FCC ID 2AWW4-TR2-1

Sensize Tracker v2 CAT-M

by Sensize Limited

Grantee Code: 2AWW4   Product Code: TR21
Latest application date: 2020-08-11

FCC ID Device Details

FCC ID2AWW4-TR2-1
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AWW4
Product CodeTR21
Applicant BusinessSensize Limited 🇬🇧
Related Domains sensize.net
Equipment ClassSensize Tracker v2 CAT-M
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2020-08-11
699.7-715.3 MHzOriginal Equipment2020-08-11

Exhibits

DocumentTypeAvailableFile
User_ManualUsers Manual2020-09-25PDF 3.1 MB
Internal PhotosInternal Photos2020-09-25PDF 2.3 MB
Ext_PhotosExternal Photos2020-09-25PDF 1.8 MB
External_PhotosExternal Photos2020-09-25PDF 1.8 MB
Label and Label_LocationID Label/Location Info2020-08-11PDF 140.1 KB
Label_locationID Label/Location Info2020-08-11PDF 140.1 KB
Test_Setup_PhotosTest Setup Photos2020-09-25PDF 341.2 KB
Test_Setup_PhotosTest Setup Photos2020-09-25PDF 306.9 KB
S20060204002001-BLETest Report2020-08-11PDF 2 MB
S20060204002002-2.4G WIFI - Part 1Test Report2020-08-11PDF 3.3 MB
S20060204002002-2.4G WIFI - Part 2Test Report2020-08-11PDF 3.3 MB
S20060204002003-2GTest Report2020-08-11PDF 460.7 KB
S20060204002004-4GTest Report2020-08-11PDF 709.5 KB
SDoC Attestation LetterCover Letter(s)2020-08-11PDF 445.9 KB
Agent_AuthorizationCover Letter(s)2020-08-11PDF 64.4 KB
FCC_Long_Term_Only_ConfidentialityCover Letter(s)2020-08-11PDF 71.6 KB
FCC_Long_Term_Only_Confidentiality_RequestCover Letter(s)2020-08-11PDF 71.6 KB
family models declaration letterCover Letter(s)2020-08-11PDF 142.9 KB
RF_ExposureRF Exposure Info2020-08-11PDF 233.8 KB
RF_exposure_reportRF Exposure Info2020-08-11PDF 233.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 195.7 KB
SCH Metadata onlySchematicsPDF 869.3 KB
Operational_Description Metadata onlyOperational DescriptionPDF 270.5 KB
operation_description Metadata onlyOperational DescriptionPDF 270.5 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 12.5 KB
Tune up procedure (1) Metadata onlyParts List/Tune Up InfoPDF 252.1 KB

Application Information

Application IDy1vanHdrU9dgdfMMwtTEhA==
Final Action Date2020-08-11
Application PurposeOriginal Equipment
Applicant FRN0029770211
ModelTR2-1
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSensize Tracker v2 CAT-M
Responsible PartyLuke DArcy, luke.darcy@sensize.net , +44 754 245 1421
Technical ContactSensize Limited, luke.darcy@sensize.net
Test FirmAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn , +86-755-6115-9384
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/25/2020
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
y1vanHdrU9dgdfMMwtTEhA==2020-08-11Original Equipment
LlQ8YbcxIf5UuRQfH+u7HA==2020-08-11Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
699.7-715.3 MHz0.2212.5ppm1M10W7D27
699.7-715.3 MHz0.2562.5ppm1M10G7D27
778.24-785.8 MHz0.2382.5ppm1M19G7D27
778.24-785.8 MHz0.2482.5ppm1M20W7D27
1710.7-1754.3 MHz0.1912.19ppm1M11W7D27
1710.7-1754.3 MHz0.222.19ppm1M10G7D27
1850.2-1909.8 MHz0.7741.06ppm244KGXW24E
1850.7-1909.3 MHz0.2241.76ppm1M11W7D24E
1850.7-1909.3 MHz0.2621.76ppm1M10G7D24E
2402-2480 MHz0.00440815C
2412-2462 MHz0.01954315C

Grants

TCB Grant - Application y1vanHdrU9dgdfMMwtTEhA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/11/2020

Application Dated: 08/11/2020
Sensize Limited
Sensize, Future Business Centre,
Kings Hedges Road,CambridgeCB4 2HY, UK
Cambridge,
United Kingdom
 
Attention: Luke DArcy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AWW4-TR2-1
Name of Grantee:  Sensize Limited
Equipment Class: Digital Transmission System
Notes: Sensize Tracker v2 CAT-M
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.004408  
15C 2412.0  -  2462.0 0.019543  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application y1vanHdrU9dgdfMMwtTEhA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensize Limited
Sensize, Future Business Centre, Kings Hedges Road,CambridgeCB4 2HY, UK
Cambridge,
United Kingdom
  Date of Grant: 08/11/2020

Application Dated: 08/11/2020
 
Attention: Luke DArcy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AWW4-TR2-1
Name of Grantee:  Sensize Limited
Equipment Class: Digital Transmission System
Notes: Sensize Tracker v2 CAT-M
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.004408  
15C 2412.0  -  2462.0 0.019543  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



TCB Grant - Application LlQ8YbcxIf5UuRQfH+u7HA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/11/2020

Application Dated: 08/11/2020
Sensize Limited
Sensize, Future Business Centre,
Kings Hedges Road,CambridgeCB4 2HY, UK
Cambridge,
United Kingdom
 
Attention: Luke DArcy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AWW4-TR2-1
Name of Grantee:  Sensize Limited
Equipment Class: PCS Licensed Transmitter
Notes: Sensize Tracker v2 CAT-M
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.614 1.79  PM 244KGXW
24E 1850.2  -  1909.8 0.774 1.06  PM 244KGXW
24E 1850.7  -  1909.3 0.224 1.76  PM 1M11W7D
24E 1850.7  -  1909.3 0.262 1.76  PM 1M10G7D
27 1710.7  -  1754.3 0.191 2.19  PM 1M11W7D
27 1710.7  -  1754.3 0.22 2.19  PM 1M10G7D
27 699.7  -  715.3 0.221 2.5  PM 1M10W7D
27 699.7  -  715.3 0.256 2.5  PM 1M10G7D
27 778.24  -  785.8 0.248 2.5  PM 1M20W7D
27 778.24  -  785.8 0.238 2.5  PM 1M19G7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application LlQ8YbcxIf5UuRQfH+u7HA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensize Limited
Sensize, Future Business Centre, Kings Hedges Road,CambridgeCB4 2HY, UK
Cambridge,
United Kingdom
  Date of Grant: 08/11/2020

Application Dated: 08/11/2020
 
Attention: Luke DArcy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AWW4-TR2-1
Name of Grantee:  Sensize Limited
Equipment Class: PCS Licensed Transmitter
Notes: Sensize Tracker v2 CAT-M
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.614 1.79  PM 244KGXW
24E 1850.2  -  1909.8 0.774 1.06  PM 244KGXW
24E 1850.7  -  1909.3 0.224 1.76  PM 1M11W7D
24E 1850.7  -  1909.3 0.262 1.76  PM 1M10G7D
27 1710.7  -  1754.3 0.191 2.19  PM 1M11W7D
27 1710.7  -  1754.3 0.22 2.19  PM 1M10G7D
27 699.7  -  715.3 0.221 2.5  PM 1M10W7D
27 699.7  -  715.3 0.256 2.5  PM 1M10G7D
27 778.24  -  785.8 0.248 2.5  PM 1M20W7D
27 778.24  -  785.8 0.238 2.5  PM 1M19G7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: