FCC ID 2AVRB-METOR-900M
Metor 900M Walk-Through Metal Detector
by Rapiscan Systems
Grantee Code: 2AVRB Product Code: METOR900M
Latest application date: 2020-05-11
FCC ID Device Details
| FCC ID | 2AVRB-METOR-900M |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AVRB |
| Product Code | METOR900M |
| Applicant Business | Rapiscan Systems 🇺🇸 |
| Related Domains | |
| Equipment Class | Metor 900M Walk-Through Metal Detector |
| Test Firm | SGS Fimko Oy |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 13.56 MHz | Original Equipment | 2020-05-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2020-11-07 | PDF 984 KB |
| Internal Photos | Internal Photos | 2020-11-07 | PDF 1.1 MB |
| External Photos | External Photos | 2020-11-07 | PDF 254.2 KB |
| Label Info | ID Label/Location Info | 2020-05-11 | PDF 49.3 KB |
| Label Location | ID Label/Location Info | 2020-05-11 | PDF 99.4 KB |
| Test Setup Photos | Test Setup Photos | 2020-11-07 | PDF 513.8 KB |
| RF Test Report | Test Report | 2020-05-11 | PDF 716 KB |
| Confidentiality Report | Cover Letter(s) | 2020-05-11 | PDF 105.6 KB |
| RF Exposure Assessment | RF Exposure Info | 2020-05-11 | PDF 203.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 176.5 KB | |
| Schematics Metadata only | Schematics | PDF 52.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 222.2 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 28 KB |
Application Information
| Application ID | ql6czUjmcRxiTqwIZsrk9w== |
|---|---|
| Final Action Date | 2020-05-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0029248879 |
| Model | METOR-900M |
| Frequency Range | 13.56 MHz |
| Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter |
| Device Description | Metor 900M Walk-Through Metal Detector |
| Responsible Party | Ankur Mohindru, amohindru@rapiscansystems.com |
| Technical Contact | Ankur Mohindru, Rapiscan Systems Inc, amohindru@rapiscansystems.com |
| Non-Technical Contact | Ankur Mohindru, Rapiscan Systems Inc, amohindru@rapiscansystems.com |
| Test Firm | Janne Nyman, SGS Fimko Oy, janne.nyman@sgs.eom |
| TCB Email | uscts.tcb@sgs.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 11/07/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ql6czUjmcRxiTqwIZsrk9w== | 2020-05-11 | Original Equipment |
Equipment Authorization
| Frequency | Rules |
|---|---|
| 13.56 MHz | 15C |
Grants
TCB Grant - Application ql6czUjmcRxiTqwIZsrk9w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 05/11/2020 Application Dated: 05/11/2020 |
| Rapiscan Systems |
| 2805 Columbia Street |
| Torrance, CA 90503 |
| Attention: Ankur Mohindru |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVRB-METOR-900M |
| Name of Grantee: | Rapiscan Systems |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Metor 900M Walk-Through Metal Detector |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 13.56 - 13.56 |
EAS Grant - Application ql6czUjmcRxiTqwIZsrk9w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Rapiscan Systems 2805 Columbia Street Torrance, CA 90503 United States |
Date of Grant: 05/11/2020 Application Dated: 05/11/2020 |
| Attention: Ankur Mohindru |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVRB-METOR-900M |
| Name of Grantee: | Rapiscan Systems |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Metor 900M Walk-Through Metal Detector |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 13.56 - 13.56 |
| Mail To: |