FCC ID 2AXVJPSBG-2AUL
something appropriate based on the application information. In-building 2-Way Emergency Radio Communication Enhancement Booster
by TowerIQ, Inc.
Grantee Code: 2AXVJ Product Code: PSBG2AUL
Latest application date: 2021-09-30
FCC ID Device Details
| FCC ID | 2AXVJPSBG-2AUL |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AXVJ |
| Product Code | PSBG2AUL |
| Applicant Business | TowerIQ, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | something appropriate based on the application information. In-building 2-Way Emergency Radio Communication Enhancement Booster |
| Test Firm | GUANGZHOU GRG METROLOGY & TEST CO., LTD |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 769-775 MHz | Original Equipment | 2021-09-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual rev_01 Metadata only | Users Manual | 2021-09-30 | PDF 1.6 MB |
| User Manual rev_02 | Users Manual | 2021-09-30 | PDF 1.6 MB |
| Internal photos | Internal Photos | 2021-09-30 | PDF 1.2 MB |
| External photos | External Photos | 2021-09-30 | PDF 268.6 KB |
| Label info | ID Label/Location Info | 2021-09-30 | PDF 130.9 KB |
| Test setup photos | Test Setup Photos | 2021-09-30 | PDF 247.6 KB |
| Test report page 1-50 final | Test Report | 2021-09-30 | PDF 4.2 MB |
| Test report page 101-125 final | Test Report | 2021-09-30 | PDF 3.2 MB |
| Test report page 126-150 final | Test Report | 2021-09-30 | PDF 3.2 MB |
| Test report page 151-200 final | Test Report | 2021-09-30 | PDF 5.1 MB |
| Test report page 201-250 final | Test Report | 2021-09-30 | PDF 4.9 MB |
| Test report page 251-282 final | Test Report | 2021-09-30 | PDF 2.3 MB |
| Test report page 51-100 final | Test Report | 2021-09-30 | PDF 5 MB |
| LETTER OF ATTESTATION | Cover Letter(s) | 2021-09-30 | PDF 118 KB |
| Authority to Act as Agent | Cover Letter(s) | 2021-09-30 | PDF 23.9 KB |
| Declaration letter | Cover Letter(s) | 2021-09-30 | PDF 22.2 KB |
| Declaration of conformity | Cover Letter(s) | 2021-09-30 | PDF 16.1 KB |
| Request for Confidentiality | Cover Letter(s) | 2021-09-30 | PDF 371.1 KB |
| MPE report final | RF Exposure Info | 2021-09-30 | PDF 3.4 MB |
| Block Diagram Metadata only | Block Diagram | PDF 300.2 KB | |
| Schematic 1 Metadata only | Schematics | PDF 1.2 MB | |
| Schematic 2 Metadata only | Schematics | PDF 3.6 MB | |
| Schematic 3 Metadata only | Schematics | PDF 244.4 KB | |
| Operation description rev_01 Metadata only | Operational Description | PDF 790.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 184.6 KB | |
| Tune-up procedure rev_01 Metadata only | Parts List/Tune Up Info | PDF 905.1 KB | |
| Tune-up procedure rev_02 Metadata only | Parts List/Tune Up Info | PDF 944.7 KB |
Application Information
| Application ID | HMT25y92GqauGNRVWv9SVg== |
|---|---|
| Final Action Date | 2021-09-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030092514 |
| Model | PSBG-2AUL |
| Frequency Range | 769-775 MHz |
| Equipment Class | B9A - Part 90 Class A Industrial Booster (non-SMR) |
| Device Description | something appropriate based on the application information. In-building 2-Way Emergency Radio Communication Enhancement Booster |
| Responsible Party | Michael McIsaac, Regulatory Engineer, michaelm@pottersignal.com |
| Agent | Krystal Krystal Krystal, Guangzhou GRG Metrology and Test CO., LTD., yanghy2@grgtest.com |
| Technical Contact | Krystal Yang, Guangzhou GRG Metrology and Test CO., LTD., yanghy2@grgtest.com |
| Test Firm | Nancy Dai, GUANGZHOU GRG METROLOGY & TEST CO., LTD, szgrgt@grgtest.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class A signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 2 dBi for downlink and 9 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.2 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| HMT25y92GqauGNRVWv9SVg== | 2021-09-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 769-775 MHz | 2.041 | Amp | F1E | 9 |
| 769-775 MHz | 2.041 | Amp | F1D | 9 |
| 769-775 MHz | 2.041 | Amp | F1W | 9 |
| 799-805 MHz | 0.398 | Amp | F3E | 9 |
| 799-805 MHz | 0.398 | Amp | F1E | 9 |
| 799-805 MHz | 0.398 | Amp | F1D | 9 |
| 799-805 MHz | 0.398 | Amp | F1W | 9 |
| 806-816 MHz | 0.589 | Amp | F3E | 9 |
| 806-816 MHz | 0.49 | Amp | F1E | 9 |
| 806-816 MHz | 0.49 | Amp | F1D | 9 |
| 806-816 MHz | 0.49 | Amp | F1W | 9 |
| 851-861 MHz | 2.818 | Amp | F1E | 9 |
| 851-861 MHz | 2.818 | Amp | F1D | 9 |
| 851-861 MHz | 2.818 | Amp | F1W | 9 |
| 851-861 MHz | 2.818 | Amp | F3E | 9 |
Grants
TCB Grant - Application HMT25y92GqauGNRVWv9SVg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 09/30/2021 Application Dated: 09/29/2021 |
| TowerIQ, Inc. |
| 13723 Riverport Drive |
| C/O Potter Electric Signal Company |
| Saint Louis, MO 63043 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJPSBG-2AUL |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class A Industrial Booster (non-SMR) |
| Notes: | something appropriate based on the application information. In-building 2-Way Emergency Radio Communication Enhancement Booster |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F3E | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1D | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1W | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F3E | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1E | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1D | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1W | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F3E | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1E | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1W | |
| 90 | 806.0 - 816.0 | 0.589 | Amp | F3E | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1E | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1W |
| Class A signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 2 dBi for downlink and 9 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.2 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application HMT25y92GqauGNRVWv9SVg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TowerIQ, Inc. 13723 Riverport Drive C/O Potter Electric Signal Company Saint Louis, MO 63043 United States |
Date of Grant: 09/30/2021 Application Dated: 09/29/2021 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJPSBG-2AUL |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class A Industrial Booster (non-SMR) |
| Notes: | something appropriate based on the application information. In-building 2-Way Emergency Radio Communication Enhancement Booster |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F3E | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1D | |
| 90 | 769.0 - 775.0 | 2.041 | Amp | F1W | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F3E | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1E | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1D | |
| 90 | 799.0 - 805.0 | 0.398 | Amp | F1W | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F3E | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1E | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1D | |
| 90 | 851.0 - 861.0 | 2.818 | Amp | F1W | |
| 90 | 806.0 - 816.0 | 0.589 | Amp | F3E | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1E | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 816.0 | 0.49 | Amp | F1W |
| Class A signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 2 dBi for downlink and 9 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.2 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |