FCC ID 2AXSZ5GMNN261

Verizon Auto-Certification Platform - 5G MM 28GHz

by Amantya Technologies, Inc

Grantee Code: 2AXSZ   Product Code: 5GMNN261
Latest application date: 2021-07-13

FCC ID Device Details

FCC ID2AXSZ5GMNN261
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AXSZ
Product Code5GMNN261
Applicant BusinessAmantya Technologies, Inc 🇺🇸
Related Domains amantyatech.com
Equipment ClassVerizon Auto-Certification Platform - 5G MM 28GHz
Test FirmSPORTON International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
27550.08-28299.96 MHzOriginal Equipment2021-07-13

Exhibits

DocumentTypeAvailableFile
MFQ001_User ManualUsers Manual2021-07-13PDF 1.1 MB
MFQ001_User Manual-UpdatedUsers Manual2021-07-13PDF 1.1 MB
MFQ001_InPho_Part1Internal Photos2021-07-13PDF 5.8 MB
MFQ001_InPho_Part2Internal Photos2021-07-13PDF 4.5 MB
MFQ001_ExPhoExternal Photos2021-07-13PDF 1.6 MB
MFQ001_LabelID Label/Location Info2021-07-13PDF 106 KB
MFQ001_Label LocationID Label/Location Info2021-07-13PDF 139.1 KB
MFQ001_Tsup_Part 30Test Setup Photos2021-07-13PDF 551.5 KB
MFQ001_TestRpt_Part 30_Part1Test Report2021-07-13PDF 5 MB
MFQ001_TestRpt_Part 30_Part2Test Report2021-07-13PDF 3.8 MB
MFQ001_cvrltr_FCC Confidentiality RequestCover Letter(s)2021-07-13PDF 239.9 KB
MFQ001_cvrltr_FCC POACover Letter(s)2021-07-13PDF 254.3 KB
MFQ001_TestRFxp_MPERF Exposure Info2021-07-13PDF 395.9 KB
MFQ001_TestRFxp_MPE-UpdatedRF Exposure Info2021-07-13PDF 393 KB
MFQ001_BlckDic Metadata onlyBlock DiagramPDF 252.2 KB
MFQ001_Tune up Metadata onlySchematicsPDF 2.5 MB
MFQ001_OpDes Metadata onlyOperational DescriptionPDF 279.9 KB
MFQ001_PartsLst Metadata onlyParts List/Tune Up InfoPDF 150.2 KB

Application Information

Application IDC+Vf7EzjgAqtHkth/Iflqg==
Final Action Date2021-07-13
Application PurposeOriginal Equipment
Applicant FRN0030076269
Model5GMNN261
Frequency Range27550.08-28299.96 MHz
Equipment Class5GB - Part 30 Fixed Transmitter
Device DescriptionVerizon Auto-Certification Platform - 5G MM 28GHz
Responsible PartyAnuradha Gupta, CEO, anuradha@amantyatech.com , 3022739329
Technical ContactJim Tsai, SPORTON INTERNATIONAL (KUNSHAN) INC, JimTsai@Sporton.com.tw , +86-512-5790-0158
Test FirmAlex Chen, SPORTON International Inc., alex@sporton.com.tw , 886-3-327-3456
TCB EmailKevinLu@sporton-usa.com
TCB ScopeB4: Microwave, Millimeter Wave Band and Citizens Broadband Radio Services equipment in 47 CFR Parts 25, 30, 74, 90, 95, 96, 97, 101 (all above 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsProfessional installation is required for fixed-mounted indoor operation in commercial/business premises excluding private resident/property. Power output is EIRP Density per 100 MHz. This transmitter uses up to 2X2 MIMO. The antenna(s) must be installed to provide at least 87cm separation distance from all person to comply with the General Population / Uncontrolled MPE limit and requirements. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s) including mitigation actions for fixed RF sources to the extent necessary to ensure compliance with FCC exposure limits per section §1.1307(b)(4). This device supports Frequency Range 2 5G NR modes of 100 MHz bandwidth modes for n261. This device also supports n261 uplink carrier aggregation (2CC, 4CC) as described in this filing.

Applications

Application IDDatePurpose
C+Vf7EzjgAqtHkth/Iflqg==2021-07-13Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
27550.08-28299.96 MHz92.682.5ppm399MG7D3EP, MO
27550.08-28299.96 MHz56.622.5ppm389MW7D3EP, MO
27550.08-28299.96 MHz93.762.5ppm195MG7D3EP, MO
27550.08-28299.96 MHz57.542.5ppm191MW7D3EP, MO

Grants

TCB Grant - Application C+Vf7EzjgAqtHkth/Iflqg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Sporton International (USA) Inc.
1175 Montague Expressway
Milpitas, CA 95035
Date of Grant: 07/13/2021

Application Dated: 06/25/2021
Amantya Technologies, Inc
2803, Philadelphia Pike, Suite B 304
Claymont, DE 19703
 
Attention: Anuradha Gupta , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AXSZ5GMNN261
Name of Grantee:  Amantya Technologies, Inc
Equipment Class: Part 30 Fixed Transmitter
Notes: Verizon Auto-Certification Platform - 5G MM 28GHz
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 30 27550.08  -  28299.96 92.68 2.5  PM 399MG7D
EP MO 30 27550.08  -  28299.96 56.62 2.5  PM 389MW7D
EP MO 30 27550.08  -  28299.96 93.76 2.5  PM 195MG7D
EP MO 30 27550.08  -  28299.96 57.54 2.5  PM 191MW7D

Professional installation is required for fixed-mounted indoor operation in commercial/business premises excluding private resident/property. Power output is EIRP Density per 100 MHz. This transmitter uses up to 2X2 MIMO. The antenna(s) must be installed to provide at least 87cm separation distance from all person to comply with the General Population / Uncontrolled MPE limit and requirements. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s) including mitigation actions for fixed RF sources to the extent necessary to ensure compliance with FCC exposure limits per section §1.1307(b)(4). This device supports Frequency Range 2 5G NR modes of 100 MHz bandwidth modes for n261. This device also supports n261 uplink carrier aggregation (2CC, 4CC) as described in this filing.

EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application C+Vf7EzjgAqtHkth/Iflqg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Amantya Technologies, Inc
2803, Philadelphia Pike, Suite B 304
Claymont, DE 19703
United States
  Date of Grant: 07/13/2021

Application Dated: 06/25/2021
 
Attention: Anuradha Gupta , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AXSZ5GMNN261
Name of Grantee:  Amantya Technologies, Inc
Equipment Class: Part 30 Fixed Transmitter
Notes: Verizon Auto-Certification Platform - 5G MM 28GHz
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 30 27550.08  -  28299.96 92.68 2.5  PM 399MG7D
EP MO 30 27550.08  -  28299.96 56.62 2.5  PM 389MW7D
EP MO 30 27550.08  -  28299.96 93.76 2.5  PM 195MG7D
EP MO 30 27550.08  -  28299.96 57.54 2.5  PM 191MW7D

Professional installation is required for fixed-mounted indoor operation in commercial/business premises excluding private resident/property. Power output is EIRP Density per 100 MHz. This transmitter uses up to 2X2 MIMO. The antenna(s) must be installed to provide at least 87cm separation distance from all person to comply with the General Population / Uncontrolled MPE limit and requirements. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s) including mitigation actions for fixed RF sources to the extent necessary to ensure compliance with FCC exposure limits per section §1.1307(b)(4). This device supports Frequency Range 2 5G NR modes of 100 MHz bandwidth modes for n261. This device also supports n261 uplink carrier aggregation (2CC, 4CC) as described in this filing.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: