FCC ID 2AX5J-RAP73HD
Wireless Access Point
by Ruijie Networks Co., Ltd.
Grantee Code: 2AX5J Product Code: RAP73HD
Latest application date: 2023-08-02
FCC ID Device Details
| FCC ID | 2AX5J-RAP73HD |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AX5J |
| Product Code | RAP73HD |
| Applicant Business | Ruijie Networks Co., Ltd. 🇨🇳 |
| Related Domains | |
| Equipment Class | Wireless Access Point |
| Test Firm | Dongguan Dongdian Testing Service Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2023-08-02 |
| 5180-5240 MHz | Original Equipment | 2023-08-02 |
| 5955-7115 MHz | Original Equipment | 2023-08-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2024-01-14 | PDF 1 MB |
| User manual-2 | Users Manual | 2024-01-14 | PDF 1.2 MB |
| User manual-S | Users Manual | 2024-01-14 | PDF 1.2 MB |
| Internal photos | Internal Photos | 2024-01-14 | PDF 2.3 MB |
| External photos | External Photos | 2024-01-14 | PDF 2.4 MB |
| ID label and location | ID Label/Location Info | 2023-08-02 | PDF 209.1 KB |
| Test setup photos | Test Setup Photos | 2024-01-14 | PDF 662.4 KB |
| Antenna specifications | Test Report | 2023-08-02 | PDF 5.5 MB |
| DDT-RE23032214-2E03 RG-RAP73HD FCC ID&ISED Report Master DFS | Test Report | 2023-08-02 | PDF 2.2 MB |
| Test reports-1 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-1 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-1 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-10 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-10 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-10 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-11 | Test Report | 2023-08-02 | PDF 2.1 MB |
| Test reports-11 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-11 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-12 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-12 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-13 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-13 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-14 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-14 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-15 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-15 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-16 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-16 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-17 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-17 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-18 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-18 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-19 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-19 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-2 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-2 | Test Report | 2023-08-02 | PDF 5.2 MB |
| Test reports-2 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-20 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-20 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-21 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-21 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-22 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-23 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-23 | Test Report | 2023-08-02 | PDF 5.9 MB |
| Test reports-24 | Test Report | 2023-08-02 | PDF 5.6 MB |
| Test reports-24 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-25 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-25 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-26 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-26 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-27 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-27 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-28 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-28 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-29 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-29 | Test Report | 2023-08-02 | PDF 3.2 MB |
| Test reports-3 | Test Report | 2023-08-02 | PDF 5.2 MB |
| Test reports-3 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-3 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-30 | Test Report | 2023-08-02 | PDF 2.3 MB |
| Test reports-30 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-31 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-31 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-32 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-32 | Test Report | 2023-08-02 | PDF 5.7 MB |
| Test reports-33 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-33 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-34 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-34 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-35 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-35 | Test Report | 2023-08-02 | PDF 3.9 MB |
| Test reports-36 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-37 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-38 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-39 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-4 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-4 | Test Report | 2023-08-02 | PDF 5.2 MB |
| Test reports-4 | Test Report | 2023-08-02 | PDF 5.2 MB |
| Test reports-40 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-41 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-42 | Test Report | 2023-08-02 | PDF 640.6 KB |
| Test reports-5 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-5 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-5 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-6 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-6 | Test Report | 2023-08-02 | PDF 5.2 MB |
