FCC ID 2AY3N-2D00

TUBE THERMAL IMAGING SCOPE, TUBE THERMAL IMAGING SIGHT

by InfiRay Technologies Co., Ltd.

Grantee Code: 2AY3N   Product Code: 2D00
Latest application date: 2024-10-21

FCC ID Device Details

FCC ID2AY3N-2D00
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AY3N
Product Code2D00
Applicant BusinessInfiRay Technologies Co., Ltd. 🇨🇳
Related Domains infiray.com
Equipment ClassTUBE THERMAL IMAGING SCOPE, TUBE THERMAL IMAGING SIGHT
Test FirmCCIC Southern Testing Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2024-10-21
2402-2480 MHzOriginal Equipment2024-08-07
2412-2462 MHzOriginal Equipment2024-08-07

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2024-10-21PDF 4.6 MB
User Manual1Users Manual2024-08-07PDF 6 MB
User Manual2Users Manual2024-08-07PDF 706.4 KB
Internal PhotosInternal Photos2024-10-21PDF 5.6 MB
Internal PhotosInternal Photos2024-08-07PDF 2.4 MB
External PhotographExternal Photos2024-10-21PDF 5 MB
External photosExternal Photos2024-08-07PDF 947.2 KB
Label&LocationID Label/Location Info2024-10-21PDF 430.6 KB
LabelID Label/Location Info2024-08-07PDF 289.4 KB
T Setup photos SARTest Setup Photos2024-10-21PDF 154.1 KB
TEST SETUP PHOTOSTest Setup Photos2024-10-21PDF 265 KB
Appendix D SAR Test SetupTest Setup Photos2024-08-07PDF 120.4 KB
Test Setup PhotoTest Setup Photos2024-08-07PDF 452.9 KB
Test Setup PhotosTest Setup Photos2024-08-07PDF 452.9 KB
Antenna InformationTest Report2024-10-21PDF 275.3 KB
Test ReportTest Report2024-10-21PDF 2.3 MB
Test Report SARRF Exposure Info2024-10-21PDF 1.1 MB
ANT SpecTest Report2024-08-07PDF 266.3 KB
Test Report Metadata onlyTest Report2024-08-07PDF 452.9 KB
Test Report 2.4g WiFiTest Report2024-08-07PDF 3.4 MB
Test Report BTTest Report2024-08-07PDF 4.4 MB
Test Report SARRF Exposure Info2024-08-07PDF 594.4 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2024-10-21PDF 71.9 KB
2.911 (d)(7)USAgentforServiceofProcessv1.2Attestation Statements2024-10-21PDF 138.8 KB
2.911_(d)(5)(ii) Certification Equipment Type v1.2_Revision 01Attestation Statements2024-10-21PDF 93 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2024-08-07PDF 85 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2024-08-07PDF 164.1 KB
2.911 (d)(7) US Agent for Service of Process v1.4Attestation Statements2024-08-07PDF 81.3 KB
FCC Long&shortTermOnlyConfidentialityRequestRev4.0Cover Letter(s)2024-10-21PDF 73.4 KB
Letter of Authorization Rev 1.0Cover Letter(s)2024-10-21PDF 74.4 KB
model different letterCover Letter(s)2024-10-21PDF 143.9 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2024-08-07PDF 86.9 KB
Letter of Authorization Rev 2.0Cover Letter(s)2024-08-07PDF 236.9 KB
Model DifferenceCover Letter(s)2024-08-07PDF 19.4 KB
Appendix A SAR System performance Check PlotsRF Exposure Info2024-10-21PDF 96.7 KB
Appendix B SAR Measurement results PlotsRF Exposure Info2024-10-21PDF 20 KB
Appendix C Calibration reportsRF Exposure Info2024-10-21PDF 1.1 MB
Appendix A SAR System performance Check PlotsRF Exposure Info2024-08-07PDF 120.5 KB
Appendix B SAR Measurement results PlotsRF Exposure Info2024-08-07PDF 104.6 KB
Appendix C Calibration reportsRF Exposure Info2024-08-07PDF 1.1 MB
Block Metadata onlyBlock DiagramPDF 178.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 208.5 KB
SCH Metadata onlySchematicsPDF 1.1 MB
SCH Metadata onlySchematicsPDF 1.6 MB
OP Metadata onlyOperational DescriptionPDF 93.3 KB
OP Metadata onlyOperational DescriptionPDF 99.5 KB

Application Information

Application IDOSoTCvpZ9j8jgSC6JSmuCQ==
Final Action Date2024-10-21
Application PurposeOriginal Equipment
Applicant FRN0030643415
Model2D00
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionTUBE THERMAL IMAGING SCOPE, TUBE THERMAL IMAGING SIGHT
Responsible PartyXueyan Fu, xueyan.fu@infiray.com , 086-15064097026
Technical ContactInfiRay Technologies Co., Ltd., xueyan.fu@infiray.com
Test FirmChris You, CCIC Southern Testing Co., Ltd, youxj@ccic-set.com , 86-0755-86131239
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.56 W/kg.

Applications

Application IDDatePurpose
OSoTCvpZ9j8jgSC6JSmuCQ==2024-10-21Original Equipment
M2fo+i729FobvmyLjMxu8Q==2024-08-07Original Equipment
1msqo8y4b3tZQX1kxwOArA==2024-08-07Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.005000015CCC
2412-2462 MHz0.024000015C
2412-2462 MHz0.042800015C

Grants

TCB Grant - Application OSoTCvpZ9j8jgSC6JSmuCQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 10/21/2024

Application Dated: 10/21/2024
InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road,
National High-tech Industry Development District,
Hefei, Anhui,
China
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: TUBE THERMAL IMAGING SCOPE, TUBE THERMAL IMAGING SIGHT
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0428  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.56 W/kg.

EAS Grant - Application OSoTCvpZ9j8jgSC6JSmuCQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road, National High-tech Industry Development District,
Hefei, Anhui,
China
  Date of Grant: 10/21/2024

Application Dated: 10/21/2024
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: TUBE THERMAL IMAGING SCOPE, TUBE THERMAL IMAGING SIGHT
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0428  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.56 W/kg.



TCB Grant - Application M2fo+i729FobvmyLjMxu8Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/07/2024

Application Dated: 08/07/2024
InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road,
National High-tech Industry Development District,
Hefei, Anhui,
China
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D-00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: TUBE Thermal Imaging Scope
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.005  

Power listed is the maximum conducted output power.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application M2fo+i729FobvmyLjMxu8Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road, National High-tech Industry Development District,
Hefei, Anhui,
China
  Date of Grant: 08/07/2024

Application Dated: 08/07/2024
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D-00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: TUBE Thermal Imaging Scope
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.005  

Power listed is the maximum conducted output power.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 1msqo8y4b3tZQX1kxwOArA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/07/2024

Application Dated: 08/07/2024
InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road,
National High-tech Industry Development District,
Hefei, Anhui,
China
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D-00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: TUBE Thermal Imaging Scope
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.024  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.07 W/kg.

EAS Grant - Application 1msqo8y4b3tZQX1kxwOArA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

InfiRay Technologies Co., Ltd.
Building C3, NO.800 Wangjiang West Road, National High-tech Industry Development District,
Hefei, Anhui,
China
  Date of Grant: 08/07/2024

Application Dated: 08/07/2024
 
Attention: Xueyan Fu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY3N-2D-00
Name of Grantee:  InfiRay Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: TUBE Thermal Imaging Scope
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.024  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.07 W/kg.



Mail To: