FCC ID 2AX52-LRSM0005

IoT Wearable Device

by QIKCONNEX D/B/A HAE INNOVATIONS

Grantee Code: 2AX52   Product Code: LRSM0005
Latest application date: 2021-07-23

FCC ID Device Details

FCC ID2AX52-LRSM0005
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AX52
Product CodeLRSM0005
Applicant BusinessQIKCONNEX D/B/A HAE INNOVATIONS 🇺🇸
Related Domains haeinnovations.com
Equipment ClassIoT Wearable Device
Test FirmIntertek Testing Services NA

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
777.2-786.8 MHzOriginal Equipment2021-07-23
2402-2480 MHzOriginal Equipment2021-07-23

Exhibits

DocumentTypeAvailableFile
MANUALUsers Manual2021-07-23PDF 381.3 KB
INTERNAL PHOTOSInternal Photos2021-07-23PDF 150 KB
EXTERNAL PHOTOSExternal Photos2021-07-23PDF 96.1 KB
LABEL AND LOCATIONID Label/Location Info2021-07-23PDF 51.5 KB
SAR TEST SETUP PHOTOSTest Setup Photos2021-07-23PDF 344.5 KB
TEST SETUP PHOTOSTest Setup Photos2021-07-23PDF 1.1 MB
SAR TEST REPORTRF Exposure Info2021-07-23PDF 1 MB
TEST REPORTTest Report2021-07-23PDF 1 MB
TEST REPORTTest Report2021-07-23PDF 1.4 MB
CONFIDENTIALITY REQUESTCover Letter(s)2021-07-23PDF 88.8 KB
LETTER OF AGENCYCover Letter(s)2021-07-23PDF 44.1 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 103.2 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 110.4 KB
SCHEMATICS Metadata onlySchematicsPDF 334.6 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 187.3 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 618.5 KB
PARTS LIST Metadata onlyParts List/Tune Up InfoPDF 595.4 KB
TUNE UP PROCEDURE Metadata onlyParts List/Tune Up InfoPDF 662.2 KB

Application Information

Application IDZt7pmnNcU1i8Gzo/AvGhMA==
Final Action Date2021-07-23
Application PurposeOriginal Equipment
Applicant FRN0030178586
ModelLRSM0005
Frequency Range777.2-786.8 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionIoT Wearable Device
Responsible PartyHesham ElHamahmy, hesham@haeinnovations.com , 17322459447
Technical ContactRanjeet Singh, QIKCONNEX D/B/A HAE INNOVATIONS, ranjeet@haeinnovations.com , 6462045138
Non-Technical ContactHesham ElHamahmy, QIKCONNEX D/B/A HAE INNOVATIONS, hesham@haeinnovations.com , 7322459447
Test FirmJames Sudduth, Intertek Testing Services NA, james.sudduth@intertek.com , 859-226-1037
TCB Emailtcb_admin@intertek.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is conducted. SAR compliance for body worn operating conditions is limited to the specific accessory tested with product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR value for body-worn accessory, product specific use condition is 0.044 W/kg.

Applications

Application IDDatePurpose
Zt7pmnNcU1i8Gzo/AvGhMA==2021-07-23Original Equipment
/xbFx1YWji3sODC4Z84HbQ==2021-07-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
777.2-786.8 MHz0.12400000.0217000000ppm1M30G7D27
2402-2480 MHz0.000660015C

Grants

TCB Grant - Application Zt7pmnNcU1i8Gzo/AvGhMA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 07/23/2021

Application Dated: 07/23/2021
QIKCONNEX D/B/A HAE INNOVATIONS
14 CULNEN DR
LOWER LEVEL
BRANCHBURG, NJ 08876
 
Attention: Hesham ElHamahmy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX52-LRSM0005
Name of Grantee:  QIKCONNEX D/B/A HAE INNOVATIONS
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: IoT Wearable Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 777.2  -  786.8 0.124 0.0217  PM 1M30G7D

Output Power listed is conducted. SAR compliance for body worn operating conditions is limited to the specific accessory tested with product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR value for body-worn accessory, product specific use condition is 0.044 W/kg.

EAS Grant - Application Zt7pmnNcU1i8Gzo/AvGhMA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

QIKCONNEX D/B/A HAE INNOVATIONS
14 CULNEN DR LOWER LEVEL
BRANCHBURG, NJ 08876
United States
  Date of Grant: 07/23/2021

Application Dated: 07/23/2021
 
Attention: Hesham ElHamahmy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX52-LRSM0005
Name of Grantee:  QIKCONNEX D/B/A HAE INNOVATIONS
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: IoT Wearable Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 777.2  -  786.8 0.124 0.0217  PM 1M30G7D

Output Power listed is conducted. SAR compliance for body worn operating conditions is limited to the specific accessory tested with product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR value for body-worn accessory, product specific use condition is 0.044 W/kg.



TCB Grant - Application /xbFx1YWji3sODC4Z84HbQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 07/23/2021

Application Dated: 07/23/2021
QIKCONNEX D/B/A HAE INNOVATIONS
14 CULNEN DR
LOWER LEVEL
BRANCHBURG, NJ 08876
 
Attention: Hesham ElHamahmy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX52-LRSM0005
Name of Grantee:  QIKCONNEX D/B/A HAE INNOVATIONS
Equipment Class: Digital Transmission System
Notes: IoT Wearable Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00066  

Output Power listed is conducted. SAR compliance for body worn operating conditions is limited to the specific accessory tested with product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR value for body-worn accessory, product specific use condition is 0.044 W/kg.

EAS Grant - Application /xbFx1YWji3sODC4Z84HbQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

QIKCONNEX D/B/A HAE INNOVATIONS
14 CULNEN DR LOWER LEVEL
BRANCHBURG, NJ 08876
United States
  Date of Grant: 07/23/2021

Application Dated: 07/23/2021
 
Attention: Hesham ElHamahmy

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX52-LRSM0005
Name of Grantee:  QIKCONNEX D/B/A HAE INNOVATIONS
Equipment Class: Digital Transmission System
Notes: IoT Wearable Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00066  

Output Power listed is conducted. SAR compliance for body worn operating conditions is limited to the specific accessory tested with product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR value for body-worn accessory, product specific use condition is 0.044 W/kg.