| Test reports-6 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-7 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-7 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Test reports-7 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-8 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-8 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-8 | Test Report | 2023-08-02 | PDF 5.4 MB |
| Test reports-9 | Test Report | 2023-08-02 | PDF 5.6 MB |
| Test reports-9 | Test Report | 2023-08-02 | PDF 5.3 MB |
| Test reports-9 | Test Report | 2023-08-02 | PDF 5.5 MB |
| Attestation Statements | Attestation Statements | 2023-08-02 | PDF 127.3 KB |
| US Agent Letter | Attestation Statements | 2023-08-02 | PDF 129.7 KB |
| Agent letter | Cover Letter(s) | 2023-08-02 | PDF 22.5 KB |
| Confidentiality | Cover Letter(s) | 2023-08-02 | PDF 69.4 KB |
| Letter Authorization | Cover Letter(s) | 2023-08-02 | PDF 57.2 KB |
| RF Exposure | RF Exposure Info | 2023-08-02 | PDF 776.2 KB |
| Block Diagram Metadata only | Block Diagram | PDF 614.6 KB | |
| Schematics Metadata only | Schematics | PDF 1.7 MB | |
| Operational Description Metadata only | Operational Description | PDF 268.3 KB | |
| Security Info. Metadata only | SDR Software/Security Inf | PDF 100.7 KB |
Application Information
| Application ID | yt6/2DIr1Lvt1Yj9A84uTA== |
|---|---|
| Final Action Date | 2023-08-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030175251 |
| Model | RAP73HD |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wireless Access Point |
| Responsible Party | Chao Jiang, Manager, jiangchao@ruijie.com.cn |
| Agent | Damon Damon Damon, Dongguan Dongdian Testing Service Co., Ltd |
| Technical Contact | Damon Hu, Dongguan Dongdian Testing Service Co., Ltd, Damon_Hu@dgddt.com |
| Non-Technical Contact | Damon Hu, Dongguan Dongdian Testing Service Co., Ltd, Damon_Hu@dgddt.com |
| Test Firm | Mr. Jamy Yu, Dongguan Dongdian Testing Service Co., Ltd., jamy@dgddt.com |
| TCB Email | elabscert@applus.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/14/2024 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. Device is a 4x5 MIMO as is described in the filing.The antenna(s) used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| yt6/2DIr1Lvt1Yj9A84uTA== | 2023-08-02 | Original Equipment |
| pLwTH9swiRDKKxfTqpA+4Q== | 2023-08-02 | Original Equipment |
| mm311UV3nMvqAImdtPseXA== | 2023-08-02 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application yt6/2DIr1Lvt1Yj9A84uTA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Ruijie Networks Co., Ltd. |
| Building 19, Juyuanzhou Industrial Park, |
| No. 618 Jinshan Road, Cangshan District |
| Fuzhou, Fujian, 350002 China |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.0327 |
| Output power listed is conducted. Device is a 4x5 MIMO as is described in the filing.The antenna(s) used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application yt6/2DIr1Lvt1Yj9A84uTA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ruijie Networks Co., Ltd. Building 19, Juyuanzhou Industrial Park, No. 618 Jinshan Road, Cangshan District Fuzhou, Fujian, 350002 China |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.0327 |
| Output power listed is conducted. Device is a 4x5 MIMO as is described in the filing.The antenna(s) used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Ruijie Networks Co., Ltd. |
| Building 19, Juyuanzhou Industrial Park, |
| No. 618 Jinshan Road, Cangshan District |
| Fuzhou, Fujian, 350002 China |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.0227 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.0495 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.047 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.1837 |
| Output power listed is conducted.Device is a 4x4 MIMO master Indoor AP configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz, 40MHz, 80MHz and 160MHz. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application pLwTH9swiRDKKxfTqpA+4Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ruijie Networks Co., Ltd. Building 19, Juyuanzhou Industrial Park, No. 618 Jinshan Road, Cangshan District Fuzhou, Fujian, 350002 China |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.0227 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.0495 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.047 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.1837 |
| Output power listed is conducted.Device is a 4x4 MIMO master Indoor AP configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz, 40MHz, 80MHz and 160MHz. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Ruijie Networks Co., Ltd. |
| Building 19, Juyuanzhou Industrial Park, |
| No. 618 Jinshan Road, Cangshan District |
| Fuzhou, Fujian, 350002 China |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Access Point |
| Notes: | Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7115.0 | 0.3296 |
| Power listed is maximum EIRP. Device is a 4 x 5 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80, 160 and 320 MHz bandwidth modes. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application mm311UV3nMvqAImdtPseXA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ruijie Networks Co., Ltd. Building 19, Juyuanzhou Industrial Park, No. 618 Jinshan Road, Cangshan District Fuzhou, Fujian, 350002 China |
Date of Grant: 08/02/2023 Application Dated: 07/17/2023 |
| Attention: Chao Jiang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AX5J-RAP73HD |
| Name of Grantee: | Ruijie Networks Co., Ltd. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Access Point |
| Notes: | Wireless Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7115.0 | 0.3296 |
| Power listed is maximum EIRP. Device is a 4 x 5 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80, 160 and 320 MHz bandwidth modes. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |