FCC ID 2AXVJFORCE3-PSB
Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS
by TowerIQ, Inc.
Grantee Code: 2AXVJ Product Code: FORCE3PSB
Latest application date: 2021-04-20
FCC ID Device Details
| FCC ID | 2AXVJFORCE3-PSB |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AXVJ |
| Product Code | FORCE3PSB |
| Applicant Business | TowerIQ, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Test Firm | CKC Laboratories, Inc. |
Linked Records
Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.
| UPC / GTIN | Linked product |
|---|---|
| 857593005369 UPC-A · GTIN-14 00857593005369 | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS Brand: TowerIQ, Inc. · Model: FORCE3PSB Source: FCC label |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 817-824 MHz | Change in identification of presently authorized equipment. Original FCC ID: RSNFORCE3-PSB Grant Date: 06/17/2015 | 2021-04-20 |
| 758-768 MHz | Change in identification of presently authorized equipment. Original FCC ID: RSNFORCE3-PSB Grant Date: 06/17/2015 | 2021-04-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Images | External Photos | 2021-04-20 | PDF 293.2 KB |
| Force 3 Label | ID Label/Location Info | 2021-04-20 | PDF 104 KB |
| Label Location | ID Label/Location Info | 2021-04-20 | PDF 120.2 KB |
| Change in ID Cover Letter | Cover Letter(s) | 2021-04-20 | PDF 210 KB |
| POA Letter | Cover Letter(s) | 2021-04-20 | PDF 238.9 KB |
| Permission Letter | Cover Letter(s) | 2021-04-20 | PDF 111.9 KB |
Application Information
| Application ID | At1vCBW5ZnKUu8A4igNt/A== |
|---|---|
| Final Action Date | 2021-04-20 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: RSNFORCE3-PSB Grant Date: 06/17/2015 |
| Applicant FRN | 0030092514 |
| Model | FORCE3-PSB |
| Frequency Range | 817-824 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Responsible Party | Michael McIsaac, Regulatory Engineer, michaelm@pottersignal.com |
| Test Firm | Steve Behm, CKC Laboratories, Inc., qa@ckc.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| At1vCBW5ZnKUu8A4igNt/A== | 2021-04-20 | Change in identification of presently authorized equipment. Original FCC ID: RSNFORCE3-PSB Grant Date: 06/17/2015 |
| AQ1xpgieRS+Q/ZCVWZstCw== | 2021-04-20 | Change in identification of presently authorized equipment. Original FCC ID: RSNFORCE3-PSB Grant Date: 06/17/2015 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 758-768 MHz | 0.61 | Amp | G7D | 9 | PF |
| 769-775 MHz | 0.52 | Amp | F1D | 9 | |
| 799-805 MHz | 0.5 | Amp | F1D | 9 | |
| 806-817 MHz | 0.43 | Amp | F1D | 9 | |
| 806-817 MHz | 0.42 | Amp | F3E | 9 | |
| 817-824 MHz | 0.35 | Amp | D1W | 90S | |
| 851-862 MHz | 0.49 | Amp | F1D | 9 | |
| 851-862 MHz | 0.49 | Amp | F3E | 9 | |
| 862-869 MHz | 0.35 | Amp | D1W | 90S | |
| 896-901 MHz | 0.4 | Amp | F3E | 90S | |
| 896-901 MHz | 0.4 | Amp | F3E | 9 | |
| 935-940 MHz | 0.49 | Amp | F3E | 9 | |
| 935-940 MHz | 0.49 | Amp | F3E | 90S |
Grants
TCB Grant - Application At1vCBW5ZnKUu8A4igNt/A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| TowerIQ, Inc. |
| 13723 Riverport Drive |
| C/O Potter Electric Signal Company |
| Saint Louis, MO 63043 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJFORCE3-PSB |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90S | 817.0 - 824.0 | 0.35 | Amp | D1W | |
| 90S | 862.0 - 869.0 | 0.35 | Amp | D1W | |
| 90S | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
EAS Grant - Application At1vCBW5ZnKUu8A4igNt/A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TowerIQ, Inc. 13723 Riverport Drive C/O Potter Electric Signal Company Saint Louis, MO 63043 United States |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJFORCE3-PSB |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90S | 817.0 - 824.0 | 0.35 | Amp | D1W | |
| 90S | 862.0 - 869.0 | 0.35 | Amp | D1W | |
| 90S | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| TowerIQ, Inc. |
| 13723 Riverport Drive |
| C/O Potter Electric Signal Company |
| Saint Louis, MO 63043 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJFORCE3-PSB |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.39 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.5 | Amp | F1D | |
| PF | 90 | 758.0 - 768.0 | 0.61 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.52 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.43 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.42 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F3E | |
| 90 | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application AQ1xpgieRS+Q/ZCVWZstCw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TowerIQ, Inc. 13723 Riverport Drive C/O Potter Electric Signal Company Saint Louis, MO 63043 United States |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJFORCE3-PSB |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.39 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.5 | Amp | F1D | |
| PF | 90 | 758.0 - 768.0 | 0.61 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.52 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.43 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.42 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F3E | |
| 90 | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: |