FCC ID 2AXJ4T310
Tapo Smart Temperature & Humidity Sensor
by TP-Link Corporation Limited
Grantee Code: 2AXJ4 Product Code: T310
Latest application date: 2022-10-11
FCC ID Device Details
| FCC ID | 2AXJ4T310 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AXJ4 |
| Product Code | T310 |
| Applicant Business | TP-Link Corporation Limited |
| Related Domains | |
| Equipment Class | Tapo Smart Temperature & Humidity Sensor |
| Test Firm | Underwriters Laboratories Taiwan Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 920.9-922.3 MHz | Original Equipment | 2022-10-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2022-10-11 | PDF 745 KB |
| 13_Internal Photos_2AXJ4T310 | Internal Photos | 2022-10-11 | PDF 1.8 MB |
| 12_External Photos_2AXJ4T310 | External Photos | 2022-10-11 | PDF 994.5 KB |
| 04_Label Location_2AXJ4T310 | ID Label/Location Info | 2022-10-11 | PDF 1.2 MB |
| 10_Setup photos_2AXJ4T310 | Test Setup Photos | 2022-10-11 | PDF 602.9 KB |
| 09_Antenna Specification_2AXJ4T310 | Test Report | 2022-10-11 | PDF 487.5 KB |
| 11_Test report_15.247 Sub-G_2AXJ4T310 | Test Report | 2022-10-11 | PDF 1.6 MB |
| 14_MPE test report_FCC MPE_2AXJ4T310 | RF Exposure Info | 2022-10-11 | PDF 260.7 KB |
| 02_Agency Letter_2AXJ4T310 | Cover Letter(s) | 2022-10-11 | PDF 127.4 KB |
| 03_Confidentiality Letter_2AXJ4T310 | Cover Letter(s) | 2022-10-11 | PDF 257.2 KB |
| Confidential_06_Block diagram_2AXJ4T310 Metadata only | Block Diagram | PDF 82.1 KB | |
| Confidential_07_Schematics_2AXJ4T310 Metadata only | Schematics | PDF 301.3 KB | |
| 08_Operational Description_2AXJ4T310 Metadata only | Operational Description | PDF 275 KB |
Application Information
| Application ID | r34zmtqvQOMlIPbO9rP+pQ== |
|---|---|
| Final Action Date | 2022-10-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0029962685 |
| Model | T310 |
| Frequency Range | 920.9-922.3 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Tapo Smart Temperature & Humidity Sensor |
| Responsible Party | Sarah Wang, certification@tp-link.com |
| Technical Contact | Eric Lee, Underwriters Laboratories Taiwan Co., Ltd., Sally.Lu@ul.com |
| Non-Technical Contact | Sally Lu, Underwriters Laboratories Taiwan Co., Ltd., Sally.Lu@ul.com |
| Test Firm | Roy Chen, Underwriters Laboratories Taiwan Co., Ltd., Roy.Chen@ul.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| r34zmtqvQOMlIPbO9rP+pQ== | 2022-10-11 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 920.9-922.3 MHz | 0.0100000 | 15C |
Grants
TCB Grant - Application r34zmtqvQOMlIPbO9rP+pQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 10/11/2022 Application Dated: 09/28/2022 |
| TP-Link Corporation Limited |
| Room 901, 9/F. , New East Ocean Centre, |
| 9 Science Museum Road, Tsim Sha Tsui, Kowloon |
| Hong Kong, Hong Kong |
| Attention: Sarah Wang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXJ4T310 |
| Name of Grantee: | TP-Link Corporation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Tapo Smart Temperature & Humidity Sensor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 920.9 - 922.3 | 0.01 |
| Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application r34zmtqvQOMlIPbO9rP+pQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TP-Link Corporation Limited Room 901, 9/F. , New East Ocean Centre, 9 Science Museum Road, Tsim Sha Tsui, Kowloon Hong Kong, Hong Kong |
Date of Grant: 10/11/2022 Application Dated: 09/28/2022 |
| Attention: Sarah Wang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXJ4T310 |
| Name of Grantee: | TP-Link Corporation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Tapo Smart Temperature & Humidity Sensor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 920.9 - 922.3 | 0.01 |
| Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |