FCC ID 2AYGR-3004

Evoke Clinical System Transceiver

by SALUDA MEDICAL PTY LIMITED

Grantee Code: 2AYGR   Product Code: 3004
Latest application date: 2022-05-23

FCC ID Device Details

FCC ID2AYGR-3004
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYGR
Product Code3004
Applicant BusinessSALUDA MEDICAL PTY LIMITED 🇦🇺
Related Domains saludamedical.com
Equipment ClassEvoke Clinical System Transceiver
Test FirmBureau Veritas CPS(H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
402-405 MHzOriginal Equipment2022-05-23

Exhibits

DocumentTypeAvailableFile
Users Manual(1)_Evoke-Z SCS revUsers Manual2022-11-19PDF 4.2 MB
Users Manual(2)_Evoke SCS revUsers Manual2022-11-19PDF 3.6 MB
External PhotosExternal Photos2022-11-19PDF 492.2 KB
Label LocationID Label/Location Info2022-05-23PDF 518.6 KB
Label SampleID Label/Location Info2022-05-23PDF 346 KB
Test setup photosTest Setup Photos2022-11-19PDF 235.1 KB
Test report (Part 95I) rev2Test Report2022-05-23PDF 1.3 MB
Confidentiality Request - One Way (Saluda) -NDACover Letter(s)2022-05-23PDF 134.2 KB
Confidentiality request (Long term & Short term) revCover Letter(s)2022-05-23PDF 298.6 KB
Cover Letter (Agent Authorization)Cover Letter(s)2022-05-23PDF 475.8 KB
RF Exposure Info (MPE)RF Exposure Info2022-05-23PDF 180.9 KB
Internal Photos Metadata onlyInternal PhotosPDF 613.6 KB
Block diagram Metadata onlyBlock DiagramPDF 1.7 MB
Schematics Metadata onlySchematicsPDF 750.9 KB
Schematics_RF Metadata onlySchematicsPDF 1.1 MB
Schematics_System Metadata onlySchematicsPDF 351.1 KB
Operational Description Metadata onlyOperational DescriptionPDF 340.7 KB
Parts List rev Metadata onlyParts List/Tune Up InfoPDF 719.9 KB
Tune Up Procedure rev Metadata onlyParts List/Tune Up InfoPDF 229.4 KB

Application Information

Application IDW3KjotV1XbGAGzZacEVL1Q==
Final Action Date2022-05-23
Application PurposeOriginal Equipment
Applicant FRN0030295968
Model3004
Frequency Range402-405 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionEvoke Clinical System Transceiver
Responsible PartyPeter Aigner, Peter.Aigner@saludamedical.com , +618405 8700
AgentAndrea Andrea Andrea, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, andrea.hsia@bureauveritas.com , 886-3-3183232
Test FirmEric Lin, Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch, eric-wp.lin@tw.bureauveritas.com , +886-3-2641570
TCB Emailcertification@nacsemc.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/19/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is maximum EIRP.

Applications

Application IDDatePurpose
W3KjotV1XbGAGzZacEVL1Q==2022-05-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
402-405 MHz0.000014010.6850000000ppm244KF1D95I

Grants

TCB Grant - Application W3KjotV1XbGAGzZacEVL1Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  North American EMC Certification Services Inc
24889 Ferguson Ave
Maple Ridge, BC,
Canada
Date of Grant: 05/23/2022

Application Dated: 05/23/2022
SALUDA MEDICAL PTY LIMITED
Saluda Medical
Ground Floor, 407 Pacific Hwy
Artarmon, NSW, 2064
Australia
 
Attention: Peter Aigner

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGR-3004
Name of Grantee:  SALUDA MEDICAL PTY LIMITED
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Evoke Clinical System Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95I 402.0  -  405.0 0.000014 10.685  PM 244KF1D

Power listed is maximum EIRP.

EAS Grant - Application W3KjotV1XbGAGzZacEVL1Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SALUDA MEDICAL PTY LIMITED
Saluda Medical Ground Floor, 407 Pacific Hwy
Artarmon, NSW, 2064
Australia
  Date of Grant: 05/23/2022

Application Dated: 05/23/2022
 
Attention: Peter Aigner

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGR-3004
Name of Grantee:  SALUDA MEDICAL PTY LIMITED
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Evoke Clinical System Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95I 402.0  -  405.0 0.000014 10.685  PM 244KF1D

Power listed is maximum EIRP.



Mail To: