FCC ID 2AX57OV2219

Arm-mounted Tablet

by Oneview Healthcare Inc

Grantee Code: 2AX57   Product Code: OV2219
Latest application date: 2021-02-08

FCC ID Device Details

FCC ID2AX57OV2219
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AX57
Product CodeOV2219
Applicant BusinessOneview Healthcare Inc 🇮🇪
Related Domains oneviewhealthcare.com uttlab.com
Equipment ClassArm-mounted Tablet
Test FirmShenzhen UnionTrust Quality and Technology Co., Lt

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
13.56 MHzOriginal Equipment2021-02-08
0.125 MHzOriginal Equipment2021-02-08
2402-2480 MHzOriginal Equipment2021-02-08
5180-5240 MHzOriginal Equipment2021-02-08
2402-2480 MHzOriginal Equipment2021-02-08

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2021-02-08PDF 1.6 MB
Internal photosInternal Photos2021-02-08PDF 4.5 MB
External photosExternal Photos2021-02-08PDF 1.7 MB
ID label and locationID Label/Location Info2021-02-08PDF 151.9 KB
Test setup photosTest Setup Photos2021-02-08PDF 853.3 KB
Test setup photosTest Setup Photos2021-02-08PDF 658.3 KB
Test setup photosTest Setup Photos2021-02-08PDF 482.8 KB
Test reportsTest Report2021-02-08PDF 4.8 MB
Test reports Metadata onlyCover Letter(s)2021-02-08PDF 4.8 MB
Test reportsTest Report2021-02-08PDF 4.5 MB
Test reportsTest Report2021-02-08PDF 5.6 MB
Test reportsTest Report2021-02-08PDF 4.7 MB
Test reportsTest Report2021-02-08PDF 2.4 MB
Test reportsTest Report2021-02-08PDF 2.5 MB
Test reportsTest Report2021-02-08PDF 2.4 MB
ConfidentialityCover Letter(s)2021-02-08PDF 143.4 KB
Letter AuthorizationCover Letter(s)2021-02-08PDF 143.3 KB
Software_Configuration_ControlCover Letter(s)2021-02-08PDF 141.8 KB
RF ExposureRF Exposure Info2021-02-08PDF 1.8 MB
Block Diagram Metadata onlyBlock DiagramPDF 219 KB
Schematics Metadata onlySchematicsPDF 1.1 MB
Operational Description Metadata onlyOperational DescriptionPDF 672.5 KB
Security Info. Metadata onlySDR Software/Security InfPDF 328.1 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 262.9 KB

Application Information

Application IDziWIa9yE3eIMC/4y+I6uLw==
Final Action Date2021-02-08
Application PurposeOriginal Equipment
Applicant FRN0030057004
ModelOV2219
Frequency Range13.56 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionArm-mounted Tablet
Responsible PartyJP Howe, Director of Engineering, jphowe@oneviewhealthcare.com , 353868578850
Technical ContactBilly li, Shenzhen UnionTrust Quality and Technology Co., Lt, billy.li@uttlab.com , 0755-28230888
Non-Technical ContactBilly li, Shenzhen UnionTrust Quality and Technology Co., Lt, billy.li@uttlab.com , 0755-28230888
Test FirmGeorge Luo, Shenzhen UnionTrust Quality and Technology Co., Lt, quality@uttlab.com , +86-755-28230888
TCB Emailelabscert@applus.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
ziWIa9yE3eIMC/4y+I6uLw==2021-02-08Original Equipment
fi20/IWKQ7z8rcmFbhdREQ==2021-02-08Original Equipment
et2W+AMfU9paZTPsiInnYw==2021-02-08Original Equipment
Qbe72wIyA8jWReztSE9hYQ==2021-02-08Original Equipment
McmCS7s5JgOOYhoaUF1gKQ==2021-02-08Original Equipment
5Y/mxpozIzFsMq+8jMrlMg==2021-02-08Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
0.125 MHz15CCC
13.56 MHz15CCC
2402-2480 MHz0.004220015CCC
2402-2480 MHz0.0048915CCC
2412-2462 MHz0.2985415CCC
5180-5240 MHz0.0374115E38, CC
5260-5320 MHz0.0357315E38, CC, ND
5500-5700 MHz0.036915E38, CC, ND
5745-5825 MHz0.020815E38, CC

Grants

TCB Grant - Application ziWIa9yE3eIMC/4y+I6uLw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ziWIa9yE3eIMC/4y+I6uLw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Qbe72wIyA8jWReztSE9hYQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Digital Transmission System
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00489  
CC 15C 2412.0  -  2462.0 0.29854  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application Qbe72wIyA8jWReztSE9hYQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Digital Transmission System
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00489  
CC 15C 2412.0  -  2462.0 0.29854  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application McmCS7s5JgOOYhoaUF1gKQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.03741  
38 CC ND 15E 5260.0  -  5320.0 0.03573  
38 CC ND 15E 5500.0  -  5700.0 0.0369  
38 CC 15E 5745.0  -  5825.0 0.0208  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.The device contains 20MHz, 40MHz and 80MHz bandwidth.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application McmCS7s5JgOOYhoaUF1gKQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.03741  
38 CC ND 15E 5260.0  -  5320.0 0.03573  
38 CC ND 15E 5500.0  -  5700.0 0.0369  
38 CC 15E 5745.0  -  5825.0 0.0208  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.The device contains 20MHz, 40MHz and 80MHz bandwidth.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application fi20/IWKQ7z8rcmFbhdREQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application fi20/IWKQ7z8rcmFbhdREQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application et2W+AMfU9paZTPsiInnYw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Low Power Transmitter Below 1705 kHz
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 0.125  -  0.125  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application et2W+AMfU9paZTPsiInnYw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Low Power Transmitter Below 1705 kHz
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 0.125  -  0.125  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 5Y/mxpozIzFsMq+8jMrlMg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 02/08/2021

Application Dated: 02/08/2021
Oneview Healthcare Inc
Block 2, Blackrock Business Park
Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Arm-mounted Tablet
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00422  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 5Y/mxpozIzFsMq+8jMrlMg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Oneview Healthcare Inc
Block 2, Blackrock Business Park Blackrock, Co. DublinP.O. Box A94 H2X4,
Blackrock,
Ireland
  Date of Grant: 02/08/2021

Application Dated: 02/08/2021
 
Attention: JP Howe , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AX57OV2219
Name of Grantee:  Oneview Healthcare Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Arm-mounted Tablet
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00422  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: