FCC ID 2AVFWA3441W20
PathSpot Hand Scanner
by PathSpot Technologies, Inc.
Grantee Code: 2AVFW Product Code: A3441W20
Latest application date: 2020-01-20
FCC ID Device Details
| FCC ID | 2AVFWA3441W20 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AVFW |
| Product Code | A3441W20 |
| Applicant Business | PathSpot Technologies, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | PathSpot Hand Scanner |
| Test Firm | Dongguan Dongdian Testing Service Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2020-01-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User-Manual | Users Manual | 2020-07-13 | PDF 204.7 KB |
| User_Manual | Users Manual | 2020-07-13 | PDF 200 KB |
| Internal_photos | Internal Photos | 2020-07-13 | PDF 1.3 MB |
| External_Photos | External Photos | 2020-07-13 | PDF 632.8 KB |
| Label | ID Label/Location Info | 2020-01-20 | PDF 786.4 KB |
| Label_Location | ID Label/Location Info | 2020-01-20 | PDF 34.3 KB |
| Test_Setup_Photos | Test Setup Photos | 2020-07-13 | PDF 1 MB |
| FCC ID Report 2.4g wifi_compressed | Test Report | 2020-01-20 | PDF 2.4 MB |
| FCC ID Report BT BLE_compressed | Test Report | 2020-01-20 | PDF 1.5 MB |
| Agent_Authorization_Rev_1.0 | Cover Letter(s) | 2020-01-20 | PDF 32.6 KB |
| FCC_Short_&_Long_Term_Confidentiality | Cover Letter(s) | 2020-01-20 | PDF 32.6 KB |
| FCC RF Exposure Report | RF Exposure Info | 2020-01-20 | PDF 761.3 KB |
| Block_Diagram Metadata only | Block Diagram | PDF 106.1 KB | |
| Schematic Metadata only | Schematics | PDF 1 MB | |
| Operation_Description Metadata only | Operational Description | PDF 160.1 KB |
Application Information
| Application ID | xZHSd4uGWfcY6uqTgBkUJQ== |
|---|---|
| Final Action Date | 2020-01-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0029045531 |
| Model | A3441W20 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | PathSpot Hand Scanner |
| Responsible Party | Taylor Waanders, dutch@pathspottech.com |
| Technical Contact | PathSpot Technologies, Inc., dutch@pathspottech.com |
| Test Firm | Mr. Jamy Yu, Dongguan Dongdian Testing Service Co., Ltd., jamy@dgieie.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/13/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xZHSd4uGWfcY6uqTgBkUJQ== | 2020-01-20 | Original Equipment |
Grants
TCB Grant - Application xZHSd4uGWfcY6uqTgBkUJQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 01/20/2020 Application Dated: 01/20/2020 |
| PathSpot Technologies, Inc. |
| 115 Broadway, Floor 5 |
| New York, NY 10006 |
| Attention: Taylor Waanders |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVFWA3441W20 |
| Name of Grantee: | PathSpot Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | PathSpot Hand Scanner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.00023 | |||
| 15C | 2412.0 - 2462.0 | 0.04227 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application xZHSd4uGWfcY6uqTgBkUJQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
PathSpot Technologies, Inc. 115 Broadway, Floor 5 New York, NY 10006 United States |
Date of Grant: 01/20/2020 Application Dated: 01/20/2020 |
| Attention: Taylor Waanders |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVFWA3441W20 |
| Name of Grantee: | PathSpot Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | PathSpot Hand Scanner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.00023 | |||
| 15C | 2412.0 - 2462.0 | 0.04227 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| Mail To: |