FCC ID 2AXVJGUARD-2QR
Dual band public safety signal booster
by TowerIQ, Inc.
Grantee Code: 2AXVJ Product Code: GUARD2QR
Latest application date: 2021-04-20
FCC ID Device Details
| FCC ID | 2AXVJGUARD-2QR |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AXVJ |
| Product Code | GUARD2QR |
| Applicant Business | TowerIQ, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Dual band public safety signal booster |
| Test Firm | CKC Laboratories, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-768 MHz | Change in identification of presently authorized equipment. Original FCC ID: RSNGUARD-2QR Grant Date: 07/18/2018 | 2021-04-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2021-04-20 | PDF 230.1 KB |
| label | ID Label/Location Info | 2021-04-20 | PDF 90.4 KB |
| label location | ID Label/Location Info | 2021-04-20 | PDF 88 KB |
| Change of ID Request Letter | Cover Letter(s) | 2021-04-20 | PDF 118.1 KB |
| POA | Cover Letter(s) | 2021-04-20 | PDF 194.8 KB |
| Permission Letter | Cover Letter(s) | 2021-04-20 | PDF 110.9 KB |
Application Information
| Application ID | PO06ckvuqZsj9+DkYCzGEg== |
|---|---|
| Final Action Date | 2021-04-20 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: RSNGUARD-2QR Grant Date: 07/18/2018 |
| Applicant FRN | 0030092514 |
| Model | GUARD-2QR |
| Frequency Range | 758-768 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | Dual band public safety signal booster |
| Responsible Party | Michael McIsaac, Regulatory Engineer, michaelm@pottersignal.com |
| Test Firm | Steve Behm, CKC Laboratories, Inc., qa@ckc.com |
| TCB Email | TEI@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| PO06ckvuqZsj9+DkYCzGEg== | 2021-04-20 | Change in identification of presently authorized equipment. Original FCC ID: RSNGUARD-2QR Grant Date: 07/18/2018 |
Equipment Authorization
Grants
TCB Grant - Application PO06ckvuqZsj9+DkYCzGEg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| TowerIQ, Inc. |
| 13723 Riverport Drive |
| C/O Potter Electric Signal Company |
| Saint Louis, MO 63043 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJGUARD-2QR |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Dual band public safety signal booster |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.3388 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.3548 | Amp | F1D | |
| 90 | 806.0 - 816.0 | 0.3631 | Amp | F1D | |
| 90 | 808.0 - 816.0 | 0.3631 | Amp | F3E | |
| PF | 90 | 758.0 - 768.0 | 0.2399 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.2042 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 0.4365 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 0.4365 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application PO06ckvuqZsj9+DkYCzGEg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TowerIQ, Inc. 13723 Riverport Drive C/O Potter Electric Signal Company Saint Louis, MO 63043 United States |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJGUARD-2QR |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Dual band public safety signal booster |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.3388 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.3548 | Amp | F1D | |
| 90 | 806.0 - 816.0 | 0.3631 | Amp | F1D | |
| 90 | 808.0 - 816.0 | 0.3631 | Amp | F3E | |
| PF | 90 | 758.0 - 768.0 | 0.2399 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.2042 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 0.4365 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 0.4365 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: |