FCC ID 2AVVM-MAC7
MAC7
by GE Medical Systems Information Technologies, Inc.
Grantee Code: 2AVVM Product Code: MAC7
Latest application date: 2020-03-31
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: OU5-MAC7 Grant Date: 02/13/2019 | 2020-03-31 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: OU5-MAC7 Grant Date: 02/13/2019 | 2020-03-31 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2020-03-31 | PDF 312.5 KB |
| Label and Label location | ID Label/Location Info | 2020-03-31 | PDF 97.2 KB |
| Cover letter_change FCC ID of new grantee | Attestation Statements | 2020-03-31 | PDF 22.4 KB |
| OU5 to 2AVVM FCC ID Change of original grantee | Attestation Statements | 2020-03-31 | PDF 15.5 KB |
| FCC Authority | Cover Letter(s) | 2020-03-31 | PDF 27.4 KB |
Application Information
| Application ID | wV2IRk/tprWTjfX5Vr18vg== |
|---|---|
| Final Action Date | 2020-03-31 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: OU5-MAC7 Grant Date: 02/13/2019 |
| Applicant FRN | 0029314614 |
| Model | MAC7 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | MAC7 |
| Responsible Party | honghong Yang, Honghong.Yang@ge.com |
| Technical Contact | Nemo Li, Intertek Testing Services Limited Shanghai, nemo.li@intertek.com |
| Test Firm | Leah Xu, Intertek Testing Services Shanghai, leah.xu@intertek.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. Device is a 802.11 b/g/n device in a 2x2 Spatial Multiplexing MIMO configuration and enabled only for 802.11n HT20 as described in this filing. The device has been certified for mobile use and any co-location must be done through the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 5G WLAN transmitter. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wV2IRk/tprWTjfX5Vr18vg== | 2020-03-31 | Change in identification of presently authorized equipment. Original FCC ID: OU5-MAC7 Grant Date: 02/13/2019 |
| hUmyP7QHm4yGKVIJoCZ4wA== | 2020-03-31 | Change in identification of presently authorized equipment. Original FCC ID: OU5-MAC7 Grant Date: 02/13/2019 |
Equipment Authorization
Grants
TCB Grant - Application wV2IRk/tprWTjfX5Vr18vg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 03/31/2020 Application Dated: 03/25/2020 |
| GE Medical Systems Information Technologies, Inc. |
| 9900 Innovation Drive, Wauwatosa, WI 53226 USA |
| P.O. Box 53226, |
| Wauwatosa, WI 53226 |
| Attention: honghong Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVVM-MAC7 |
| Name of Grantee: | GE Medical Systems Information Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | MAC7 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.059 |
| Output power listed is conducted. Device is a 802.11 b/g/n device in a 2x2 Spatial Multiplexing MIMO configuration and enabled only for 802.11n HT20 as described in this filing. The device has been certified for mobile use and any co-location must be done through the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 5G WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application wV2IRk/tprWTjfX5Vr18vg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GE Medical Systems Information Technologies, Inc. 9900 Innovation Drive, Wauwatosa, WI 53226 USA P.O. Box 53226, Wauwatosa, WI 53226 United States |
Date of Grant: 03/31/2020 Application Dated: 03/25/2020 |
| Attention: honghong Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVVM-MAC7 |
| Name of Grantee: | GE Medical Systems Information Technologies, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | MAC7 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.059 |
| Output power listed is conducted. Device is a 802.11 b/g/n device in a 2x2 Spatial Multiplexing MIMO configuration and enabled only for 802.11n HT20 as described in this filing. The device has been certified for mobile use and any co-location must be done through the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 5G WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 03/31/2020 Application Dated: 03/25/2020 |
| GE Medical Systems Information Technologies, Inc. |
| 9900 Innovation Drive, Wauwatosa, WI 53226 USA |
| P.O. Box 53226, |
| Wauwatosa, WI 53226 |
| Attention: honghong Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVVM-MAC7 |
| Name of Grantee: | GE Medical Systems Information Technologies, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MAC7 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.022 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.027 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.034 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.022 |
| Power Output listed is conducted. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 2.4G WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application hUmyP7QHm4yGKVIJoCZ4wA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GE Medical Systems Information Technologies, Inc. 9900 Innovation Drive, Wauwatosa, WI 53226 USA P.O. Box 53226, Wauwatosa, WI 53226 United States |
Date of Grant: 03/31/2020 Application Dated: 03/25/2020 |
| Attention: honghong Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AVVM-MAC7 |
| Name of Grantee: | GE Medical Systems Information Technologies, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MAC7 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.022 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.027 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.034 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.022 |
| Power Output listed is conducted. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 2.4G WLAN transmitter. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |