Software Configuration Control Declaration Rev1.1Cover Letter(s)2025-01-26PDF 60.2 KB
Family Declaration LetterCover Letter(s)2025-01-26PDF 52.4 KB
Letter of Authorization Rev 2.0Cover Letter(s)2025-01-26PDF 11 KB
FCC Long&shortTermOnlyConfidentialityRequestRev4.0Cover Letter(s)2025-01-25PDF 62.9 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2025-01-25PDF 62.9 KB
BLOCK Diagram Metadata onlyBlock DiagramPDF 335.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 335.5 KB
SCH Metadata onlySchematicsPDF 3.1 MB
OP Metadata onlyOperational DescriptionPDF 269 KB
Software security operational description Metadata onlySDR Software/Security Info.PDF 111.8 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 122.1 KB

Application Information

Application IDYbAltQuPW6oZpVICV/vncw==
Final Action Date2025-01-26
Application PurposeOriginal Equipment
Applicant FRN0029038510
ModelLFP3300
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionP Series
Responsible PartyMinhwan Kim, wayne@linkflow.co.kr , +82-10-5801-6445
Technical ContactLINKFLOW Co., Ltd., wayne@linkflow.co.kr
Test FirmInsung Ryu, KES Co., Ltd, kes@kes.co.kr , 82-31-425-6200
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/25/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 1.33W/kg and 1.53W/kg respectively.

Applications

Application IDDatePurpose
YbAltQuPW6oZpVICV/vncw==2025-01-26Original Equipment
UdDWw7ZWvI1ofcqbNBeCiQ==2025-01-25Original Equipment
8COTeT0Yi5XeL7eRNWa64A==2025-01-25Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.0050215CCC
2402-2480 MHz0.012420015CCC
2412-2462 MHz0.1610715CCC
5180-5240 MHz0.0261915ECC
5745-5825 MHz0.0380215ECC

Grants

TCB Grant - Application YbAltQuPW6oZpVICV/vncw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/26/2025

Application Dated: 01/25/2025
LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: P Series
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.02619  
CC 15E 5745.0  -  5825.0 0.03802  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 1.33W/kg and 1.53W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application YbAltQuPW6oZpVICV/vncw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
  Date of Grant: 01/26/2025

Application Dated: 01/25/2025
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: P Series
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.02619  
CC 15E 5745.0  -  5825.0 0.03802  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 1.33W/kg and 1.53W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application UdDWw7ZWvI1ofcqbNBeCiQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/25/2025

Application Dated: 01/25/2025
LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Digital Transmission System
Notes: P Series
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00502  
CC 15C 2412.0  -  2462.0 0.16107  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 1.26W/kg and 1.53W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application UdDWw7ZWvI1ofcqbNBeCiQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
  Date of Grant: 01/25/2025

Application Dated: 01/25/2025
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Digital Transmission System
Notes: P Series
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00502  
CC 15C 2412.0  -  2462.0 0.16107  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 1.26W/kg and 1.53W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 8COTeT0Yi5XeL7eRNWa64A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/25/2025

Application Dated: 01/25/2025
LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: P Series
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.01242  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 0.20W/kg and 1.53W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 8COTeT0Yi5XeL7eRNWa64A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LINKFLOW Co., Ltd.
3,4F, 54, Nonhyeon-ro 2-gil, Gangnam-gu
Seoul,
South Korea
  Date of Grant: 01/25/2025

Application Dated: 01/25/2025
 
Attention: Minhwan Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AVCKLFP3300
Name of Grantee:  LINKFLOW Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: P Series
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.01242  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous transmission use conditions is 0.20W/kg and 1.53W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: