FCC ID 2AY7J-INSPIRE2

3D Scanner

by Revopoint 3D Technologies Inc.

Grantee Code: 2AY7J   Product Code: INSPIRE2
Latest application date: 2025-12-11

FCC ID Device Details

FCC ID2AY7J-INSPIRE2
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AY7J
Product CodeINSPIRE2
Applicant BusinessRevopoint 3D Technologies Inc. 🇨🇳
Related Domains chishine3d.com
Equipment Class3D Scanner
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5260-5320 MHzOriginal Equipment2025-12-11

Exhibits

DocumentTypeAvailableFile
User Manual_part_1Users Manual2026-06-09PDF 2.1 MB
User Manual_part_2Users Manual2026-06-09PDF 2.2 MB
User Manual_part_3Users Manual2026-06-09PDF 2.8 MB
User Manual_part_4Users Manual2026-06-09PDF 2.8 MB
User Manual_part_5Users Manual2026-06-09PDF 3 MB
User Manual_part_6Users Manual2026-06-09PDF 2.4 MB
Internal PhotosInternal Photos2026-06-09PDF 1.8 MB
External photosExternal Photos2026-06-09PDF 1,020.4 KB
LabelID Label/Location Info2025-12-11PDF 835.6 KB
Appendix A.EUT Photos and Test Setup PhotosTest Setup Photos2026-06-09PDF 415.7 KB
Test Setup Photos_RFTest Setup Photos2026-06-09PDF 660.3 KB
Antenna ReportTest Report2025-12-11PDF 1.4 MB
Appendix Data RLAN Part 1Test Report2025-12-11PDF 5.5 MB
Appendix Data RLAN Part 2Test Report2025-12-11PDF 5.3 MB
SAR Test ReportRF Exposure Info2025-12-11PDF 2.1 MB
Test ReportTest Report2025-12-11PDF 3.7 MB
Attestation Statements-KasperskyAttestation Statements2025-12-11PDF 145.3 KB
Attestation Statements-Not Covered ApplicantAttestation Statements2025-12-11PDF 67.4 KB
US AgentAttestation Statements2025-12-11PDF 1.1 MB
Confidentiality RequestCover Letter(s)2025-12-11PDF 127.3 KB
Model Difference DescriptionCover Letter(s)2025-12-11PDF 75.5 KB
POACover Letter(s)2025-12-11PDF 42.6 KB
Software Configuration Control DeclarationCover Letter(s)2025-12-11PDF 67.2 KB
Appendix B.Plots of SAR System CheckRF Exposure Info2025-12-11PDF 332.5 KB
Appendix C.Plots of SAR Test DataRF Exposure Info2025-12-11PDF 1.2 MB
Appendix D.DASY System Calibration CertificateRF Exposure Info2025-12-11PDF 5.1 MB
Block Diagram Metadata onlyBlock DiagramPDF 568.7 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operation Description Metadata onlyOperational DescriptionPDF 93.1 KB
NII Security request Metadata onlySDR Software/Security Info.PDF 91.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 175.9 KB

Application Information

Application ID3MN+biLDLlh3jpZ560ehxg==
Final Action Date2025-12-11
Application PurposeOriginal Equipment
Applicant FRN0030680961
ModelINSPIRE2
Frequency Range5260-5320 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description3D Scanner
Responsible PartyYali Liu, lyl@chishine3d.com , +86-18161739259
Test FirmJeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com , 86-12798230942
TCB Emailjoe_chew@derycom-us.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
3MN+biLDLlh3jpZ560ehxg==2025-12-11Original Equipment

Equipment Authorization

FrequencyOutputRules
5180-5240 MHz0.05715E
5260-5320 MHz0.048315E

Grants

TCB Grant - Application 3MN+biLDLlh3jpZ560ehxg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DERYCOM CERTIFICATION SERVICES, INC.
1100 Falcon Avenue
Glencoe, MN 55336
Date of Grant: 12/11/2025

Application Dated: 12/11/2025
Revopoint 3D Technologies Inc.
Office 902, 9/F, Tinno Building, Tongfa South Rd,
Xili Street, Nanshan District
Shenzhen,
China
 
Attention: Yali Liu , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AY7J-INSPIRE2
Name of Grantee:  Revopoint 3D Technologies Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 3D Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5180.0  -  5240.0 0.057  
15E 5260.0  -  5320.0 0.0483  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-carry configurations is limited to provision at least 5 mm separation between the device and the user's body. The highest reported SAR values for the body-worn and Hand (10-g extremity SAR) use conditions are 0.84 W/kg and 1.25 W/kg respectively.