FCC ID 2AW3IP805B

Smart Diagnostic System

by Shenzhen Xtooltech Intelligent Co., Ltd.

Grantee Code: 2AW3I   Product Code: P805B
Latest application date: 2026-06-29

FCC ID Device Details

FCC ID2AW3IP805B
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AW3I
Product CodeP805B
Applicant BusinessShenzhen Xtooltech Intelligent Co., Ltd. 🇨🇳
Related Domains xtooltech.com fccusagent.com
Equipment ClassSmart Diagnostic System
Test FirmSHENZHEN CTA TESTING TECHNOLOGY CO., LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/20262026-06-29
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/20262026-06-29
5745-5825 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/20262026-06-29

Exhibits

DocumentTypeAvailableFile
Label and its LocationID Label/Location Info2026-06-29PDF 215.8 KB
2.911_(d)(5)(i) Certification EquipmentAttestation Statements2026-06-29PDF 94.4 KB
2.911_(d)(5)(ii) Certificiation Applicant v1.3Attestation Statements2026-06-29PDF 91.2 KB
2.911_(d)(7) US AGENTAttestation Statements2026-06-29PDF 143.4 KB
FCC Authorization from Original Grantee for ID change V1.1Cover Letter(s)2026-06-29PDF 88.3 KB
FCC Request for change in ID Rev 2.1Cover Letter(s)2026-06-29PDF 97.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2026-06-29PDF 63.4 KB
Letter of Authorization Rev 1.0Cover Letter(s)2026-06-29PDF 65.5 KB
Model DifferenceCover Letter(s)2026-06-29PDF 69.2 KB
ExternalPhotos Metadata onlyExternal Photos2026-12-27PDF 475.1 KB

Application Information

Application IDw+J8CrKueacgOLgnxVSJnQ==
Final Action Date2026-06-29
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/2026
Applicant FRN0029799749
ModelP805B
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Diagnostic System
Responsible PartyPink Zou, liping.zou@xtooltech.com , +86-13590123521
Technical ContactShenzhen Xtooltech Intelligent Co., Ltd, liping.zou@xtooltech.com
Non-Technical ContactTim Payne, FCC US Agent, LLC, support@fccusagent.com , 07085713148
Test FirmEric Wang, SHENZHEN CTA TESTING TECHNOLOGY CO., LTD., wangxulai@cta-test.cn , 86-755-2322-5875
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
w+J8CrKueacgOLgnxVSJnQ==2026-06-29Change in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/2026
eey/CcuCcQE+Im7kYNcQZg==2026-06-29Change in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/2026
/bBnFTYiF3hCsTw8RAMxug==2026-06-29Change in identification of presently authorized equipment. Original FCC ID: 2AW3IP805A Grant Date: 01/07/2026

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.0012215CCC
2402-2480 MHz0.0015315CCC
5180-5240 MHz0.0176215ECC
5260-5320 MHz0.0161115ECC ND
5500-5700 MHz0.0166715ECC ND
5745-5825 MHz0.0163315ECC

Grants

TCB Grant - Application w+J8CrKueacgOLgnxVSJnQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2026

Application Dated: 06/29/2026
Shenzhen Xtooltech Intelligent Co., Ltd.
17&18/F, A2 Building, Creative City, Liuxian
Avenue, Nanshan District
Shenzhen, 518000
China
 
Attention: Pink Zou , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AW3IP805B
Name of Grantee:  Shenzhen Xtooltech Intelligent Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Diagnostic System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00122  

Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 0.38 W/kg and 0.62 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application eey/CcuCcQE+Im7kYNcQZg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2026

Application Dated: 06/29/2026
Shenzhen Xtooltech Intelligent Co., Ltd.
17&18/F, A2 Building, Creative City, Liuxian
Avenue, Nanshan District
Shenzhen, 518000
China
 
Attention: Pink Zou , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AW3IP805B
Name of Grantee:  Shenzhen Xtooltech Intelligent Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Diagnostic System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00153  

Power listed is the maximum conducted output power.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application /bBnFTYiF3hCsTw8RAMxug==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/29/2026

Application Dated: 06/29/2026
Shenzhen Xtooltech Intelligent Co., Ltd.
17&18/F, A2 Building, Creative City, Liuxian
Avenue, Nanshan District
Shenzhen, 518000
China
 
Attention: Pink Zou , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AW3IP805B
Name of Grantee:  Shenzhen Xtooltech Intelligent Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Smart Diagnostic System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01762  
CC ND 15E 5260.0  -  5320.0 0.01611  
CC ND 15E 5500.0  -  5700.0 0.01667  
CC 15E 5745.0  -  5825.0 0.01633  

Output power listed is maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn and simultaneous SAR accessory are 0.38 W/kg and 0.62 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).