FCC ID 2AXVJPSBG-2BUL
In-Building 2-Way Emergency Radio Communication Enhancement Booster
by TowerIQ, Inc.
Grantee Code: 2AXVJ Product Code: PSBG2BUL
Latest application date: 2021-04-20
FCC ID Device Details
| FCC ID | 2AXVJPSBG-2BUL |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AXVJ |
| Product Code | PSBG2BUL |
| Applicant Business | TowerIQ, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | In-Building 2-Way Emergency Radio Communication Enhancement Booster |
| Test Firm | Guangzhou GRG Metrology & Test Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-768 MHz | Change in identification of presently authorized equipment. Original FCC ID: RSNPSBG-2BUL Grant Date: 03/04/2021 | 2021-04-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2021-04-20 | PDF 1.8 MB |
| Label and label location | ID Label/Location Info | 2021-04-20 | PDF 311.3 KB |
| Change of ID Request Letter | Cover Letter(s) | 2021-04-20 | PDF 117.5 KB |
| POA | Cover Letter(s) | 2021-04-20 | PDF 109.5 KB |
| Permission Letter | Cover Letter(s) | 2021-04-20 | PDF 227.7 KB |
Application Information
| Application ID | CM1PpEUHz1OuH0QJxr/P5Q== |
|---|---|
| Final Action Date | 2021-04-20 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: RSNPSBG-2BUL Grant Date: 03/04/2021 |
| Applicant FRN | 0030092514 |
| Model | PSBG-2BUL |
| Frequency Range | 758-768 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | In-Building 2-Way Emergency Radio Communication Enhancement Booster |
| Responsible Party | Michael McIsaac, Regulatory Engineer, michaelm@pottersignal.com |
| Test Firm | Frank Chen, Guangzhou GRG Metrology & Test Co., Ltd., frank.chen@grgtest.com |
| TCB Email | TEI@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class B signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 3 dBi for downlink and 6 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.43 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| CM1PpEUHz1OuH0QJxr/P5Q== | 2021-04-20 | Change in identification of presently authorized equipment. Original FCC ID: RSNPSBG-2BUL Grant Date: 03/04/2021 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 769-775 MHz | 1.919 | Amp | F1E | 9 | |
| 769-775 MHz | 1.919 | Amp | G1E | 9 | |
| 769-775 MHz | 1.919 | Amp | F3E | 9 | |
| 788-798 MHz | 1.14 | Amp | G7D | 9 | PF |
| 799-805 MHz | 0.946 | Amp | F1E | 9 | |
| 799-805 MHz | 0.946 | Amp | G1E | 9 | |
| 799-805 MHz | 0.946 | Amp | F3E | 9 | |
| 806-816 MHz | 1.062 | Amp | F1E | 9 | |
| 806-816 MHz | 1.062 | Amp | G1E | 9 | |
| 806-816 MHz | 1.062 | Amp | F3E | 9 | |
| 851-861 MHz | 1.959 | Amp | G1E | 9 | |
| 851-861 MHz | 1.959 | Amp | F3E | 9 | |
| 851-861 MHz | 1.959 | Amp | F1E | 9 |
Grants
TCB Grant - Application CM1PpEUHz1OuH0QJxr/P5Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| TowerIQ, Inc. |
| 13723 Riverport Drive |
| C/O Potter Electric Signal Company |
| Saint Louis, MO 63043 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJPSBG-2BUL |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | In-Building 2-Way Emergency Radio Communication Enhancement Booster |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 2.009 | Amp | G7D |
| PF | 90 | 788.0 - 798.0 | 1.14 | Amp | G7D |
| 90 | 769.0 - 775.0 | 1.919 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 1.919 | Amp | G1E | |
| 90 | 769.0 - 775.0 | 1.919 | Amp | F3E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | F1E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | G1E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | F3E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | F1E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | G1E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | F3E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | F1E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | G1E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | F3E |
| Class B signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 3 dBi for downlink and 6 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.43 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application CM1PpEUHz1OuH0QJxr/P5Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TowerIQ, Inc. 13723 Riverport Drive C/O Potter Electric Signal Company Saint Louis, MO 63043 United States |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Attention: Michael McIsaac , Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AXVJPSBG-2BUL |
| Name of Grantee: | TowerIQ, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | In-Building 2-Way Emergency Radio Communication Enhancement Booster |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 2.009 | Amp | G7D |
| PF | 90 | 788.0 - 798.0 | 1.14 | Amp | G7D |
| 90 | 769.0 - 775.0 | 1.919 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 1.919 | Amp | G1E | |
| 90 | 769.0 - 775.0 | 1.919 | Amp | F3E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | F1E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | G1E | |
| 90 | 799.0 - 805.0 | 0.946 | Amp | F3E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | F1E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | G1E | |
| 90 | 851.0 - 861.0 | 1.959 | Amp | F3E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | F1E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | G1E | |
| 90 | 806.0 - 816.0 | 1.062 | Amp | F3E |
| Class B signal booster. Power output is conducted. The intended use is for industrial/commercial use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor structures, and may not have gain exceeding 3 dBi for downlink and 6 dBi for uplink. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 88.43 cm from all persons and must not transmit simultaneously with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: |